Enclosed CO2/H2O Analyzer

LI-7200RS

The next generation of the CO2/H2gas analyzer chosen by leading flux networks around the world, including NEON and ICOS.

The next generation of the CO2/H2gas analyzer chosen by leading flux networks around the world, including NEON and ICOS.

The LI-7200RS Enclosed CO2/H2O Gas Analyzer is designed for high-speed CO2 and water vapor gas exchange measurements. It combines the performance of a closed path analyzer with the ruggedness and low power demands of an open path instrument.

Minimizes data gaps with continuous measurements through rain, snow, and fog.

Improved optics and temperature controls increase long-term stability and reduce drift—even when the instrument is not cleaned for weeks at a time.

Logs complete eddy covariance data sets—including wind speed measurements from a sonic anemometer and supporting meteorological, radiation, and soil data from a LI-COR Biomet System.

Now includes the SmartFlux® System

The SmartFlux® System runs EddyPro® Software on a powerful microcomputer to compute final flux results as data are logged—the same dependable results you get from EddyPro Software on a desktop computer, only computed in real time at the site.

SmartFlux is ready to connect with FluxSuite® Software — to put your eddy covariance system online. In FluxSuite, you can view results, get email notifications, and check the performance of your instruments from a computer and smartphone.

The LI-7200RS instrument

Specifically designed for long-term eddy covariance measurements, the LI-7200RS combines the ruggedness of a field–ready instrument with the precision needed for flux measurements.

1. Patented system of high-speed temperature and pressure measurements of the sampled air provide true mole fraction for the most accurate flux measurements.

    2. Temperature-controlled source and detector for stable measurements—even in wide temperature fluctuations.

    3. Precision optical components reduce sensitivity to contamination in dusty environments.

    4. Scratch-resistant sapphire lenses for simple cleaning in the field.

    5. High-performance brushless chopper motor provides dependable long-term operation.

    Learn More

    How it works

    The LI-7200RS uses non-dispersive infrared spectroscopy to measure CO2 and water vapor densities in air. It transmits infrared radiation through temperature-controlled optical filters, then through the closed sample path to a thermally regulated lead selenide detector. Some of the infrared radiation is absorbed by CO2 and water vapor in the sample path. Gas densities are computed from the ratio of absorbed radiation to a reference.

    Using a patented configuration, the analyzer also measures temperature and pressure of the sampled air at high speeds—synchronously with the gas measurements. These data are combined to compute wet and dry mole fractions at speeds up to 20 measurements per second.

    Components

    The following accessories are available for the LI-7200RS.

    LI-7550 Analyzer Interface Unit

    Included with each LI-7200RS, it houses the gas analyzer electronics, a 16 GB USB drive for data logging, and the SmartFlux System. The LI-7550 has connections for a 3-dimensional sonic anemometer and provides Ethernet communication, making it easy to connect the LI-7200RS with FluxSuite Software.

    Inlet Cap

    Features an aerodynamic design that minimizes interference with wind flow to maximize frequency response, by minimizing flow distortion and dead volumes. A standard component of the LI-7200RS, the inlet cap is compatible with both the insulated intake tube and optional heated intake tube.

    Particle Filter

    Two 2-micron Swagelok® particle filters are included with each LI-7200RS. Compatible with both the insulated and heated intake tubes, the filter reduces the need to clean the intake tube and gas analyzer cell, improving the stability of measurements in dusty environments.

    Flow Module

    Efficient and durable, the Flow Module provides a precisely controlled airflow rate through the LI-7200RS optical path. With precise flow measurements and controls, it actively regulates the flow to ensure stable and consistent airflow rate.

    It reports flow rate, pressure drops, and diagnostic data to indicate when filters need to be cleaned or replaced.

    Insulated Intake Tube

    Included with each LI-7200RS, the insulated intake tube is ideal for measurements in dry environments with low to moderate humidity.

    • Compatible with the 2-micron particle filter.
    • Minimizes attenuation of CO2 and water vapor, while attenuating temperature by 90% to 99%.

    Heated Intake Tube

    The optional heated intake tube is recommended for humid environments. It improves frequency response of water vapor measurements by preventing water vapor sorption to the intake tube walls.

    • User settable control from 0 to 6 watts.
    • Compatible with the 2-micron particle filter.

    From the arctic tundra to the arid deserts, the LI-7200RS is designed for the most demanding environments.

    Stability and drift resistance

    The accumulation of dust, pollen, chemical residues, and other contaminants on the optics of an unfiltered enclosed gas analyzer can lead to measurement drift and cause gaps in datasets. This is not a significant problem if an instrument is filtered and regularly maintained. If an instrument is unfiltered or not maintained, however, there is risk that contaminants will affect measurements.

