Trace Gas Analyzers

LI-7815

Grounded in Science, Designed for Research

From idea to understanding, LI-COR has your soil gas flux research covered. No other solution is as flexible or delivers the same level of proven hardware, gas analyzers, and advanced data analysis software.

Grounded in Science, Designed for Research

From idea to understanding, LI-COR has your soil gas flux research covered. No other solution is as flexible or delivers the same level of proven hardware, gas analyzers, and advanced data analysis software.

LI-COR LI-7815 Trace Gas Analyzer Philippines

High precision CO2 monitoring

The LI-COR LI-7815 CO2/H2O Trace Gas Analyzer provides exceptionally stable and precise measurements for long-term atmospheric monitoring measurements. CO2 measurements drift less than 0.2 ppm per 24-hour period with 0.04 ppm precision (1σ, with 5-second averaging) at 400 ppm CO2 in dry air at STP.

Exceptionally stable and precise measurements

The LI-7815 CO2/H2O Gas Analyzer provides stable and precise CO2 measurements in a rugged, portable, and cost-effective design.

LI-7815 Long-Term Outdoor CO2 Stability

LI-7815 Long-Term Outdoor CO2 Stability
Thirty-day CO2 stability data from an LI-7815 CO2/H2O analyzer. A single instrument was operated outdoors continuously over the entire time period, measuring ambient air between stability checks. During stability checks, the analyzer was flushed for 10 minutes with tank gas (2 ppm CH4, 400 ppm CO2 mixed in air balance, 1% nominal concentration accuracy) and a time series data set was subsequently recorded for 10 minutes every 12 hours. The figure shows the mean value of the 10-minute measurements. Error bars represent a 1σ confidence interval (68%).

LI-7815 24-Hour CO2 Precision with Allan Deviation Plot

LI-7815 24-Hour CO2 Precision with Allan Deviation Plot
Figure 2. 24-hour CO2 stability data from an LI-7815 CO2/H2O analyzer (top). The instrument was operated continuously over a 24-hour period with a continuous flow of tank gas. The blue line shows 1-second measurements; the diamond line shows a 50-minute block average. Allan deviation plot (bottom) of CO2 measurements from an LI-7815 measuring 402.3 ppm CO2 shows precision at 1-second signal averaging, with improved precision as averaging time increases. Error bars represent 68% (±1σ) confidence intervals based on number of averaged time series available at each τ.

Key specifications

General

  • Total Weight: 10.5 kg (including batteries)
  • Battery Life: 8 hours typical with 2 batteries

CO2 Measurements

  • Response Time (T10-T90): all from 0 to 400 ppm
    • ≤ 2 seconds in Standard Configuration
    • ≤ 3 seconds in High Altitude Configuration
  • Range: 0 to 10,000 ppm
  • Precision (1σ):
    • 0.10 ppm at 400 ppm with 1 second averaging
    • 0.04 ppm at 400 ppm with 5 second averaging
  • Maximum Drift: < 0.2 ppm per 24-hour period

See the full LI-7815 specs

Applications

The LI-7815 Trace Gas Analyzer can be used for, but is not limited to, the following applications:

  • Atmospheric monitoring
  • Urban emissions monitoring
  • Mobile emissions monitoring
  • pCO2
  • Sensor networks
  • Large area emissions monitoring
  • Fugitive emissions
LI-7815 CO2_H2O Trace Gas Analyzer Philippines

For more information, contact us.

Brochure

Trace Gas Analyzers

Trace Gas Analyzers

Field guide to instruments for the earth sciences

Field guide to instruments for the earth sciences

Posters

Trace Gas Poster iconDevelopment of Trace Carbon Dioxide Isotopologue Analyzer – Performance Evaluation Study

Long-Term TGA Measurements at Mace Head, IrelandLong-Term Atmospheric Monitoring of Background CH4 and CO2 at Mace Head Atmospheric Research Station, Ireland Using LI-COR LI-7810 and LI-7815 Trace Gas Analyzers

TGA Urban N2O Soil posterHow do soil temperature and moisture regulate N2flux from an urban lawn?

TGA OF-CEAS posterMeasuring Very Small Soil Fluxes of N2CH4 Using a New OF-CEAS Technology

Trace Gas Poster iconDevelopment of Trace Methane and Trace Carbon Dioxide Analyzers – Performance Evaluation Studies, GCWerks Integration, and Results of Field Deployment

Trace Gas Poster iconPerformance validation of new high precision CH4 and CO2 analyzers based on optical feedback cavity enhanced absorption spectroscopy

Trace Gas Poster iconMethane and Carbon Dioxide Measurements with New High-Precision Low-Power Low-Maintenanace Closed-Path Analyzers: First Lab and Field Results

Trace Gas Poster iconChamber-based Soil Methane Flux Measurement

Trace Gas Poster iconMeasuring CH4 and CO2 with New Generation High-Precision Low-Power Low-Maintenance Closed-Path Analyzers: Lab and Field Results

Related Products

Monitors indoor light changes with an internal sensor and records light on/off conditions; ideal for building energy audits and light usage analysis.
Monitors indoor light changes with an internal sensor and records light on/off conditions; ideal for building energy audits and light usage analysis.
The LI-193 Spherical Quantum Sensor measures PAR in air or underwater from all directions at depths up to 350 meters. This sensor is useful for studies of phytoplankton, which uses radiation from …
The LI-193 Spherical Quantum Sensor measures PAR in air or underwater from all directions at depths up to 350 meters. This sensor is useful for studies of phytoplankton, which uses radiation from …
Measures and transmits temperature, relative humidity, and light intensity data wirelessly.
Measures and transmits temperature, relative humidity, and light intensity data wirelessly.
The HOBO TidbiT MX2205 is ideal for monitoring shallow waters, like streams and wetlands, or for monitoring soil in fields that are prone to flooding.
The HOBO TidbiT MX2205 is ideal for monitoring shallow waters, like streams and wetlands, or for monitoring soil in fields that are prone to flooding.
The LI-870 delivers rapid CO2 flux measurements with great precision while being light enough (2.31 kg) to carry all day without wearing you out.
The LI-870 delivers rapid CO2 flux measurements with great precision while being light enough (2.31 kg) to carry all day without wearing you out.
Measures and records CO2 in buildings and other non-condensing environments.
Measures and records CO2 in buildings and other non-condensing environments.
The 8200-104 Opaque Long-Term Chamber accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.
The 8200-104 Opaque Long-Term Chamber accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.
Monitors room occupancy and indoor light changes to identify occupancy patterns and determine energy usage and potential savings.
Monitors room occupancy and indoor light changes to identify occupancy patterns and determine energy usage and potential savings.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

LI-7815
Trace Gas Analyzers
LI-7815
Trace Gas Analyzers