Hi-Speed RGA - Refinery Gas Component

ASTM D2163, ASTM D2504, ASTM D2505, ASTM D2598, ASTM D3588, EN ISO 7941, IP 405, ISO 7941, EN 15984, DIN 51666, ASTM D1946, UOP 539, GOST 31371

The AC Hi-Speed RGA system characterizes:

  • C1 - nC6, C6+ hydrocarbons
  • Inert gases: nitrogen, hydrogen, helium, oxygen, carbon monoxide, carbon dioxide
  • Hydrogen sulfide
  • BTEX (benzene, Toluene, Ethylbenzene,Xylenes), using the RGA extended method with a total analysis time under thirty minutes
  • LPG and butane streams. Optionally, the system can also be configured for hydrocarbon trace analysis.


Applications:
Applicated GC Gas Analysis, Refinery Gas Analysis

ASTM D2163, ASTM D2504, ASTM D2505, ASTM D2598, ASTM D3588, EN ISO 7941, IP 405, ISO 7941, EN 15984, DIN 51666, ASTM D1946, UOP 539, GOST 31371

The AC Hi-Speed RGA system characterizes:

  • C1 – nC6, C6+ hydrocarbons
  • Inert gases: nitrogen, hydrogen, helium, oxygen, carbon monoxide, carbon dioxide
  • Hydrogen sulfide
  • BTEX (benzene, Toluene, Ethylbenzene,Xylenes), using the RGA extended method with a total analysis time under thirty minutes
  • LPG and butane streams. Optionally, the system can also be configured for hydrocarbon trace analysis.


Applications:
Applicated GC Gas Analysis, Refinery Gas Analysis

PAC Hi-Speed RGA – Refinery Gas Analyzer Philippines

Features & Benefits

  • Performs analysis in 5 minutes
  • Applies to a broad sample scope of both gaseous and liquefied samples
  • Excellent repeatability through automated sample shutoff valve and sampling devices
  • Robust and cost-effective design with valves mounted on the dedicated left side to provide superior thermal control, leak free operation, and easy access
  • Automatically calculates gas properties with the AC GASXLNC™ software
  • Optional special unit to introduce gas samples, which provides an easy and leak free connection to the instrument
  • Refinery gas streams vary considerably in composition. Determining individual components of each gas stream is a challenge. An exact measure of stream components is essential in achieving optimum control and assuring product quality. PAC’s AC Analytical Controls offers the Hi-Speed Refinery Gas Analyzer, a high speed solution that determines and reports the composition of refinery gas streams in only five minutes.

    NEW!! The AC Hi-Speed Refinery Gas Analyzer is now available on the new Agilent 8890 GC Platform. Intelligent capabilities built into the Agilent 8890 GC give you the freedom to work with your GC… not on it. These capabilities can also grow over time as your analytical needs change—so you can keep your lab moving toward a successful future.

For more information, contact us.

Related Products

The Optiflash accurately detects flashpoint from -30°C up to 300°C for petroleum products, biodiesels, solvents, chemicals, paint varnishes, fluxed bitumen and food and beverages.
The Optiflash accurately detects flashpoint from -30°C up to 300°C for petroleum products, biodiesels, solvents, chemicals, paint varnishes, fluxed bitumen and food and beverages.
The WAT-70Xi is the world’s first and only totally automatic process to measure WAT and WDT of crudes and marine fuel, capable of performing reliable testing of VLSFO and residual black oils.
The WAT-70Xi is the world’s first and only totally automatic process to measure WAT and WDT of crudes and marine fuel, capable of performing reliable testing of VLSFO and residual black oils.
The AC Analytical Controls® standard solutions cover a wide spectrum of petroleum, petrochemical, and natural gas analysis needs.
The AC Analytical Controls® standard solutions cover a wide spectrum of petroleum, petrochemical, and natural gas analysis needs.
The ViscoLab 4000 is a small sample viscometer which supports up to 12 different 20:1 viscosity ranges; up to 10,000 cP with several output options.
The ViscoLab 4000 is a small sample viscometer which supports up to 12 different 20:1 viscosity ranges; up to 10,000 cP with several output options.
Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

Hi-Speed RGA – Refinery Gas Component
Hi-Speed RGA - Refinery Gas Component