    Innovations in optics and electronics ensure that the LI-7200RS collects more accurate and dependable data—even as contaminants begin to accumulate on the optics.

    Data from 13 instruments at 5 sites—with exposure to different levels of contamination—consistently show that the LI-7200RS provides more stable water vapor measurements than the original LI-7200 (Figure 1). CO2 measurements (not shown) are similar to or slightly better than those of the LI-7200.

    Day of ExperimentDrift (Water Vapor, mmol per mol)Click and drag to zoom in. Hold down shift key to pan.Original LI-7200New LI-7200RS05101520253035404501234Figure 1. Water vapor measurements from two unfiltered LI-7200RS instruments and two unfiltered LI-7200 analyzers (average and spread). The y-axis shows deviation from a control reference. Measurements from the LI-7200RS analyzers drifted several times less and have smaller instrument-to-instrument variability than those from the original LI-7200. 

    Although the absence of fast air temperature and pressure measurements may appear negligible on half-hourly fluxes, the problems become apparent when computing carbon budgets (Figure 3), which can accrue large differences.

    Specifications

    CO2 Measurements

    • Calibration Range: 0 to 3000 µmol mol-1
    • Accuracy: Within 1% of reading
    • Zero Drift (per °C):
      • ±0.1 ppm typical
      • ±0.3 ppm maximum
    • RMS Noise (typical @ 370 ppm CO2 and 10 mmol mol-1 H2O):
      • @5 Hz: 0.08 ppm
      • @10 Hz: 0.11 ppm
      • @20 Hz: 0.16 ppm
    • Gain Drift (% of reading per °C @ 370 ppm):
      • ±0.02% typical
      • ±0.1% maximum
    • Direct Sensitivity to H2O (mol CO2/mol H2O):
      • ±2.00E-05 typical
      • ±4.00E-05 maximum

    H2O Measurements

    • Calibration Range: 0 to 60 mmol mol-1
    • Accuracy: Within 2% of reading
    • Zero Drift (per °C):
      • ±0.03 mmol mol-1 typical
      • ±0.05 mmol mol-1 maximum
    • RMS Noise (typical @ 370 ppm CO2 and 10 mmol mol-1 H2O):
      • @5 Hz: 0.0034 mmol mol-1
      • @10 Hz: 0.0047 mmol mol-1
      • @20 Hz: 0.0067 mmol mol-1
    • Gain Drift(% of reading per °C @ 20 mmol mol-1):
      • ±0.15% typical
      • ±0.30% maximum
    • Direct Sensitivity to CO2 (mol H2O/mol CO2):
      • ±0.02 typical
      • ±0.05 maximum

    General

    • Analysis Type: Absolute, non-dispersive infrared spectroscopy
    • Data Storage: 16 GB removable industrial grade USB storage device
    • Data Communication: Ethernet, Synchronous Devices for Measurement (SDM; >50 Hz), RS-232 (115,200 baud; 20 records per second max), 6 DACs (0-5 V; 300 Hz)
    • Inputs: Four analog input channels (differential; bi-polar; ±5 V; 300 Hz)
    • Operating Temperature Range: -25 to 50 °C (-40 to 50 °C verification test available on request)
    • Power Requirements: 10.5 to 30 volts DC
    • Power Consumption: 12 W nominal (up to 30 W during startup)
    • Detector: Thermoelectrically cooled lead selenide
    • Bandwidth: 5, 10, or 20 Hz, user-selectable
    • User Interface: Windows® based
    • Cable length: 5 meters (all cables); 5-meter head cable extension available

    Analyzer Head

    • Size: 7.5 cm (36” diameter), 31 cm (12.2”) length
    • Weight: 1.8 kg (3.95 lbs.)

    LI-7550 Analyzer Interface Unit

    • Size: 35 cm × 30 cm × 15 cm (13.8” × 12” × 6”)
    • Weight: 4.4 kg (10 lbs)

    7200-101 Flow Module

    • Operating Temperature Range: -25 to 50 °C
    • Power Requirements: 10.5 to 30 VDC
    • Power Consumption: < 16 W nominal
    • Flow Rate: 15 LPM nominal
    • Size: 35 cm × 30 cm × 15 cm (13.8” × 12” × 6”)
    • Weight: 6.15 kg (13.55 lbs)

    Insulated Intake Tube

    • Length: Up to 1 meter
    • Inside Diameter: 5.33 mm
    • Outside Diameter: 6.35 mm

