In the last decade, there has been a worldwide growth in the interest for alternative fuels. Biodiesel Fatty Acid Methyl Esters (FAMEs) offer an alternative to fossil diesel fuel. FAME can be blended with petroleum diesel (mostly B5, B7 and B20) or used as pure biodiesel (B100).

The AC Analytical Controls Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. The analyzer is completely tested and calibrated according to specified methods and includes multiple sets of calibration components, internal standards, and reagents.

The Biodiesel All in One analyzer covers all the current chromatographic tests listed for the specification methods in one system (see below table).

BioDiesel All-in-One Solution Analysis Methods
Methods Analysis Inlet Analysis Time
ASTM D6584 Free & total glycerin On-column (TPI) 35 minutes
EN 14103
prEN16300
Ester and linolenic acid methyl ester content
Iodine Value
Split/splitless 25 minutes
EN 14105 Free & total glycerol, mono-, di-, and triglyceride content On-column (TPI) 35 minutes
EN 14110 Methanol content Split/splitless 10 minutes

The AC Biodiesel All in One Analyzer uses a single Agilent 7890A Series GC with electronic pneumatics control (EPC), an AC proprietary TPI inlet, a Split/Splitless inlet, two capillary columns, one programmable external capillary column oven, and two Flame Ionization Detectors.

Applications: BioFuels

In the last decade, there has been a worldwide growth in the interest for alternative fuels. Biodiesel Fatty Acid Methyl Esters (FAMEs) offer an alternative to fossil diesel fuel. FAME can be blended with petroleum diesel (mostly B5, B7 and B20) or used as pure biodiesel (B100).

The AC Analytical Controls Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. The analyzer is completely tested and calibrated according to specified methods and includes multiple sets of calibration components, internal standards, and reagents.

The Biodiesel All in One analyzer covers all the current chromatographic tests listed for the specification methods in one system (see below table).

BioDiesel All-in-One Solution Analysis Methods
Methods Analysis Inlet Analysis Time
ASTM D6584 Free & total glycerin On-column (TPI) 35 minutes
EN 14103
prEN16300
Ester and linolenic acid methyl ester content
Iodine Value
Split/splitless 25 minutes
EN 14105 Free & total glycerol, mono-, di-, and triglyceride content On-column (TPI) 35 minutes
EN 14110 Methanol content Split/splitless 10 minutes

The AC Biodiesel All in One Analyzer uses a single Agilent 7890A Series GC with electronic pneumatics control (EPC), an AC proprietary TPI inlet, a Split/Splitless inlet, two capillary columns, one programmable external capillary column oven, and two Flame Ionization Detectors.

Applications: BioFuels

High throughput, small footprint

  • Features a short analysis time
  • Automates analysis with an optional Automatic Liquid Sampler
  • Combines all relevant biodiesel applications within one flexible system for a complete biodiesel solution


Innovative system design

  • Decreases operator intervention with the secondary programmable column oven – no need for the removal of columns or other hardware when switching applications
  • Guarantees excellent long term results
  • Increases productivity to no down-time for column replacement or other maintenance
  • Decreases costs due to time savings on operator time and spare parts
  • Improves system up time in the lab

Meets standards

  • Complies with the latest updates from ASTM D6584, EN 14103, EN 14105, EN 14110 methods
  • Complies with and prEN 16300 for Iodine Value

Enhanced and user-friendly software

  • Reports all relevant information for each method
  • Calculates with no need for additional programming
  • Checks data against specification (pass/fail)
  • Ensures traceability through calibration data
  • Automates column performance checks for easy quality control

Enhanced features

  • Includes all calibration components, internal standards, and reagents for each method
  • Installs easily, and a qualified support engineer handles installation system on-site and familiarizes users with operation

Related Products

The next generation Freeze Point Analyzer offers proven technology used by labs worldwide. The powerful internal cooling system can measure up to -100C (-148F) without the need of an external cooling
The next generation Freeze Point Analyzer offers proven technology used by labs worldwide. The powerful internal cooling system can measure up to -100C (-148F) without the need of an external cooling
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
OptiDist is the benchmark in atmospheric distillation testing offering the highest level of precision. Its a state-of-the-art optimal solution for performing atmospheric distillation.
OptiDist is the benchmark in atmospheric distillation testing offering the highest level of precision. Its a state-of-the-art optimal solution for performing atmospheric distillation.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

BioDiesel All-in-One
BioDiesel All-in-One