When you change the leaf chamber environment—light, temperature, CO2, or H2O—the instrument adjusts to the new setpoint right away thanks to Rapid Sensing™ Technology. The fast adjustment saves time and enables you to measure a plant’s response to rapidly changing conditions.
Providing full control over water vapor, the LI-6800 can maintain humidity at any level below condensing conditions in the leaf chamber and gas analyzers.
Capable of achieving 10°C below and above ambient temperature, the LI-6800 provides fast and precise temperature control. It can control temperature at a setpoint, track the ambient temperature, or ramp the temperature up or down according to your experimental requirements.
User-adjustable flow rates—from 0 to 2.5 liters per minute—minimize response times and expand the system versatility.
The precise control of CO2 allows for faster measurements, so you can perform rapid A-Ci response curves with the Rapid A-Ci Response (RACiR™) Method (Pat. Pend.).
A gas input port enables you to subject the leaf to custom gas blends.
A unique, durable fine-wire thermocouple maintains direct contact with the leaf—to get the actual leaf temperature with every measurement.
To fill the chamber area—and easily calculate leaf area—swap in one of several interchangeable inserts for different leaf area apertures on the Clear-top chamber and on the Multiphase Flash fluorometer.
the successor to the popular 320 series XT, we provide you again a scale with ten control keys in front. These provide you and your employees an very easier operation.
The ViscoLab 4000 is a small sample viscometer which supports up to 12 different 20:1 viscosity ranges; up to 10,000 cP with several output options. The ViscoLab 4000 can display viscosity in either centipoise or centistokes, and temperature can be displayed in either C or F. This unit requires less than 2 ml of sample and produces an extremely reliable viscosity measurement.
The HF5000 builds on features from Hitachi HD-2700 dedicated STEM including Hitachi’s own fully automated aberration corrector, symmetrical dual SDD EDX and Cs-corrected SE imaging. It also incorporates the advanced TEM/STEM technologies developed in the HF series.
Alcor DTOT is suitable for several blends of diesel fuel like Pure Diesel (B0), Diesel Fuel with 7% FAME (B7) and Diesel Fuel with 20% FAME (B20). Now you can use JFTOTs proven platform to test thermal oxidation on diesel in a fast and safe way.