Data Logger

Type J, K, T, E, R, S, B, N Thermocouple Data Logger

A single-channel thermocouple data logger to measure and record temperature in indoor environments. Thermocouple sensors sold separately.

Thermocouple Data Logger

Overview

Designed for a broad range of monitoring applications – from industrial process monitoring to concrete maturity testing – this logger provides exceptional flexibility by accepting J, K, T, E, R, S, B or N type thermocouple probes (sold separately).

Onset also offers a four-channel thermocouple data logger, the HOBO UX120-014M.

Thermocouple Data Logger

Features
  • High-accuracy J, K, T, E, R, S, B, N thermocouple readings
  • Easy-to-view LCD display
  • Large memory capacity
  • Visual high & low alarm thresholds
  • Burst and Statistics logging modes
  • Record ambient temperature with internal thermistor
Specifications

Thermocouple


TypeRangeAccuracyResolution
J-210° to 760°C (-346° to 1,400°F)±0.6°C (±1.08°F) ± thermocouple probe accuracy0.03°C (0.06°F)
K-260° to 1,370°C (-436° to 2,498°F)±0.7°C (±1.26°F) ± thermocouple probe accuracy0.04°C (0.07°F)
T-260° to 400°C (-436° to 752°F)±0.6°C (±1.08°F) ± thermocouple probe accuracy0.02°C (0.03°F)
E-260° to 950°C (-436° to 1,742°F)±0.6°C (±1.08°F) ± thermocouple probe accuracy0.03°C at (0.05°F)
R-50° to 1,550°C (-58° to 2,822°F)±2.2°C (±3.96°F) ± thermocouple probe accuracy0.08°C (0.15°F)
S-50° to 1,720°C (-58° to 3,128°F)±2.2°C (±3.96°F) ± thermocouple probe accuracy0.08°C (0.15°F)
B550° to 1,820°C (1,022° to 3,308°F)±2.5°C (±4.5°F) ± thermocouple probe accuracy0.1°C (0.18F)
N-260° to 1,300°C (-436° to 2,372°F)±1.0°C (±1.8°F) ± thermocouple probe accuracy0.06°C (0.11°F)

Thermocouple Data Logger

Internal 10K Thermistor (Temperature)


Plot A Time Accuracy

Range: Logging: -20° to 70°C (-4° to 158°F)
Accuracy: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), see Plot A
Resolution: 0.024°C at 25°C (0.04°F at 77°F); see Plot A
Drift: <0.1°C (0.18°F) per year

Logger


Logger Operating Range
Logging: -20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing); logger accuracy from 0° to 50°C (32° to 122°F)
Launch/readout: 0° to 50°C (32° to 122°F) per USB specification

Resolution: 22-bit
Logging rate: 1 second to 18 hours, 12 minutes, 15 seconds
Logging modes: Normal, Burst or Statistics
Memory modes: Wrap when Full or Stop when Full
Start modes: Immediately, Push Button, Date & Time or Next Interval
Stop modes: When Memory Full, Push Button, or Date & Time
Restart mode: Push Button

Time Accuracy - UX120-014M

Time accuracy: ±1 minute per month at 25°C (77°F), see Plot B
Battery life: 1 year, typical with logging rate of 1 minute and sampling interval of 15 seconds or greater
Battery type: One 3V CR2032 lithium battery
Memory: 512 KB (208,076 measurements, maximum)
Download type: USB 2.0 interface
Full memory download time: 1 minute, 30 seconds
LCD: LCD is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size: 3.66 x 5.94 x 1.52 cm (1.44 x 2.34 x 0.6 in.)
Weight: 30 g (1.06 oz)
Environmental rating: IP50

Thermocouple Data Logger

For more informationcontact us.

Choose manual anguage:

 English 

Choose quick start language:

Features

Choose manual anguage:

 English 

Choose quick start language:

Related Products

The LI-190R Quantum Sensor measures photosynthetically active radiation (PAR). The LI-190R is designed for use in horticulture, ecology, greenhouses, and more.
Measures and records CO2 in buildings and other non-condensing environments.
Records motor on/off conditions within an AC magnetic field with its internal sensor, or mechanical dry contact closures from external sensing devices.
The most flexible remote data logging station from HOBO Data Loggers, the HOBO RX3000 provides instant access to site-specific environmental data anywhere, at any time, via the internet.
The industry’s first water level data logger designed for convenient wireless setup and download via Bluetooth technology.
The LI-7200RS Enclosed CO2/H2O Gas Analyzer is designed for high-speed CO2 and water vapor gas exchange measurements.
A weatherproof data logger with external temperature and relative humidity sensors.
The LI-COR LI-7815 CO2/H2O Trace Gas Analyzer provides exceptionally stable and precise measurements for long-term atmospheric monitoring measurements.
Measures rainfall to determine rainfall rates, times, and duration; for deployment with most standard tipping-bucket rain gauges.
The 6800-18 Aquatic Chamber is used to measure steady-state carbon assimilation and chlorophyll a fluorescence from algal suspensions, coral, macro algae, and sea grasses.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

Type J, K, T, E, R, S, B, N Thermocouple Data Logger
Data Logger
Type J, K, T, E, R, S, B, N Thermocouple Data Logger
Data Logger