Nitrogen Plasma Spectrometer

MICAP-OES 1000

Unique Design
Unique Performance

Optical Emission Spectrometer
Echelle spectrometer simultaneously measures the entire wavelength range with every solution injection.

Wavelength range: 194 nm – 625 nm + 766 nm

Resolution 5pm – 30 pm, 7 pm at 200 nm

Annual CO2e Emissions Savings Compared to Argon Carbon Footprint

Unique Design
Unique Performance

Optical Emission Spectrometer
Echelle spectrometer simultaneously measures the entire wavelength range with every solution injection.

Wavelength range: 194 nm – 625 nm + 766 nm

Resolution 5pm – 30 pm, 7 pm at 200 nm

Annual CO2e Emissions Savings Compared to Argon Carbon Footprint

Product Specification

Variable speed four-channel peristaltic pump and concentric 1 mL/min nebulizer are standard sample introduction assembly (SIA) components.

Vertical torch position with axial viewing and automated, uniform plasma tail removal.

Echelle Spectrometer simultaneously measures the entire wavelength range with every solution injection.

Power requirements:

  • Mains power: 208 V to 240 V/10 A
  • No water cooling required

Exhaust:

  • 4 inch (100 mm) exhaust with flow rate between 100 – 200 cfm (1.5 – 2.9 m/s)

Gas flows:

  • Mass flow controlled coolant, auxillary and nebulizer gas for reliable and stable sample measurement
  • Typical plasma gas flow is 14L/min
  • Nitrogen gas can be sourced from liquid dewar, compressed gas cylinder or nitrogen generator

Size:

  • [W] 20.7 in (525 mm) x [H] 22 in (560 mm) x [D] 14 in (350 mm)

Weight:

  • MICAP Plasma Source Unit 42 lbs (19 kg)
  • Total weight of MICAP with Spectrometer 67 lbs (30 kg)

Camera

Detector

  • sCMOS

Array diagonal:

  • 31 mm

Resolution:

  • 2048 x 2048

Cooling:

  • Peltier cooled to -10 °C

Other parameters:

  • Pixel size: 11 µm x 11 µm
  • Frame rate: 24 fps

Optical Emission Spectrometer of OES 1000 Plasma Source

Wavelength range:

  • Simultaneous measurement 194 nm – 625 nm + 766 nm

Slit Width:

  • 30 um slit

Resolution:

  • 5pm – 30 pm, 7 pm at 200 nm

Operating environment:

  • Temperature: 20 – 25 °C (68 – 77 °F)
  • Relative Humidity: 20-60 %

Key Design Features

  • Simplified architecture with Methods for conditions and Sessions for running samples
  • Detailed peak viewing with quick peak integration settings
  • Spectral database to highlight potential spectral overlaps
  • Live time scan for sample introduction optimization

Key Performance Features

  • AI-powered spectral processing
  • Continuous Nitrogen background correction
  • Simultaneous data capture allows application of internal standardization in high matrix samples
  • Full spectrum capture provides alternate line addition
  • Delivers full analysis flexibility post-acquisition

OES 1000 Plasma Source

OES 1000 Plasma Source

For more informationcontact us.

Click here.

Application Note: Lubricant Oil Analysis for Wear Metals, Additives, and Ingress Elements

Application Note – MICAP OES Lubricant Oil

Related Products

The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
SimPrep+ Automated Liquid Handling Station is robust and easy to use, with fast, accurate results.
SimPrep+ Automated Liquid Handling Station is robust and easy to use, with fast, accurate results.
In combination with very sensitive detector technology, especially the fluorescence detector, the Chromaster HPLC system is one of the strongest LC systems on the market.
In combination with very sensitive detector technology, especially the fluorescence detector, the Chromaster HPLC system is one of the strongest LC systems on the market.
Designed for high-accuracy absorbance measurements and spectral analysis of materials, chemicals, and research samples.
Designed for high-accuracy absorbance measurements and spectral analysis of materials, chemicals, and research samples.
The Teledyne LABS ASXpress® Plus Rapid Sample Injection System reduces the time required for autosampler movement, sample uptake, stabilization, and rinse operations with ICP-OES and ICP-MS. The resul
The Teledyne LABS ASXpress® Plus Rapid Sample Injection System reduces the time required for autosampler movement, sample uptake, stabilization, and rinse operations with ICP-OES and ICP-MS. The resul
Intuitive and very easy to use touch panel operation. Easy to clean glass top and round body. Horiba LAQUA Benchtop Type Water Quality Meter is both easy and fun to use!
Intuitive and very easy to use touch panel operation. Easy to clean glass top and round body. Horiba LAQUA Benchtop Type Water Quality Meter is both easy and fun to use!
Used to measure fluorescence excitation and emission spectra for qualitative and quantitative analysis of fluorescent substances.
Used to measure fluorescence excitation and emission spectra for qualitative and quantitative analysis of fluorescent substances.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

MICAP-OES 1000
Nitrogen Plasma Spectrometer
MICAP-OES 1000
Nitrogen Plasma Spectrometer