    Heated Intake Tube

    • Length: 71.1 cm
    • Inside Diameter: 5.33 mm
    • Outside Diameter: 6.35 mm
    • Operating Temperature Range: -40 to 50 °C
    • Output Wattage: 0.1 to 6 W
    • Heat Density Ratio (short tube to long tube): 2:1
    • Weight: 0.54 kg (1.2 lbs)

    7550-101 Auxiliary Sensor Interface

    • Size: 11.5 cm × 6.5 cm × 4.2 cm (4.5” × 2.6” × 1.7”)
    • Weight: 0.39 kg (0.85 lbs) including mounting bracket

    Specifications subject to change without notice.

    Tags: atmospheric research, environmental monitoring, eddy covariance, atmospheric science, environmental science equipment philippines

    For more information, contact us.

    Publications and Posters

    See publications that use LI-COR eddy covariance analyzers.

    Get the Publications List

    Posters

    Using Flux Measurements for Immediate Societal Benefits
    Burba, G., 2022. Using Flux Measurements for Immediate Societal Benefits. American Geophysical Union Fall Meeting, Chicago, Illinois, 12-16 December.

    2155 Past & Present Eddy Covariance Measurement Locations, & Still Counting
    Burba G., 2019. Illustrative Maps of Past and Present Eddy Covariance Measurement Locations: II. High-Resolution Images. Retrieved August 6, 2019, www.researchgate.net 9 pp. DOI: 10.13140/RG.2.2.33191.70561

    Tovi, New Software for Flux Data Analysis: from Gap Filling to Flux & Footprint Partitioning
    G. Burba, I. Begashaw, A. Forgione, N. Franken, F. Griessbaum, P. Isaac, D. Johnson, J. Kathilankal, A. McQuistan, A. Parkinson, M. Sun, A. Templeton, L. Woodford, and G. Fratini, 2019. Tovi, New Software for Flux Data Analysis: from Gap Filling to Flux & Footprint Partitioning. European Geosciences Union General Assembly, Vienna, Austria, 07-12 April.

    Eddy Covariance flux errors due to synchronization issues during data acquisition
    Gerardo Fratini, Simone Sabbatini, Kevin Ediger, Brad Riensche, George Burba, Giacomo Nicolini, Domenico Vitale, and Dario Papale, 2019. Eddy Covariance flux errors due to synchronization issues during data acquisition. European Geosciences Union General Assembly, Vienna, Austria, 07-12 April.

    Investigation on the Importance of Fast Air Temperature Measurements in the Sampling Cell of Short-Tube Closed-Path Gas Analyzer for Eddy Covariance Fluxes
    James Kathilankal, Gerardo Fratini, George Burba, 2014. American Geophysical Union Fall Meeting, San Francisco, California, 15-19 December.

    A New Tool for Automated Data Collection and Complete On-Site Flux Data Processing for Eddy Covariance Measurements
    Israel Begashaw, James Kathilankal, Jiahong Li, Kevin Beaty, Kevin Ediger, Antonio Forgione, Gerardo Fratini, David Johnson, Michael Velgersdyk, Liukang Xu, George Burba, 2014. American Geophysical Union Fall Meeting, San Francisco, California, 15-19 December.

    Direct Continuous Measurements of Methane Emissions From a Landfill
    George Burba, Liukang Xu, Xiaomao Lin, Jim Amen, Karla Welding, Dayle McDermitt, 2014. American Geophysical Union Fall Meeting, San Francisco, California, 15-19 December.

    Expanding Spatial and Temporal Coverage of Arctic CH4 and CO2 Fluxes
    Patrick Murphy, Walter Oechel, Virginie Moreaux, Salvatore Losacco, and Donatella Zona, 2013. American Geophysical Union Fall Meeting, San Francisco, California, 9-12 December.

    Efficacy of Using Eddy Covariance Method for Gas and Energy Flux measurements in Disciplines and Applications beyond Micrometeorology.
    Burba, G., and D. Anderson, 2011. Efficacy of Using Eddy Covariance Method for Gas and Energy Flux measurements in Disciplines and Applications beyond Micrometeorology. European Geosciences Union General Assembly, Vienna, Austria, 03-06 April. Submitted

    Combining the strengths of open-path and closed-path designs into a single CO2/H2gas analyzer
    Burba, G., M. Furtaw, D. McDermitt, and R. Eckles, 2009. Combining the strengths of open-path and closed-path designs into a single CO2/H2gas analyzer. American Geophysical Union Fall Meeting, San Francisco, California, 14-18 December.

