A full automation solution for routine analysis of waters by purge and trap concentration

A full automation solution for routine analysis of waters by purge and trap concentration

The AQUATek LVA is a fully automated system for water analysis using purge and trap concentration. It ensures compliance with USEPA methods for VOCs through a closed-system design and vial cooling, preserving sample integrity and reducing VOC loss. Featuring a compact, stackable design, it integrates seamlessly with compatible concentrators like the Lumin or Stratum PTC, with a cleanup cycle using 90°C water for efficient maintenance.

Features

  • Sample Loop – The AQUATek LVA is equipped with a fixed volume PEEK™ sample loop with volume choices of 5, 10, 20 and 25 mL. The sample loop is filled with a liquid sample from the sample vial via a pressurization step. The loop is connected to two 3-port solenoid valves. These valves allow for the sample volume to be swept to the concentrator for analysis and allow for cleanup of the loop between samples via hot water rinsing and an inert gas sweep.​
  • 84-Position Sample Tray – The 84-position sample tray loads quickly and is fully insulated, ensuring that chilled samples remain cool.​
  • Vial Chiller Tray – The vial chiller allows for sample cooling. The chiller requires the use of an external recirculating cooling bath (optional accessory) for operation.​
  • Valve Manifold – A precision-machined manifold reduces plumbing connections by 60% over previous designs and results in improved system reliability.
  • Hot Water Rinsing – The entire liquid pathway can be rinsed using the high temperature Deionized (DI) water cleaning technique which uses two internal reservoirs to heat blank water to 90 °C for rinsing.​
  • XYZ Automation – The quick, whisper-quiet arm has undergone years of refinement and testing to eliminate the issues typically associated with older XYZ autosampler platforms.​
  • Stackable Configuration – Stackable configuration minimizes the instrument footprint and saves lab bench space.​
  • Internal Standards – ​Internal standards/surrogates are stored in two 15 mL amber glass vessels to prevent transmission of UV radiation. Vessels are sealed with a PEEK™ cap to prevent adsorption and contamination of the standard solution.  Each standard vessel can deliver volumes of 1, 2, 5, 10, or 20 μL to each sample. Each standard injection valve can be used independently or in combination.​
  • Barcode – The AQUATek LVA has the ability to connect to a standard barcode reader in order to scan vial barcodes and automatically have the vial ID number added into the TekLink™ schedule.​
  • Blanking Water Reservoir – Reservoir included with system provides cleanup water and auto-blanking, which frees up vial space in the sample tray for increased throughput.​​

Related Products

The device features an easy-to-read color touch panel and one-handed precision dispensing for manual titration, with three dripping methods: Touch Panel Start, remote switch, and INCREMENT knob for mi
The device features an easy-to-read color touch panel and one-handed precision dispensing for manual titration, with three dripping methods: Touch Panel Start, remote switch, and INCREMENT knob for mi
Handheld water quality meters that measure pH, conductivity, resistivity, salinity, TDS and DO. Waterproof, dust proof, eco-friendly, shock and scratch resistant and built for hands-free testing.
Handheld water quality meters that measure pH, conductivity, resistivity, salinity, TDS and DO. Waterproof, dust proof, eco-friendly, shock and scratch resistant and built for hands-free testing.
With the highest level for 3D fluorescence spectra, F-7100 can be used in a wide range of applications from the cutting edge research to quality control.​
With the highest level for 3D fluorescence spectra, F-7100 can be used in a wide range of applications from the cutting edge research to quality control.​
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
Three analyzers in a single compact body deliver high-sensitivity, high-accuracy analysis of each measurement parameter.
Three analyzers in a single compact body deliver high-sensitivity, high-accuracy analysis of each measurement parameter.
Uses a tubular electric resistance heating furnace, offers highly accurate and sensitive analysis
Uses a tubular electric resistance heating furnace, offers highly accurate and sensitive analysis
Offers trapping benefits that have never been seen before by Purge and Trap concentrators.
Offers trapping benefits that have never been seen before by Purge and Trap concentrators.
STA (simultaneous thermogravimetric analysis) measures DSC and TGA simultaneously in a single unit.
STA (simultaneous thermogravimetric analysis) measures DSC and TGA simultaneously in a single unit.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

AQUATek LVA
VOC
AQUATek LVA
VOC