Sampling Device

ACCURA

The ACCURA sampling device is designed for fully automated analysis of gaseous and pressurized liquid hydrocarbon streams for MultiTek and Gas Chromatography applications. It provides these key benefits through:

  • Highest accuracy and precision through uncompromised sample integrity
  • Easy to use
  • Maximum operator safety
  • Can be used for MultiTek and GC, gas and liquids
  • Repeated injections in one run (MultiTek only)

When analyzing Liquid Pressurized Gases (LPG) with Gas Chromatography or Elemental Analysis, the most challenging task is to maintain sample integrity. Uncontrolled expansion of pressurized or liquefied gases often leads to discrimination: the perceived sample composition changes.

Accura is a temperature and pressure controlled vaporizing injection device that respects sample integrity completely. The resulting data are more accurate and precise, which translates in a narrower product specification and better refining profit.

LPG and hydrocarbon gases are extremely flammable and therefore need to be handled with great care. Accura identifies when sample lines are depressurized after analysis, signaling the sample bomb can be disconnected safely.

Applications: Sulfur, Nitrogen, Nitrogen & Sulfur, Nitrogen & Halides, Sulfur & Halides, Nitrogen & Sulfur & Halides, Applicated GC Gas Analysis, Natural Gas Analysis, Refinery Gas Analysis, Sulfur Trace Analysis, Customized Analysis.

Excellent Performance

  • Highest accuracy and precision. The controlled vaporization ensures uncompromised sample integrity. More accurate data translates into refining profit
  • Complete Sulfinert Sample Path
  • Repeated injections in one analysis (MultiTek only)


Maximum Operator’s Safety

  • Accura will flag line pressure to operator, signaling it is safe to remove sample canister. This avoids human error and adds to lab safety.


Improved Ease of Use and More Flexibility

  • Connect Sample, select sample type and start
  • A clear LCD displays all required information on pressures and flows for easy access
  • Accura will store relevant information with Timestamp
  • Accura can interface to Multitek and 9000 models for Elemental analyses
  • Accura can interface to 6850, 7890A and 7890B Gas Chromatographs

Proven Compliancy

  • Accura is in line with current going methods using chromatography and elemental analysis for LPG and pressurized gases
Features

Excellent Performance

  • Highest accuracy and precision. The controlled vaporization ensures uncompromised sample integrity. More accurate data translates into refining profit
  • Complete Sulfinert Sample Path
  • Repeated injections in one analysis (MultiTek only)


Maximum Operator’s Safety

  • Accura will flag line pressure to operator, signaling it is safe to remove sample canister. This avoids human error and adds to lab safety.


Improved Ease of Use and More Flexibility

  • Connect Sample, select sample type and start
  • A clear LCD displays all required information on pressures and flows for easy access
  • Accura will store relevant information with Timestamp
  • Accura can interface to Multitek and 9000 models for Elemental analyses
  • Accura can interface to 6850, 7890A and 7890B Gas Chromatographs

Proven Compliancy

  • Accura is in line with current going methods using chromatography and elemental analysis for LPG and pressurized gases

Related Products

ISL’s OptiCPP performs pour and/cloud point testing of any petroleum products, down to -95°C (-139°F), in accordance with all international standards.
The ViscoLab 3000 is a temperature-controlled viscometer that features an integrated heater to accurately deliver measurements at user-defined temperatures.
ISL’s automated Mini Cloud Pour Point Analyzer is compact, portable and delivers fast results (30C in less than 30 minutes, and quick pour point correlation)
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.
Safe, easy to use ISL’s NCK2 5G Noack evaporation loss analyzer enables the most precise testing possible to meet increasing QS/QA requirements in full compliance with CEC, ASTM & IP methods.
PAC’s AC offers full range of Detailed Hydrocarbon Analyzers (DHA) to determine individual hydrocarbon composition in light hydrocarbon streams, gasoline blending feedstocks, spark ignition engine fue
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.
Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
PAC provides complete, turn-key gas chromatographic solutions for accurate determination of true boiling point data – from naphtha up to crude oil samples.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

ACCURA
Sampling Device
ACCURA
Sampling Device