Opaque Long-Term Chamber

8200-104

The 8200-104 Opaque Long-Term Chamber builds on the trusted and patented technology from the previous generation. This line of long-term chambers withstands the elements with improvements to the design. The 8200-104 accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.

A motorized chamber finished in durable and reflective white enamel rotates away from your soil collar. This allows the soil in the collar to see natural environmental conditions when a measurement is not taking place. The chamber may be left unattended for extended periods of time to make automated measurements, with low power draw (7.5W maximum when opening or closing).

How are LI-COR chambers different?

The 8200-104 Opaque Long-Term Chamber and all LI-COR chambers have been carefully and intentionally designed to minimize their impact on the natural soil activity with consideration toward:

  • Maintaining chamber pressure with ambient air.
  • Achieving air mixing without a fan.
  • Accounting for the impact of altered diffusion gradient on the flux.
  • Minimizing the impact of the chamber on your soil environment.

 Learn more about the science and engineering behind the 8200-104 Opaque Long-Term Chamber.

8200-104 Chamber

Specifications

  • Dimensions: 48.3 cm L × 38.1 cm W × 33.0 cm H
  • Weight: 7.3 kg
  • Chamber Volume: 4076.1 cm3
  • Soil Area Exposed: 317.8 cm2
  • Weatherproof Rating: Tested to IEC IP55 standard
  • Air Temperature Thermistor:
    • Operating Range: -20 to 50 °C
    • Accuracy: ±0.3 °C from -20 to 50 °C
  • Light Sensor Current Input:
    • Range: 0 to 100 µA
    • Resolution: 1.5 nA
    • Accuracy: ±(0.37 % of Reading + 8 nA) from -20 to 50 °C
  • SDI-12 Communications Interface:
    • Max Number of Devices: 10
    • Output Voltage: 12 VDC, 200 mA

Specifications subject to change without notice.

Brochure

8250-02 Calibration Manifold Insert

Soil Gas Flux Measurement Solutions

Field guide to instruments for the earth sciences

Features

How are LI-COR chambers different?

The 8200-104 Opaque Long-Term Chamber and all LI-COR chambers have been carefully and intentionally designed to minimize their impact on the natural soil activity with consideration toward:

  • Maintaining chamber pressure with ambient air.
  • Achieving air mixing without a fan.
  • Accounting for the impact of altered diffusion gradient on the flux.
  • Minimizing the impact of the chamber on your soil environment.

 Learn more about the science and engineering behind the 8200-104 Opaque Long-Term Chamber.

8200-104 Chamber

Specifications

  • Dimensions: 48.3 cm L × 38.1 cm W × 33.0 cm H
  • Weight: 7.3 kg
  • Chamber Volume: 4076.1 cm3
  • Soil Area Exposed: 317.8 cm2
  • Weatherproof Rating: Tested to IEC IP55 standard
  • Air Temperature Thermistor:
    • Operating Range: -20 to 50 °C
    • Accuracy: ±0.3 °C from -20 to 50 °C
  • Light Sensor Current Input:
    • Range: 0 to 100 µA
    • Resolution: 1.5 nA
    • Accuracy: ±(0.37 % of Reading + 8 nA) from -20 to 50 °C
  • SDI-12 Communications Interface:
    • Max Number of Devices: 10
    • Output Voltage: 12 VDC, 200 mA

Specifications subject to change without notice.

Brochure

8250-02 Calibration Manifold Insert

Soil Gas Flux Measurement Solutions

Field guide to instruments for the earth sciences

Related Products

The LI-190R Quantum Sensor measures photosynthetically active radiation (PAR). The LI-190R is designed for use in horticulture, ecology, greenhouses, and more.
The LI-7820 N2O/H2O Trace Gas Analyzer offers high-precision nitrous oxide measurements in a low power, portable design—enabling it to easily integrate into survey and long-term soil flux systems.
Handheld water quality meters that measure pH, conductivity, resistivity, salinity, TDS and DO. Waterproof, dust proof, eco-friendly, shock and scratch resistant and built for hands-free testing.
The LAI‑2200C Plant Canopy Analyzer uses a non-destructive method to easily and accurately measure Leaf Area Index (LAI).
The 6800-18 Aquatic Chamber is used to measure steady-state carbon assimilation and chlorophyll a fluorescence from algal suspensions, coral, macro algae, and sea grasses.
The LI-550 reports wind speed, direction, temperature, humidity, pressure, tilt, and compass data. Its size and weight make it perfect for many UAS/UAV.
The LI-191R Line Quantum Sensor measures PAR integrated over its 1-meter length. It is used to measure sunlight under a plant canopy, where the light field is non-uniform.
Get rapid insights into stomatal conductance, chlorophyll fluorescence, and leaf angle for a variety of leaf sizes and morphologies, including many needles and narrow grasses.
The LI-180 Spectrometer lets you capture the spectral composition of your light sources with a single click.
The 8200-104C Clear Long-Term Chamber has been specially designed for NCE measurements. It includes technology and patents designed to minimize chamber impact on natural plant and soil activity with c

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

8200-104
Opaque Long-Term Chamber
8200-104
Opaque Long-Term Chamber