ASTM D445, ASTM D7483

The ViscoLab 4000 is a small sample viscometer which supports up to 12 different 20:1 viscosity ranges; up to 10,000 cP with several output options. The ViscoLab 4000 can display viscosity in either centipoise or centistokes, and temperature can be displayed in either C or F. This unit requires less than 2 ml of sample and produces an extremely reliable viscosity measurement.

Due to its innovative oscillating piston design, this small sample viscometer measures fluids at ambient temperatures. An optional jacket is available for temperature control with a re-circulating bath, enabling accurate viscosity measurements from -40°C to 110°C. In addition to the sensor, sophisticated electronics provides users with substantial flexibility, including specifying temperature and viscosity display units and data averaging intervals. Correlates with ASTM D445 and complies with ASTM D7483

Easy to use, easy to clean, easy to maintain, the ViscoLab 4000 is a highly accurate, reliable and repeatable small sample viscometer.

ASTM D445, ASTM D7483

The ViscoLab 4000 is a small sample viscometer which supports up to 12 different 20:1 viscosity ranges; up to 10,000 cP with several output options. The ViscoLab 4000 can display viscosity in either centipoise or centistokes, and temperature can be displayed in either C or F. This unit requires less than 2 ml of sample and produces an extremely reliable viscosity measurement.

Due to its innovative oscillating piston design, this small sample viscometer measures fluids at ambient temperatures. An optional jacket is available for temperature control with a re-circulating bath, enabling accurate viscosity measurements from -40°C to 110°C. In addition to the sensor, sophisticated electronics provides users with substantial flexibility, including specifying temperature and viscosity display units and data averaging intervals. Correlates with ASTM D445 and complies with ASTM D7483

Easy to use, easy to clean, easy to maintain, the ViscoLab 4000 is a highly accurate, reliable and repeatable small sample viscometer.

Proprietary and Proven Technology

  • Accurate and reliable
  • Requires less than 2ml of fluid
  • Data averaging
  • Digital displays of centipoise and centistokes
  • Digital temperature display in C or F
  • RS232 Interface
  • Stores up to 40 product specific test set-ups

Easy to Use

  • Easily installed and serviced
  • One moving part, the piston
  • Self-cleaning
  • Minimum bench space required

Specifications:

Viscosity

0.2 to 10,000 centipoise (cP)

Piston Ranges (12 ranges)

0.2-2cP, 0.25-5cP, 0.5-10cP, 1-20cP,
2.5-50cP, 5-100cP, 10-200cP, 25-500cP,
50-1,000cP, 100-2,000cP, 250-5,000cP,
500-10,000cP

Accuracy

± 1.0% of full scale

Repeatability

± 0.8% of reading

Temperature sensor

4 wire internal platinum RTD

Wetted Materials

316L and 430 stainless steel

Maximum particle size

25-360 microns (range dependent)

Power

100-240 VAC/50-60Hz

For more information, contact us.

Related Products

The Cetane Ignition Delay CID 510 is a compact and easy to use analyzer, with fully automatic analysis and calibration sequences, offering analysis with extremely high precision.
The Cetane Ignition Delay CID 510 is a compact and easy to use analyzer, with fully automatic analysis and calibration sequences, offering analysis with extremely high precision.
The Optiflash accurately detects flashpoint from -30°C up to 300°C for petroleum products, biodiesels, solvents, chemicals, paint varnishes, fluxed bitumen and food and beverages.
The Optiflash accurately detects flashpoint from -30°C up to 300°C for petroleum products, biodiesels, solvents, chemicals, paint varnishes, fluxed bitumen and food and beverages.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.
Integrated diesel fuel analyzer for cloud point, pour point, viscosity, and density testing of petroleum diesel, renewable diesel, and biodiesel.
Integrated diesel fuel analyzer for cloud point, pour point, viscosity, and density testing of petroleum diesel, renewable diesel, and biodiesel.
The RB36 5G: Ring & Ball is designed for measuring product temperatures from 0°C to 220°C. The instrument enables simultaneous testing of two samples with independent monitoring.
The RB36 5G: Ring & Ball is designed for measuring product temperatures from 0°C to 220°C. The instrument enables simultaneous testing of two samples with independent monitoring.
Safe, easy to use ISL’s NCK2 5G Noack evaporation loss analyzer enables the most precise testing possible to meet increasing QS/QA requirements in full compliance with CEC, ASTM & IP methods.
Safe, easy to use ISL’s NCK2 5G Noack evaporation loss analyzer enables the most precise testing possible to meet increasing QS/QA requirements in full compliance with CEC, ASTM & IP methods.
The AC Analytical Controls® standard solutions cover a wide spectrum of petroleum, petrochemical, and natural gas analysis needs.
The AC Analytical Controls® standard solutions cover a wide spectrum of petroleum, petrochemical, and natural gas analysis needs.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

ViscoLab 4000
ViscoLab 4000