In the last decade, there has been a worldwide growth in the interest for alternative fuels. Biodiesel Fatty Acid Methyl Esters (FAMEs) offer an alternative to fossil diesel fuel. FAME can be blended with petroleum diesel (mostly B5, B7 and B20) or used as pure biodiesel (B100).

The AC Analytical Controls Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. The analyzer is completely tested and calibrated according to specified methods and includes multiple sets of calibration components, internal standards, and reagents.

The Biodiesel All in One analyzer covers all the current chromatographic tests listed for the specification methods in one system (see below table).

BioDiesel All-in-One Solution Analysis Methods
MethodsAnalysisInletAnalysis Time
ASTM D6584Free & total glycerinOn-column (TPI)35 minutes
EN 14103
prEN16300
Ester and linolenic acid methyl ester content
Iodine Value
Split/splitless25 minutes
EN 14105Free & total glycerol, mono-, di-, and triglyceride contentOn-column (TPI)35 minutes
EN 14110Methanol contentSplit/splitless10 minutes

The AC Biodiesel All in One Analyzer uses a single Agilent 7890A Series GC with electronic pneumatics control (EPC), an AC proprietary TPI inlet, a Split/Splitless inlet, two capillary columns, one programmable external capillary column oven, and two Flame Ionization Detectors.

Applications: BioFuels

In the last decade, there has been a worldwide growth in the interest for alternative fuels. Biodiesel Fatty Acid Methyl Esters (FAMEs) offer an alternative to fossil diesel fuel. FAME can be blended with petroleum diesel (mostly B5, B7 and B20) or used as pure biodiesel (B100).

The AC Analytical Controls Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. The analyzer is completely tested and calibrated according to specified methods and includes multiple sets of calibration components, internal standards, and reagents.

The Biodiesel All in One analyzer covers all the current chromatographic tests listed for the specification methods in one system (see below table).

BioDiesel All-in-One Solution Analysis Methods
MethodsAnalysisInletAnalysis Time
ASTM D6584Free & total glycerinOn-column (TPI)35 minutes
EN 14103
prEN16300
Ester and linolenic acid methyl ester content
Iodine Value
Split/splitless25 minutes
EN 14105Free & total glycerol, mono-, di-, and triglyceride contentOn-column (TPI)35 minutes
EN 14110Methanol contentSplit/splitless10 minutes

The AC Biodiesel All in One Analyzer uses a single Agilent 7890A Series GC with electronic pneumatics control (EPC), an AC proprietary TPI inlet, a Split/Splitless inlet, two capillary columns, one programmable external capillary column oven, and two Flame Ionization Detectors.

Applications: BioFuels

High throughput, small footprint

  • Features a short analysis time
  • Automates analysis with an optional Automatic Liquid Sampler
  • Combines all relevant biodiesel applications within one flexible system for a complete biodiesel solution


Innovative system design

  • Decreases operator intervention with the secondary programmable column oven – no need for the removal of columns or other hardware when switching applications
  • Guarantees excellent long term results
  • Increases productivity to no down-time for column replacement or other maintenance
  • Decreases costs due to time savings on operator time and spare parts
  • Improves system up time in the lab

Meets standards

  • Complies with the latest updates from ASTM D6584, EN 14103, EN 14105, EN 14110 methods
  • Complies with and prEN 16300 for Iodine Value

Enhanced and user-friendly software

  • Reports all relevant information for each method
  • Calculates with no need for additional programming
  • Checks data against specification (pass/fail)
  • Ensures traceability through calibration data
  • Automates column performance checks for easy quality control

Enhanced features

  • Includes all calibration components, internal standards, and reagents for each method
  • Installs easily, and a qualified support engineer handles installation system on-site and familiarizes users with operation

Related Products

Results are not only fast, but also highly precise and accurate. The user interface is so simple it doesn’t require any training which saves time and money.
Results are not only fast, but also highly precise and accurate. The user interface is so simple it doesn’t require any training which saves time and money.
Herzog’s HVP 972 Vapor Pressure Analyzer is the modern analytical instrument designed for accurate determination of vapor pressure.
Herzog’s HVP 972 Vapor Pressure Analyzer is the modern analytical instrument designed for accurate determination of vapor pressure.
The next generation Freeze Point Analyzer offers proven technology used by labs worldwide. The powerful internal cooling system can measure up to -100C (-148F) without the need of an external cooling
The next generation Freeze Point Analyzer offers proven technology used by labs worldwide. The powerful internal cooling system can measure up to -100C (-148F) without the need of an external cooling
The Optiflash accurately detects flashpoint from -30°C up to 300°C for petroleum products, biodiesels, solvents, chemicals, paint varnishes, fluxed bitumen and food and beverages.
The Optiflash accurately detects flashpoint from -30°C up to 300°C for petroleum products, biodiesels, solvents, chemicals, paint varnishes, fluxed bitumen and food and beverages.
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
ISL’s OptiCPP performs pour and/cloud point testing of any petroleum products, down to -95°C (-139°F), in accordance with all international standards.
ISL’s OptiCPP performs pour and/cloud point testing of any petroleum products, down to -95°C (-139°F), in accordance with all international standards.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

BioDiesel All-in-One
BioDiesel All-in-One