    Solution for Minimizing Surface Heating Effect for Fast Open-path CO2 Flux Measurements in Cold Environments
    Burba, G., D. McDermitt, J. Hupp, D. Anderson, and R. Eckles, 2010. Solution for Minimizing Surface Heating Effect for Fast Open-path CO2 Flux Measurements in Cold Environments. American Geophysical Union Fall Meeting, San Francisco, California, 13-17 December.

    Calculating CO2 and H2Eddy Covariance Fluxes from Low-power Gas Analyzer Using Fast Mixing Ratio
    Burba, G., A. Schmidt, R. Scott, J. Kathilankal, B. Law, D. McDermitt, D. Anderson, R. Eckles, M. Furtaw, and M. Velgersdyk, 2010. Calculating CO2 and H2Eddy Covariance Fluxes from Low-power Gas Analyzer Using Fast Mixing Ratio. American Geophysical Union Fall Meeting, San Francisco, California, 13-17 December.

    Eddy Covariance Measurements of Methane Flux at Remote Sites with New Low-Power Lightweight Fast Gas Analyzer
    Burba, G., L. Xu, J. Schedlbauer, D. Zona, T. Anderson, D.K. McDermitt, S. Oberbauer, W. Oechel, A. Komissarov, and B. Riensche, 2010. . European Geosciences Union General Assembly, Vienna, Austria, 02-07 May.

    Brochures

    Eddy Covariance Solutions

    Sistemas Eddy Covariance

    LI-7200RS Enclosed CO2/H2O Gas Analyzer

    LI-7700 Open Path CH4 Analyzer

    LI-7200RS Enclosed CO2/H2O Gas Analyzer

    LI-7500DS Open Path CO2/H2O Gas Analyzer

    LI-7700 Open Path CH4 Gas Analyzer

    Systems Integration

    Tripod and Mounting Hardware

    FluxSuite® Software

    Biomet Systems and Sensors

    Global Communications

    EddyPro® Software

    Solar Power

    Sonic Anemometers

    Field guide to instruments for the earth sciences

    Related Products

    LI-COR eddy covariance systems measure the exchange of CO2, H2O, CH4 , and energy between the earth’s surface and the atmosphere, empowering researchers to advance scientific understanding of climate
    LI-COR eddy covariance systems measure the exchange of CO2, H2O, CH4 , and energy between the earth’s surface and the atmosphere, empowering researchers to advance scientific understanding of climate
    Handheld water quality meters that measure pH, conductivity, resistivity, salinity, TDS and DO. Waterproof, dust proof, eco-friendly, shock and scratch resistant and built for hands-free testing.
    Handheld water quality meters that measure pH, conductivity, resistivity, salinity, TDS and DO. Waterproof, dust proof, eco-friendly, shock and scratch resistant and built for hands-free testing.
    With an integrated sensor, measures and records temperature in indoor environments.
    With an integrated sensor, measures and records temperature in indoor environments.
    The 8200-104 Opaque Long-Term Chamber accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.
    The 8200-104 Opaque Long-Term Chamber accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.
    The LI-193 Spherical Quantum Sensor measures PAR in air or underwater from all directions at depths up to 350 meters. This sensor is useful for studies of phytoplankton, which uses radiation from …
    The LI-193 Spherical Quantum Sensor measures PAR in air or underwater from all directions at depths up to 350 meters. This sensor is useful for studies of phytoplankton, which uses radiation from …
    LI-830 and LI-850 are just right – bringing proven performance at an economical price to provide CO2 gas measurements that you can depend on day after day.
    LI-830 and LI-850 are just right – bringing proven performance at an economical price to provide CO2 gas measurements that you can depend on day after day.
    The LI-7200RS Enclosed CO2/H2O Gas Analyzer is designed for high-speed CO2 and water vapor gas exchange measurements.
    The LI-7200RS Enclosed CO2/H2O Gas Analyzer is designed for high-speed CO2 and water vapor gas exchange measurements.
    The LI-7500DS is designed for high-speed CO2 and water vapor measurements in ambient air. Lower power and maintenance requirements make it ideal for field deployments.
    The LI-7500DS is designed for high-speed CO2 and water vapor measurements in ambient air. Lower power and maintenance requirements make it ideal for field deployments.

    Product added to Quote list ✔

    failure analysis, material characterization, and metrology equipment

    Subscribe to newsletter

    Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

    Inquire for this Product

    LI-7200RS
    Enclosed CO2/H2O Analyzer
    LI-7200RS
    Enclosed CO2/H2O Analyzer