Houillon Viscometers

VH1 & VH2

ASTM D7279, ASTM D2270

Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity range. Initially developed for lubricant blending facilities, research laboratories, and used oil monitoring where small sample size and quick results were required, the ISL VH viscometer offers exceptional performance, providing results in 60 seconds using less than 1 ml of sample.

The VH series of viscometers include:

  • Model VH1: integrates a single solvent capacity for tube cleaning
  • Model VH2: accommodates two solvents, offering added flexibility in solvent selection for efficient tube cleaning and drying and withstands the use of aggressive solvents

ASTM D7279, ASTM D2270

Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity range. Initially developed for lubricant blending facilities, research laboratories, and used oil monitoring where small sample size and quick results were required, the ISL VH viscometer offers exceptional performance, providing results in 60 seconds using less than 1 ml of sample.

The VH series of viscometers include:

  • Model VH1: integrates a single solvent capacity for tube cleaning
  • Model VH2: accommodates two solvents, offering added flexibility in solvent selection for efficient tube cleaning and drying and withstands the use of aggressive solvents
  • Modular design with ultimate configuration flexibility enables up to 16 simultaneous test runs
  • High throughput with complete results in minutes; can complete up to 75 tests per hour
  • Easy constant calibration with reference fluids
  • Reduce waste with small sample size; uses less than 1 ml
  • Multi-instrument networking and PC-based data management
  • Saves calibration parameters for multiple bath temperature settings
  • Automated cleaning system, individually programmable for each tube

Related Products

Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
The AC Analytical Controls Biodiesel All in One Analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single system
The AC Analytical Controls Biodiesel All in One Analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single system
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
The VIDA ML density meter is specifically designed for mobile laboratory applications providing accurate and repeatable density.
The VIDA ML density meter is specifically designed for mobile laboratory applications providing accurate and repeatable density.
OptiFuel comes in a rugged yet elegant design with a friendly user interface, which makes it ideal for refineries, pipelines, terminals, and mobile labs.
OptiFuel comes in a rugged yet elegant design with a friendly user interface, which makes it ideal for refineries, pipelines, terminals, and mobile labs.
ElemeNtS is the most advanced, modular, analytical system which detects Total Sulfur and/or Total Nitrogen efficiently using Ultraviolet Fluorescence (UVF) and Chemiluminescence (CLD) in solid, liquid
ElemeNtS is the most advanced, modular, analytical system which detects Total Sulfur and/or Total Nitrogen efficiently using Ultraviolet Fluorescence (UVF) and Chemiluminescence (CLD) in solid, liquid
The Herzog OptiFlash Pensky Martens determines the flash point of petroleum products, biodiesels, solvents, fluxed bitumen, food, and beverages up to 400°C.
The Herzog OptiFlash Pensky Martens determines the flash point of petroleum products, biodiesels, solvents, fluxed bitumen, food, and beverages up to 400°C.
The WAT-70Xi is the world’s first and only totally automatic process to measure WAT and WDT of crudes and marine fuel, capable of performing reliable testing of VLSFO and residual black oils.
The WAT-70Xi is the world’s first and only totally automatic process to measure WAT and WDT of crudes and marine fuel, capable of performing reliable testing of VLSFO and residual black oils.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

VH1 & VH2
Houillon Viscometers
VH1 & VH2
Houillon Viscometers