ASTM D7169, D7900, IP 545, IP 601, EN 15199-3, EN 15199-4

The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis. Standardization committees such as ASTM, IP and CEN are developing methods to allow the merging of a separate DHA analysis of the front end of a crude oil with the high temperature SIMDIS analysis. As a result of this merge, more accurate boiling point range data is obtained allowing precise cut point intervals determination for the whole crude oil. This allows for modeling end product closer to specs and ultimately less product give-away, while still meeting stringent product specifications.
The Crude Oil Analyzer (ASTM D7169) is the official standard for determination of the boiling point distribution and cut point intervals of crude oils and residues by using high temperature gas chromatography.

ApplicationsCrude

Key Industries: Chemicals, Oil and Gas and more.

PAC AC Crude Oil Analyzer Philippines

More Accurate Whole Crude Oil Analysis Optimizes Product Value

  • Based on high resolution DHA analysis to separate individual components for the light end of the crude oil up to and including C9 without quenching
  • Uses HT SIMDIS for the heavier components >C9 according to ASTM D7169
  • Built-in calculations ensure the amount residue (or sample recovery) is determined using an external standard
  • Intuitive AC software merges DHA and SIMDIS results into one boiling point distribution curve for the whole crude oil
  • Unique AC User Group with performance monitoring program (PMP)
  • Includes certified AC Quality Control Samples dedicated to crude oil

Proven Compliancy

  • Compliant with ASTM D7169, IP 545, IP 601 and EN 15199-3
  • Optional unique combi inlet allows analysis of both light end in crude oil (DHA FE) and light petroleum streams (naphtha/gasoline) conform ASTM D6729, D6730, D6733 and D5134
Crude Oil Analyzer

For more information, contact us.

Features

More Accurate Whole Crude Oil Analysis Optimizes Product Value

  • Based on high resolution DHA analysis to separate individual components for the light end of the crude oil up to and including C9 without quenching
  • Uses HT SIMDIS for the heavier components >C9 according to ASTM D7169
  • Built-in calculations ensure the amount residue (or sample recovery) is determined using an external standard
  • Intuitive AC software merges DHA and SIMDIS results into one boiling point distribution curve for the whole crude oil
  • Unique AC User Group with performance monitoring program (PMP)
  • Includes certified AC Quality Control Samples dedicated to crude oil

Proven Compliancy

  • Compliant with ASTM D7169, IP 545, IP 601 and EN 15199-3
  • Optional unique combi inlet allows analysis of both light end in crude oil (DHA FE) and light petroleum streams (naphtha/gasoline) conform ASTM D6729, D6730, D6733 and D5134

Related Products

Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
ElemeNtS is the most advanced, modular, analytical system which detects Total Sulfur and/or Total Nitrogen efficiently using Ultraviolet Fluorescence (UVF) and Chemiluminescence (CLD) in solid, liquid
The AC Analytical Controls® standard solutions cover a wide spectrum of petroleum, petrochemical, and natural gas analysis needs.
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
PAC provides complete, turn-key gas chromatographic solutions for accurate determination of true boiling point data – from naphtha up to crude oil samples.
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.
The HDV 632 is a fully automated Vacuum Distillation Analyzer, which offers highest flexibility for the user. It can measure samples up to 650C AET.
Herzog’s HVP 972 Vapor Pressure Analyzer is the modern analytical instrument designed for accurate determination of vapor pressure.
Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

Crude Oil Analyzer
Crude Oil Analyzer