Nitrogen Plasma Spectrometer

MICAP-OES 1000

Unique Design
Unique Performance

Optical Emission Spectrometer
Echelle spectrometer simultaneously measures the entire wavelength range with every solution injection.

Wavelength range: 194 nm – 625 nm + 766 nm

Resolution 5pm – 30 pm, 7 pm at 200 nm

Annual CO2e Emissions Savings Compared to Argon Carbon Footprint

Unique Design
Unique Performance

Optical Emission Spectrometer
Echelle spectrometer simultaneously measures the entire wavelength range with every solution injection.

Wavelength range: 194 nm – 625 nm + 766 nm

Resolution 5pm – 30 pm, 7 pm at 200 nm

Annual CO2e Emissions Savings Compared to Argon Carbon Footprint

Product Specification

Variable speed four-channel peristaltic pump and concentric 1 mL/min nebulizer are standard sample introduction assembly (SIA) components.

Vertical torch position with axial viewing and automated, uniform plasma tail removal.

Echelle Spectrometer simultaneously measures the entire wavelength range with every solution injection.

Power requirements:

  • Mains power: 208 V to 240 V/10 A
  • No water cooling required

Exhaust:

  • 4 inch (100 mm) exhaust with flow rate between 100 – 200 cfm (1.5 – 2.9 m/s)

Gas flows:

  • Mass flow controlled coolant, auxillary and nebulizer gas for reliable and stable sample measurement
  • Typical plasma gas flow is 14L/min
  • Nitrogen gas can be sourced from liquid dewar, compressed gas cylinder or nitrogen generator

Size:

  • [W] 20.7 in (525 mm) x [H] 22 in (560 mm) x [D] 14 in (350 mm)

Weight:

  • MICAP Plasma Source Unit 42 lbs (19 kg)
  • Total weight of MICAP with Spectrometer 67 lbs (30 kg)

Camera

Detector

  • sCMOS

Array diagonal:

  • 31 mm

Resolution:

  • 2048 x 2048

Cooling:

  • Peltier cooled to -10 °C

Other parameters:

  • Pixel size: 11 µm x 11 µm
  • Frame rate: 24 fps

Optical Emission Spectrometer of OES 1000 Plasma Source

Wavelength range:

  • Simultaneous measurement 194 nm – 625 nm + 766 nm

Slit Width:

  • 30 um slit

Resolution:

  • 5pm – 30 pm, 7 pm at 200 nm

Operating environment:

  • Temperature: 20 – 25 °C (68 – 77 °F)
  • Relative Humidity: 20-60 %

Key Design Features

  • Simplified architecture with Methods for conditions and Sessions for running samples
  • Detailed peak viewing with quick peak integration settings
  • Spectral database to highlight potential spectral overlaps
  • Live time scan for sample introduction optimization

Key Performance Features

  • AI-powered spectral processing
  • Continuous Nitrogen background correction
  • Simultaneous data capture allows application of internal standardization in high matrix samples
  • Full spectrum capture provides alternate line addition
  • Delivers full analysis flexibility post-acquisition

OES 1000 Plasma Source

OES 1000 Plasma Source

For more information, contact us.

Click here.

Application Note: Lubricant Oil Analysis for Wear Metals, Additives, and Ingress Elements

Application Note – MICAP OES Lubricant Oil

Related Products

The Atomx XYZ is the second generation combined soil/water autosampler and purge and trap concentrator system in the Tekmar VOC product family.
The Atomx XYZ is the second generation combined soil/water autosampler and purge and trap concentrator system in the Tekmar VOC product family.
The Fusion TOC Analyzer offers more flexibility, intelligence and user friendliness making this analyzer ideally suited for the most demanding laboratory needs.
The Fusion TOC Analyzer offers more flexibility, intelligence and user friendliness making this analyzer ideally suited for the most demanding laboratory needs.
Uses simultaneous measurement with three lasers at different power levels, ensuring every particle is accurately tracked, regardless of its scattering intensity.
Uses simultaneous measurement with three lasers at different power levels, ensuring every particle is accurately tracked, regardless of its scattering intensity.
The AminoSAAYA offers easy and comfortable operability while maintaining the reliability and stability of Hitachi’ s legacy amino acid analyzers.
The AminoSAAYA offers easy and comfortable operability while maintaining the reliability and stability of Hitachi’ s legacy amino acid analyzers.
Capturing particle size distribution and shape simultaneously to reduce measurement time, streamline R&D and QC workflows, and save lab space.
Capturing particle size distribution and shape simultaneously to reduce measurement time, streamline R&D and QC workflows, and save lab space.
Your lab-in-a-pocket. Horiba LAQUAtwin’s unique pocket meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop
Your lab-in-a-pocket. Horiba LAQUAtwin’s unique pocket meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop
Reduces analysis time and costs while enhancing analysis accuracy and functionality.
Reduces analysis time and costs while enhancing analysis accuracy and functionality.
Uses a tubular electric resistance heating furnace, offers highly accurate and sensitive analysis
Uses a tubular electric resistance heating furnace, offers highly accurate and sensitive analysis

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

MICAP-OES 1000
Nitrogen Plasma Spectrometer
MICAP-OES 1000
Nitrogen Plasma Spectrometer