High Energy Excimer Laser Ablation System

​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​Analyte HE

  • Coherent COMPexPro Laser

  • High Energy Density at the Sample

  • UV Transparent Materials

  • Fine Fluence Control​​​

​​​​​​​​​​​​​​​​The Analyte HE Laser Ablation System​​ offers excimer technology at 193 nm with all the analytical capabilities you require, delivering finely controlled, “homogenized-flat” ablations with high sensitivity and split second response. “Fire-on-the-fly” lasing that is synchronized to the stage motion, combined with fast washout ablation cells, make precision depth profiling of spots, lines and areas possible and enables high spatial resolution elemental mapping.

  • Ultra-short 193 nm wavelength
  • Up to 50 J/cm2 fluence ablates all materials, including quartz and fluorite
  • Optical homogenization of the laser beam for uniform flat ablations
  • Sealed gas cabinet
  • 100 × 100 mm stage travel as standard, 150 x 150 travel option available
  • Synchronized “fire-on-the-fly” lasing for the ultimate depth control during ablation
  • Independent video and lasing optical element for optimal viewing and crater quality
  • Aperture imaged spots ranging from 2 μm to 175 μm
  • 30 apertures as standard; custom masks available
  • HelEx II active 2-volume ablation cell as standard​

Laser Ablation System | The Teledyne Analyte HE Laser Ablation System​​ offers excimer technology at 193 nm with all the analytical capabilities you require, delivering finely controlled, “homogenized-flat” ablations. Inquire at Sigmatech Inc.

Laser Ablation System
Analyte HE High Energy Excimer Laser Ablation System
Features

​​​​​​​​The Analyte HE Laser Ablation System​​ offers excimer technology at 193 nm with all the analytical capabilities you require, delivering finely controlled, “homogenized-flat” ablations with high sensitivity and split second response. “Fire-on-the-fly” lasing that is synchronized to the stage motion, combined with fast washout ablation cells, make precision depth profiling of spots, lines and areas possible and enables high spatial resolution elemental mapping.

  • Ultra-short 193 nm wavelength
  • Up to 50 J/cm2 fluence ablates all materials, including quartz and fluorite
  • Optical homogenization of the laser beam for uniform flat ablations
  • Sealed gas cabinet
  • 100 × 100 mm stage travel as standard, 150 x 150 travel option available
  • Synchronized “fire-on-the-fly” lasing for the ultimate depth control during ablation
  • Independent video and lasing optical element for optimal viewing and crater quality
  • Aperture imaged spots ranging from 2 μm to 175 μm
  • 30 apertures as standard; custom masks available
  • HelEx II active 2-volume ablation cell as standard​

Related Products

The LA-960 combines the most popular modern sizing technique with state of the art refinements to measure wet and dry samples measuring 10 nanometers to 5 millimeters.
Standard torch dimensions (20 mm) with 1.5 mm injector (2.5 mm injector option) designed around the fixed position torch holder assembly.
Your lab-in-a-pocket. Horiba LAQUAtwin’s unique pocket meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop
The Iridia Laser Ablation System​ is a purpose-built laser ablation system designed for ultimate flexibility and capable of addressing an increasing range of demanding applications.
DSC is used to measure heat flow for material characterization by providing thermal properties such as melting point, glass transition and crystallization.
U-2900/2910 is a Double Beam Spectrophotometer mounting a large-size color LCD, which is simpler to use and higher in dependability.
The Teledyne LABS ASXpress® Plus Rapid Sample Injection System reduces the time required for autosampler movement, sample uptake, stabilization, and rinse operations with ICP-OES and ICP-MS. The resul
Manual Hydraulic Presses are available in 15 and 25 Ton load configurations and are intended for a wide range of laboratory press applications.
The Lotix Combustion TOC analyzer is designed to accurately measure carbon content in aqueous matrices down to the ppb level.
With the highest level for 3D fluorescence spectra, F-7100 can be used in a wide range of applications from the cutting edge research to quality control.​

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​Analyte HE
High Energy Excimer Laser Ablation System
​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​Analyte HE
High Energy Excimer Laser Ablation System