Example of High Sensitivity Analysis (Fluorescein)
Due to its enhanced sensitivity (1.5x higher), weak signals can be detected with very low noise levels.
An example of the high sensitivity analysis for fluorescein is shown. The F-7100 detected fluorescence in the order of 1×10-13 mol/L (sub-picomol) compared with a blank sample (purified water); a useful calibration was obtained in the ultra-trace range.
Comparison of lamp lifetimes
With the application of the new Xe lamp and the improved lamp ignition power source, both luminance and the lamp lifetime were increased.
Increased lamp lifetime reduces operating Cost-of-Ownership and instrument service time.
3-D time scan spectrum of coumarin for environmental applications
The fast-speed scanning enables users to carry out measurements that have been difficult with conventional instruments. In this example, an isomerization process of coumarin in kerosene was traced by spectrum measurement at 2-second intervals and displayed as a 3-D time-scan spectrum. This is a new function in the F-7000.
Previously, a quick reaction which occurs within 1 minute could be measured only by using the fixed wavelength method. The F-7000 is capable of following such a quick reaction because of its fast scanning, measuring the entire wavelength range within 1 second.
Window for fluorescence intensity standardization
The variations in the fluorescence intensity over time and between instruments can be corrected. Fluorescence intensity is affected by changes in lamp brightness, room temperature, optical system, etc. The fluorescence intensity of the standard sample is measured, and the sample fluorescence intensity is converted to the fluorescence intensity relative to the standard sample. This standardization is also used for the intensity comparison between different instruments, including the analysis of humic substances in environmental water (conversion to quinine sulfate), the analysis of chlorophyll in water (conversion to fluorescein), and the specified value for reagent purity (conversion to quinine sulfate).
The XM60 / XM60-HR moisture analyzer is the low-volume instrument for customers with low sample volumes and quantities.
Our LAQUA benchtop models were developed to provide simplicity with excellent on-site usability – from operation and maintenance through to troubleshooting.
Water quality analysis is repeatedly performed in laboratories on a daily basis. Our high-end benchtop model was developed to provide simplicity with excellent on-site usability – from operation and maintenance through to troubleshooting.
The AFM100 Plus and AFM100 systems that make up this series have been designed to expand the capabilities and performance of atomic force microscopy.
You may contact our specialists by accomplishing form below.
You may contact our specialists by accomplishing form below.