Data Logger

Plug Load Data Logger

A high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads by simply plugging office equipment, vending machines, and other devices into the logger

HOBO Plug Load Data Logger

Overview

These devices can simply be plugged into the logger, and it will record all the key power parameters. This UL-certified logger provides 0.5% measurement accuracy with a measurement resolution of 1 watt, making it an ideal choice for building audits where detailed energy use data is required. The rugged housing is designed to withstand the rigors of real-world handling, providing reliable performance despite bumps, drops, and use under desks.

HOBO Plug Load Data Logger

Features
No Electrician Required

Simply plug in the device that needs to be monitored.

  • 0.5% measurement accuracy enables more reliable plug load energy data
  • “Meter Mode” provides instant viewing of real-time plug load variables
  • Provides time-stamped and totalized load data for detailed energy analysis
  • Large memory enables faster logging intervals for more comprehensive plug load profiles
  • Battery backup ensures logged data remains intact in the event of a power outage or load failure
  • Full-featured LCD display provides visual diagnostics for easy deployment
  • Compatible with HOBOware and HOBOware Pro software for logger setup and graphing & analysis

HOBO Plug Load Data Logger

Specifications

Note: The UX120-018 logger is intended for use on 15 AMP circuits (NEMA 5-15P) with a working voltage of 120V AC ±10% at 50/60Hz and a max power of 1800W.

  • Indoor use only
  • Insulation category 2

HOBO Plug Load Data Logger

Maximum Current: 15 Amps
RMS Voltage Accuracy:0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle
RMS Current Accuracy:0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle
Active Power Accuracy:0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle
Active Energy Accuracy:0.5% up to 14 Amp continuous; up to 1.0% over 14 Amp when equipment being monitored is at 100% duty cycle
Power Factor Accuracy:±0.02
Drift:Up to 0.5% typical within 1 year
Resolution:Volts, rms10mVAmps, rms0.1mAActive Power10mW down to 1 watt loads @ 120VACActive Energy10mWApparent Power10mVAPower Factor0.01 PF
Operating Environment:Logging: 5° to 40°C (41° to 104°F); 0 to 95% RH (non-condensing), up to 2,000 m (6,562 ft) altitude
Operating Modes:Meter or logging when launched with HOBOware
Logging Rate:1 second to 18 hours, 12 minutes, 15 seconds
Statistics Sampling Rate:60 Hz or 16.67 mS single-cycle
Memory Modes:Wrap when full or stop when full
Start Modes:Immediate, push button, date & time, or next interval
Stop Modes:When memory full, push button, or date & time
Restart Mode:Push button
Time Accuracy:±1 minute per month at 25°C (77°F), see Plot A
Power Source:Line-powered with 0.92 m (3 ft) AC power cord or two AAA 1.5 V alkaline batteries, user replaceable
Battery Life:2 years with line power; 6 months battery only (no line power) with logging rate of 1 minute or greater operating at 25°C (77°F)
Memory:4 MB (1.4 million measurements, maximum)
Download Type:USB 2.0 interface
Full Memory Download Time:Approximately 1.5 minutes
LCD:LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size:13.97 x 7.62 x 4.75 cm (5.5 x 3 x 1.87 in.)
Weight:230.8 g (8.14 oz)
Ratings:IP50; 
UL LogoUL Listed; UL Listed to Canadian safety standards
Calibration:This device has been calibrated using equipment that has been tested in accordance with ANSI C12.20 0.5%.
  Time Accuracy

HOBO Plug Load Data Logger

Load Data Logger

For more informationcontact us.

Choose quick start language:

 English 

Choose manual language:

Features

Choose quick start language:

 English 

Choose manual language:

Related Products

Enabled with cellular communication, this award-winning remote water level monitoring station completes calculations onsite and sends notifications of critical conditions via cellular plans to LI-COR
Some CO2 sensors are too simple. Other CO2 analyzers are costly and complex.
This 15-channel data logger lets energy and facility managers monitor energy and industrial equipment to quickly and easily detect and address a variety of issues relating to HVAC, machinery
Measures and records CO2 in buildings and other non-condensing environments.
Measures and transmits temperature and relative humidity data wirelessly to mobile devices or Windows computers via Bluetooth technology.
A miniature, value-priced, waterproof data logger for temperature monitoring applications.
LI-830 and LI-850 are just right – bringing proven performance at an economical price to provide CO2 gas measurements that you can depend on day after day.
Monitors room occupancy and indoor light changes to identify occupancy patterns and determine energy usage and potential savings.
The LI-210R Photometric Sensor measures light with the same sensitivity as a typical human eye. The photometric sensor is ideal for evaluating illumination in work areas, exhibits, interior, etc.
Ideal for energy audits, building commissioning studies, equipment scheduling, and more, this self-contained, Bluetooth-enabled, wireless data logger lets you use your mobile device or Windows

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

Plug Load Data Logger
Data Logger
Plug Load Data Logger
Data Logger