Data Logger

4-Channel Analog Data Logger

A high-performance, LCD display data logger to measure and record temperature, current, CO2, voltage, and more, for building performance monitoring applications.

A high-performance, LCD display data logger to measure and record temperature, current, CO2, voltage, and more, for building performance monitoring applications.

4 Channel Analog Data Logger

Overview

This logger is ideal for energy audits, building commissioning studies, equipment scheduling, and more.

4 Channel Analog Data Logger

Features
  • Twice the accuracy of previous models with 16-bit resolution
  • Flexible support for a wide range of external sensors
  • LCD confirms logger operation and displays near real-time measurement data
  • Provides minimum, maximum, average, and standard deviation logging options
  • On-screen alarms notify you when a sensor reading exceeds set thresholds
  • Stores 1.9 million measurements for longer deployments between offloads
  • Compatible with HOBOware and HOBOware Pro software for logger setup and graphing & analysis

4 Channel Analog Data Logger

Specifications

Logger w/Cable

Measurement Range:
4-20mA (w/CABLE-4-20MA) 0 to 20.1 mA
0 to 2.5 V (w/CABLE-2.5-STEREO)
0 to 5 V (w/CABLE-ADAP5)
0 to 10 V (w/ CABLE-ADAP10)
0 to 24 V (w/ CABLE-ADAP24)

Accuracy:
4-20mA ±0.001 mA ±0.2% of reading (w/CABLE-4-20MA)
±0.1 mV ±0.1% of reading (w/CABLE-2.5-STEREO)
±0.2 mV ±0.3% of reading (w/CABLE-ADAP5)
±0.4 mV ±0.3% of reading (w/ CABLE-ADAP10)
±1.0 mV ±0.3% of reading(w/ CABLE-ADAP24)

Resolution:
0.3 µA 4-20mA (w/CABLE-4-20MA)
40 µV (w/CABLE-2.5-STEREO)
80 µV (w/CABLE-ADAP5)
160 µV (w/ CABLE-ADAP10)
384 µV (w/ CABLE-ADAP24)

4 Channel Analog Data Logger

Logger

Operating range logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing);
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, burst, or statistics
Memory modes: Wrap when full or stop when full
Start modes: Immediate, push button, date & time, or next interval
Stop modes: When memory full, push button, or date & time
Restart mode: Push button
Time accuracy: ±1 minute per month at 25°C (77°F), see Plot A
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery type: Two AAA 1.5 V alkaline batteries, user replaceable
Memory: 4 MB (1.9 million measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: approximately 1.5 minutes
LCD: LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 10.8 x 5.41 x 2.54 cm (4.25 x 2.13 x 1 in.)
Weight: 107.5 g (3.79 oz)
Environmental rating: IP50

4 Channel Analog Data Logger

4 Channel Analog Data Logger

For more informationcontact us.

Choose user manual language:

 

Choose quick start language:

Related Products

The LI-200R Pyranometer is meant to be used outdoors under unobstructed natural daylight conditions. It measures global solar radiation—the combination of direct and diffuse solar radiation—in the 400
The LI-200R Pyranometer is meant to be used outdoors under unobstructed natural daylight conditions. It measures global solar radiation—the combination of direct and diffuse solar radiation—in the 400
Monitors room occupancy and indoor light changes to identify occupancy patterns and determine energy usage and potential savings.
Monitors room occupancy and indoor light changes to identify occupancy patterns and determine energy usage and potential savings.
The LI-1500 allows for simple configuration of automated sampling to compute daily light integral (DLI) from PAR readings captured by LI-COR quantum sensors.
The LI-1500 allows for simple configuration of automated sampling to compute daily light integral (DLI) from PAR readings captured by LI-COR quantum sensors.
The LI-3000C is a lightweight, non-destructive instrument to get leaf area measurements where you need to. Ideal for rapid field surveys of attached leaves.
The LI-3000C is a lightweight, non-destructive instrument to get leaf area measurements where you need to. Ideal for rapid field surveys of attached leaves.
Low-cost, fully integrated soil moisture loggers with Bluetooth wireless data offload.
Low-cost, fully integrated soil moisture loggers with Bluetooth wireless data offload.
The LI-7820 N2O/H2O Trace Gas Analyzer offers high-precision nitrous oxide measurements in a low power, portable design—enabling it to easily integrate into survey and long-term soil flux systems.
The LI-7820 N2O/H2O Trace Gas Analyzer offers high-precision nitrous oxide measurements in a low power, portable design—enabling it to easily integrate into survey and long-term soil flux systems.
A high-accuracy, cost-effective data logger that measures and records conductivity and temperature in streams, lakes, and other freshwater sources.
A high-accuracy, cost-effective data logger that measures and records conductivity and temperature in streams, lakes, and other freshwater sources.
A miniature, waterproof, value-priced, two-channel temperature and relative light level data logger.
A miniature, waterproof, value-priced, two-channel temperature and relative light level data logger.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

4-Channel Analog Data Logger
Data Logger
4-Channel Analog Data Logger
Data Logger