Line Quantum Sensor

LI-191R

The LI-191R Line Quantum Sensor measures PAR integrated over its 1-meter length. It is used to measure sunlight under a plant canopy, where the light field is non-uniform. The LI-191R makes it easy to measure under-canopy light in many plots quickly and consistently. It measures light in units of Photosynthetic Photon Flux Density (PPFD), which is expressed as μmol s-1 m-2.

Why choose the LI-191R

  • Improved water resistance for long-term outdoor deployment
  • Integrated measurements using a single detector prevents variance found in sensors that use multiple detectors
  • Selected by the National Ecological Observatory Network (NEON®) for integrated PAR measurements
LI-191R Quantum Line Sensor

How does it work?

The LI-191R uses a 1-meter long quartz rod under a diffuser to direct light to a single filtered silicon photodiode. The entire LI-191R diffuser is sensitive to light over its 1-meter length. Since the diffuser is one continuous piece, the LI-191R essentially integrates an infinite number of points over its surface into a single value that represents light from the entire 1-meter length. Optical filters block radiation with wavelengths beyond 700 nm, which is critical for under-canopy measurements, where the ratio of infrared to visible light may be high. The unique design of the LI-191R provides an excellent quantum response that is close to the ideal quantum response.

LI-191R Specifications

  • Absolute Calibration: ± 10% traceable to National Institute of Science and Technology (NIST). The LI-191 is calibrated via transfer calibration using a reference LI-190R Quantum Sensor. Transfer error is ± 5% (included in the ± 10%)
  • Sensitivity: Typically 7 μA per 1,000 μmol s-1 m-2
  • Linearity: Maximum deviation of 1% up to 10,000 μmol s-1 m-2
  • Response Time: 10 μs
  • Temperature Dependence: ± 0.15% per °C maximum
  • Cosine Correction: Acrylic diffuser
  • Azimuth: < ± 2% error over 360° at 45° elevation
  • Operating Temperature Range: −40 °C to 65 °C
  • Relative Humidity Range: 0% to 95% RH, Non-Condensing 
  • Sensitivity Variation over Length: ± 7% maximum using a 2.54 cm (1”) wide beam from an incandescent light source.
  • Sensing Area: 1 m × 12.7 mm (39.4” × 0.50”)
  • Detector: High stability silicon photovoltaic detector (blue enhanced)
  • Sensor Housing: Weatherproof anodized aluminum housing with acrylic diffuser and stainless steel hardware.
  • Size: 121.3 L × 2.54 W × 2.54 cm D (47.7” × 1.0” × 1.0”)
  • Weight: 1.4 kg (3.0 lbs.)
  • Cable Length: 3.1 m (10.0 ft.)

Brochures

Light Measurement

Light Measurement Solutions for Greenhouse Management

LI-1500 Light Sensor Logger

Principles of Radiation Measurement

Field guide to instruments for the earth sciences

Features

Why choose the LI-191R

  • Improved water resistance for long-term outdoor deployment
  • Integrated measurements using a single detector prevents variance found in sensors that use multiple detectors
  • Selected by the National Ecological Observatory Network (NEON®) for integrated PAR measurements
LI-191R Quantum Line Sensor

How does it work?

The LI-191R uses a 1-meter long quartz rod under a diffuser to direct light to a single filtered silicon photodiode. The entire LI-191R diffuser is sensitive to light over its 1-meter length. Since the diffuser is one continuous piece, the LI-191R essentially integrates an infinite number of points over its surface into a single value that represents light from the entire 1-meter length. Optical filters block radiation with wavelengths beyond 700 nm, which is critical for under-canopy measurements, where the ratio of infrared to visible light may be high. The unique design of the LI-191R provides an excellent quantum response that is close to the ideal quantum response.

LI-191R Specifications

  • Absolute Calibration: ± 10% traceable to National Institute of Science and Technology (NIST). The LI-191 is calibrated via transfer calibration using a reference LI-190R Quantum Sensor. Transfer error is ± 5% (included in the ± 10%)
  • Sensitivity: Typically 7 μA per 1,000 μmol s-1 m-2
  • Linearity: Maximum deviation of 1% up to 10,000 μmol s-1 m-2
  • Response Time: 10 μs
  • Temperature Dependence: ± 0.15% per °C maximum
  • Cosine Correction: Acrylic diffuser
  • Azimuth: < ± 2% error over 360° at 45° elevation
  • Operating Temperature Range: −40 °C to 65 °C
  • Relative Humidity Range: 0% to 95% RH, Non-Condensing 
  • Sensitivity Variation over Length: ± 7% maximum using a 2.54 cm (1”) wide beam from an incandescent light source.
  • Sensing Area: 1 m × 12.7 mm (39.4” × 0.50”)
  • Detector: High stability silicon photovoltaic detector (blue enhanced)
  • Sensor Housing: Weatherproof anodized aluminum housing with acrylic diffuser and stainless steel hardware.
  • Size: 121.3 L × 2.54 W × 2.54 cm D (47.7” × 1.0” × 1.0”)
  • Weight: 1.4 kg (3.0 lbs.)
  • Cable Length: 3.1 m (10.0 ft.)

Brochures

Light Measurement

Light Measurement Solutions for Greenhouse Management

LI-1500 Light Sensor Logger

Principles of Radiation Measurement

Field guide to instruments for the earth sciences

Related Products

The LI-7500DS is designed for high-speed CO2 and water vapor measurements in ambient air. Lower power and maintenance requirements make it ideal for field deployments.
The LI-192 Underwater Quantum Sensor measures PAR from all angles in one hemisphere. The LI-192 works in air or underwater at depths up to 560 meters.
The LI-7200RS Enclosed CO2/H2O Gas Analyzer is designed for high-speed CO2 and water vapor gas exchange measurements.
The LI-180 Spectrometer lets you capture the spectral composition of your light sources with a single click.
The 8200-01S Smart Chamber is a portable, self-powered 20 cm survey chamber used to assess the spatial variability of soil gas fluxes.
The LI-COR LI-7815 CO2/H2O Trace Gas Analyzer provides exceptionally stable and precise measurements for long-term atmospheric monitoring measurements.
The LAI‑2200C Plant Canopy Analyzer uses a non-destructive method to easily and accurately measure Leaf Area Index (LAI).
The LI-190R Quantum Sensor measures photosynthetically active radiation (PAR). The LI-190R is designed for use in horticulture, ecology, greenhouses, and more.
Choose the LI-250Q package for spot measurements of photosynthetically active radiation (PAR) intensity and quantity with unrivaled accuracy.
The LI-3100C is a rugged bench-top instrument designed to quickly digitize the area, length, and width of leaves.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

LI-191R
Line Quantum Sensor
LI-191R
Line Quantum Sensor