Data Logger

State Data Logger

Records state changes, electronic pulses, and mechanical or electrical contact closures from external sensing devices.

Records state changes, electronic pulses, and mechanical or electrical contact closures from external sensing devices.

HOBO State Data Logger

Overview

Ideal for monitoring energy consumption, mechanical equipment operation, and water and gas flow.

Item number UX90-001M has been discontinued.

HOBO State Data Logger

Features
  • One logger with four recording modes
  • Internal reed switch can be used to determine when a door or window is open or closed
  • Compatible with a wide range of external sensors
  • Ships with 2.5 mm input cable
  • Compatible with HOBOware and HOBOware Pro software for logger setup and graphing & analysis
Specifications

Internal Sensor

Maximum State, Event, Runtime Frequency

1 Hz

Preferred Switch State

No magnet present (normally open)

External Input

External Contact Input

Electronic solid state switch closure or logic driven voltage output

Range

0 to 3 V DC (USB powered), 0 to 2.5 V DC (battery powered)

Maximum Pulse Frequency

50 Hz

Maximum State, Event, Runtime Frequency

1 Hz

Pulse, Event Lockout Time

0 to 1 second in 100 ms steps

Solid State Switch Closure

Input Low: < 10 KΩ; Input High: > 500 KΩ

Internal Weak Pull-Up

100 KΩ

Input Impedance

Solid state switch closure: 100 KΩ pull up

Logger

Resolution

Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event

Logging Rate

1 second to 18 hours, 12 minutes, 15 seconds

Memory Modes

Wrap when full or stop when full

Start Modes

Immediate, push button, date & time, or next interval

Stop Modes

When memory full, push button, or date & time

Time Accuracy

±1 minute per month at 25°C (77°F) (see Plot A)

Power Source

One 3V CR2032 lithium battery and USB cable

Battery Life

1 year, typical with logging intervals greater than 1 minute and normally open contacts

Memory

UX90-001: 128 KB (84,650 measurements, maximum)

UX90-001M: 512 KB (346,795 measurements, maximum)

Download Type

USB 2.0 interface

Full Memory Download Time

10 seconds for 128 KB; 30 seconds for 512 KB

Logger Operating Range

Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification

LCD

LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

Size

3.66 x 5.94 x 1.52 cm
1.44 x 2.34 x 0.6 in.

Weight

23 g
0.81 oz

Environmental Rating

IP50

HOBO State Data Logger

State Data Logger

For more informationcontact us.

Choose user manual language:

Choose quick start language:

Related Products

A high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads from office equipment, vending machines, and other devices.
A high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads from office equipment, vending machines, and other devices.
A weatherproof data logger with two external temperature sensors.
A weatherproof data logger with two external temperature sensors.
The LI-180 Spectrometer lets you capture the spectral composition of your light sources with a single click.
The LI-180 Spectrometer lets you capture the spectral composition of your light sources with a single click.
Low-cost, fully integrated soil moisture loggers with Bluetooth wireless data offload.
Low-cost, fully integrated soil moisture loggers with Bluetooth wireless data offload.
The LI-7500DS is designed for high-speed CO2 and water vapor measurements in ambient air. Lower power and maintenance requirements make it ideal for field deployments.
The LI-7500DS is designed for high-speed CO2 and water vapor measurements in ambient air. Lower power and maintenance requirements make it ideal for field deployments.
The LI-1500 allows for simple configuration of automated sampling to compute daily light integral (DLI) from PAR readings captured by LI-COR quantum sensors.
The LI-1500 allows for simple configuration of automated sampling to compute daily light integral (DLI) from PAR readings captured by LI-COR quantum sensors.
Monitors indoor light changes with an internal sensor and records light on/off conditions; ideal for building energy audits and light usage analysis.
Monitors indoor light changes with an internal sensor and records light on/off conditions; ideal for building energy audits and light usage analysis.
The LI-550 reports wind speed, direction, temperature, humidity, pressure, tilt, and compass data. Its size and weight make it perfect for many UAS/UAV.
The LI-550 reports wind speed, direction, temperature, humidity, pressure, tilt, and compass data. Its size and weight make it perfect for many UAS/UAV.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

State Data Logger
Data Logger
State Data Logger
Data Logger