ASTM D7169, D7900, IP 545, IP 601, EN 15199-3, EN 15199-4

The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis. Standardization committees such as ASTM, IP and CEN are developing methods to allow the merging of a separate DHA analysis of the front end of a crude oil with the high temperature SIMDIS analysis. As a result of this merge, more accurate boiling point range data is obtained allowing precise cut point intervals determination for the whole crude oil. This allows for modeling end product closer to specs and ultimately less product give-away, while still meeting stringent product specifications.
The Crude Oil Analyzer (ASTM D7169) is the official standard for determination of the boiling point distribution and cut point intervals of crude oils and residues by using high temperature gas chromatography.

ApplicationsCrude

Key Industries: Chemicals, Oil and Gas and more.

PAC AC Crude Oil Analyzer Philippines

More Accurate Whole Crude Oil Analysis Optimizes Product Value

  • Based on high resolution DHA analysis to separate individual components for the light end of the crude oil up to and including C9 without quenching
  • Uses HT SIMDIS for the heavier components >C9 according to ASTM D7169
  • Built-in calculations ensure the amount residue (or sample recovery) is determined using an external standard
  • Intuitive AC software merges DHA and SIMDIS results into one boiling point distribution curve for the whole crude oil
  • Unique AC User Group with performance monitoring program (PMP)
  • Includes certified AC Quality Control Samples dedicated to crude oil

Proven Compliancy

  • Compliant with ASTM D7169, IP 545, IP 601 and EN 15199-3
  • Optional unique combi inlet allows analysis of both light end in crude oil (DHA FE) and light petroleum streams (naphtha/gasoline) conform ASTM D6729, D6730, D6733 and D5134
Crude Oil Analyzer

For more information, contact us.

Features

More Accurate Whole Crude Oil Analysis Optimizes Product Value

  • Based on high resolution DHA analysis to separate individual components for the light end of the crude oil up to and including C9 without quenching
  • Uses HT SIMDIS for the heavier components >C9 according to ASTM D7169
  • Built-in calculations ensure the amount residue (or sample recovery) is determined using an external standard
  • Intuitive AC software merges DHA and SIMDIS results into one boiling point distribution curve for the whole crude oil
  • Unique AC User Group with performance monitoring program (PMP)
  • Includes certified AC Quality Control Samples dedicated to crude oil

Proven Compliancy

  • Compliant with ASTM D7169, IP 545, IP 601 and EN 15199-3
  • Optional unique combi inlet allows analysis of both light end in crude oil (DHA FE) and light petroleum streams (naphtha/gasoline) conform ASTM D6729, D6730, D6733 and D5134

Related Products

The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
Phase Technology’s new JFA-70Xi jet fuel analyzer is the world’s first and only instrument that performs three crucial tests in one unit—freeze point, viscosity and density. And, it does it all in les
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
Results are not only fast, but also highly precise and accurate. The user interface is so simple it doesn’t require any training which saves time and money.
Our new DTOT which is suitable for several blends of diesel fuel like Pure Diesel (B0), Diesel Fuel with 7% FAME (B7) and Diesel Fuel with 20% FAME (B20).
The AC Analytical Controls Biodiesel All in One Analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single system
The Herzog 915 & 917 Gum Testers are designed to measure evaporation residue in aviation fuels, motor gasolines, and other volatile distillates.
The ACCURA sampling device is designed for fully automated analysis of gaseous and pressurized liquid hydrocarbon streams for MultiTek and Gas Chromatography applications.
Alcor’s MCRT-160 provides safe measurements of petroleum products with a tendency to thermally degrade and form coke under high temperature pyrolyzing conditions.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

Crude Oil Analyzer
Crude Oil Analyzer