MICAP-OES 1000 Plasma Source

Unique Design
Unique Performance

Optical Emission Spectrometer
Echelle spectrometer simultaneously measures the entire wavelength range with every solution injection.

Wavelength range: 194 nm – 625 nm + 766 nm

Resolution 5pm – 30 pm, 7 pm at 200 nm

Annual CO2e Emissions Savings Compared to Argon Carbon Footprint

Unique Design
Unique Performance

Optical Emission Spectrometer
Echelle spectrometer simultaneously measures the entire wavelength range with every solution injection.

Wavelength range: 194 nm – 625 nm + 766 nm

Resolution 5pm – 30 pm, 7 pm at 200 nm

Annual CO2e Emissions Savings Compared to Argon Carbon Footprint

MICAP OES 1000 Plasma Source

Product Specification

Variable speed four-channel peristaltic pump and concentric 1 mL/min nebulizer are standard sample introduction assembly (SIA) components.

Vertical torch position with axial viewing and automated, uniform plasma tail removal.

Echelle Spectrometer simultaneously measures the entire wavelength range with every solution injection.

Power requirements:

  • Mains power: 208 V to 240 V/10 A
  • No water cooling required

Exhaust:

  • 4 inch (100 mm) exhaust with flow rate between 100 – 200 cfm (1.5 – 2.9 m/s)

Gas flows:

  • Mass flow controlled coolant, auxillary and nebulizer gas for reliable and stable sample measurement
  • Typical plasma gas flow is 14L/min
  • Nitrogen gas can be sourced from liquid dewar, compressed gas cylinder or nitrogen generator

Size:

  • [W] 20.7 in (525 mm) x [H] 22 in (560 mm) x [D] 14 in (350 mm)

Weight:

  • MICAP Plasma Source Unit 42 lbs (19 kg)
  • Total weight of MICAP with Spectrometer 67 lbs (30 kg)

Camera

Detector

  • sCMOS

Array diagonal:

  • 31 mm

Resolution:

  • 2048 x 2048

Cooling:

  • Peltier cooled to -10 °C

Other parameters:

  • Pixel size: 11 µm x 11 µm
  • Frame rate: 24 fps

Optical Emission Spectrometer of OES 1000 Plasma Source

Wavelength range:

  • Simultaneous measurement 194 nm – 625 nm + 766 nm

Slit Width:

  • 30 um slit

Resolution:

  • 5pm – 30 pm, 7 pm at 200 nm

Operating environment:

  • Temperature: 20 – 25 °C (68 – 77 °F)
  • Relative Humidity: 20-60 %

Key Design Features

  • Simplified architecture with Methods for conditions and Sessions for running samples
  • Detailed peak viewing with quick peak integration settings
  • Spectral database to highlight potential spectral overlaps
  • Live time scan for sample introduction optimization

Key Performance Features

  • AI-powered spectral processing
  • Continuous Nitrogen background correction
  • Simultaneous data capture allows application of internal standardization in high matrix samples
  • Full spectrum capture provides alternate line addition
  • Delivers full analysis flexibility post-acquisition

OES 1000 Plasma Source

OES 1000 Plasma Source

For more informationcontact us.

Click here.

Application Note: Lubricant Oil Analysis for Wear Metals, Additives, and Ingress Elements

Application Note – MICAP OES Lubricant Oil

Related Products

The MESA-7220V2 measures both sulfur and chlorine in petroleum based products using the Monochromatic Energy Dispersive X-ray Fluorescence (EDXRF) method.
The MESA-7220V2 measures both sulfur and chlorine in petroleum based products using the Monochromatic Energy Dispersive X-ray Fluorescence (EDXRF) method.
DSC is used to measure heat flow for material characterization by providing thermal properties such as melting point, glass transition and crystallization.
DSC is used to measure heat flow for material characterization by providing thermal properties such as melting point, glass transition and crystallization.
Hitachi offers high-precision background correction and high-sensitivity measurement by employing the polarized Zeeman correction method alongside the dual detector method.
Hitachi offers high-precision background correction and high-sensitivity measurement by employing the polarized Zeeman correction method alongside the dual detector method.
The Coulometric Karl Fischer Titrator offers an 8.4-inch touch LCD, adjustable display angles, USB data management, a thermal printer, and simultaneous measurement of up to 4 moisture types.
The Coulometric Karl Fischer Titrator offers an 8.4-inch touch LCD, adjustable display angles, USB data management, a thermal printer, and simultaneous measurement of up to 4 moisture types.
Standard torch dimensions (20 mm) with 1.5 mm injector (2.5 mm injector option) designed around the fixed position torch holder assembly.
Standard torch dimensions (20 mm) with 1.5 mm injector (2.5 mm injector option) designed around the fixed position torch holder assembly.
The AminoSAAYA offers easy and comfortable operability while maintaining the reliability and stability of Hitachi’ s legacy amino acid analyzers.
The AminoSAAYA offers easy and comfortable operability while maintaining the reliability and stability of Hitachi’ s legacy amino acid analyzers.
High-Performance Liquid Chromatography (HPLC) is utilized in a wide range of fields, such as medicine, food production, chemistry, and environmental science, making the demand for HPLC systems higher
High-Performance Liquid Chromatography (HPLC) is utilized in a wide range of fields, such as medicine, food production, chemistry, and environmental science, making the demand for HPLC systems higher
Optimise sample preparation with SimPrep. Perform dilutions, dosing, and standard additions with precision, staying within 1% of the target volume.
Optimise sample preparation with SimPrep. Perform dilutions, dosing, and standard additions with precision, staying within 1% of the target volume.