With the introduction of SID-A50, X-ray inspection systems has been using detectors such as Image Intensifier (I.I.) and C-MOS Flat Panel Detectors, which needs to convert X-ray into optical light first, in order to visualize X-ray.
These Indirect Conversion Method X-ray Detectors comes with multitude of issues. These problems include but not limited to; Low Sensitivity, Fuzziness, Time Degradation, Inadequate Life At Pony Industry Co., Ltd. we developed X-ray Camera which converts X-ray into electrical signal directly for the first time in the industry, rectifying devastating problems stated above.
For detailed explanation of this Brand New 3rd Generation X-ray Camera, please download the report below, which was published in Radiation Symposium in Japan.
Radiation Symposium Report on “Direct Conversion X-ray Camera SID-A50”
Characteristics
Converts X-ray into electronical signal directly via Cadmium telluride compound semiconductor. No need to convert X-ray into visible light with scintillator.
As more and more X-ray penetrate scintillator, “burn-in” effect takes place, causing detector’s sensitivity to deteriorate.
Since Direct Conversion Method X-ray camera does not have scintillator, above problem does not exist.
Ordinary X-ray detectors must convert X-ray into optical light first, then through numerous conversion before converted into electrical signal.
Inefficient conversion rate causes data to deteriorate.
Direct Conversion Method X-ray Camera SID-A50 is equipped with Cadmium Telluride compound semiconductor, which works like “X-ray Photodiode” to convert X-ray into electrical signal directly. This reduces the risk of data deterioration and minimizes image down-grade.
When X-ray penetrates scintillator inside ordinary X-ray detectors, light grows like a firefly, causing the image to be fuzzy.
Direct Conversion Method X-ray Camera’s image comes out crystal clear, due to its scintillator less structure. Compared to ordinary Indirect Conversion X-ray Detectors (C-MOS Flat Panel Detectors), SID-A50 has superb sensitivity.
=> Sensitivity is about 6 times more than that of C-MOS Flat panel Detectors. Better sensitivity means that the camera can express minute difference in X-ray dosage, and this leads directly to the dynamic expression of minimal faults and slight amount difference of solders.
Compared to ordinary X-ray detectors (C-MOS Flat Panel Detector), SID-A50 has about 5 times the life.
=> Readout electronics (C-MOS and ASIC) inside X-ray detectors are vulnerable to X-rays.
Ordinary X-ray detectors’ (C-MOS Flat Panel Detectors) C-MOS photodiode is only protected by the thin layer of scintillator. This thin scintillator can only absorb several dozen percent of X-ray. Majority of X-ray passes through, penetrating the readout electronics behind, damaging the detector itself, and ultimately ceasing its function all together.
Direct Conversion Method X-ray Detector (SID-A50) also has readout electronics which is vulnerable to X-ray, yet the Cadmium Telluride in front can absorb more than 99% of X-ray at 120kV. This greatly reduces the damage toward readout electronics, prolonging the life of the camera tremendously.
Analyze CBOD in conjunction with BOD to verify if non-compliant BOD results are due to nitrification and to obtain results more reflective of real effluent quality when under nitrifying conditions.
The U6000AT + adds a Membrane Desolvator​​ module to the standard U5000AT + Ultrasonic Nebulizer for improved reduction of solvent-based interferences, particularly for volatile organic solvents (both polar and non-polar types).
HORIBA’s unique compact meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop.
The Oils 7400 Homogenizing Autosampler allows two sample matricies to be introduced to an ICP instrument from the same system. Boasting a dual port rinse station fed by two separate peristaltic pumps, it can change between oils and coolants testing on demand.
The LAI‑2200C Plant Canopy Analyzer uses a non-destructive method to easily and accurately measure Leaf Area Index (LAI). It consistently outperforms other methods such as Ceptometry and Hemispherical Photography in terms of flexibility, advanced features, accuracy, and ease of use.
The PSA-70Xi Cloud, Pour and Freeze Point is the world’s only analyzer that performs pour, cloud and freeze point in one unit. Combining functions saves money and valuable bench space in the lab, while optimizing workflow.