Your high-precision solution for diverse samples and increased productivity

The EMIA-Pro Carbon/Sulfur Analyzer provides exceptional accuracy, streamlined maintenance and user-friendly software enhancements that enable efficient measurements. Its reduced cycle time also helps to accelerate development and manufacturing speed.

Features

Greater Accuracy

Proven NDIR Gas Detection Technology

The EMIA-Pro Carbon/Sulfur Analyzer utilizes the infrared method to measure the carbon and sulfur content of a sample after combustion in an induction furnace. It leverages HORIBA’s reliable Non-Dispersive Infrared (NDIR) measurement technology, providing a measurement range optimized for carbon from 1.6 ppm to 6.0% and for sulfur from 2 ppm to 1.0%. The analyzer features a unique CO detector and can be utilized for a wide range of inorganic materials, including steel, cokes, catalysts, non-ferrous alloys like aluminum, and lithium-ion battery materials.

Please also refer the Measurement Principle page for the details.

 

Flexible Upgrade after Installation

Customer has the option to expand the functionality of the EMIA-Pro system at any time, even after installation, depending on their specific needs:

  • Purifier Unit for carrier gas (for C Analysis) – Enables measurement of ultra-low carbon concentration with high accuracy by eliminating hydrocarbon impurities in the carrier gas.
  • Auto Sampler Unit – Able to accommodate up to 20 positions.
  • Halogen Trap Unit – Helps remove halogen elements in the sample to prevent damage to the device.

 


 

Improved Measurement and Maintenance Efficiency

Substantial Reduction in Maintenance

Along with the EMIA-Pro’s cleaning feature, HORIBA has developed a robust design with fewer components for more reliable use and less service requirements.

 

The latest innovations have enabled the cleaning time for the EMIA Series to be typically half that of our conventional models (patent applied for*). Additionally, the structure around the combustion area has been designed to be as simple as possible, allowing for quick and intuitive maintenance. Specialized skills or knowledge are not required for maintenance work.

Flat design around the crucible stand    

 

The cleaning efficiency of the EMIA Series instruments has been significantly improved compared to our conventional Carbon/Sulfur analyzers with the use of a unique automatic cleaning mechanism (patent applied for*). This allows users to repeat measurements up to 200 times**, with reduced time required for maintenance and cleaning, without sacrificing measurement accuracy.

* JP6063582, US10379017, EP3064938, ZL201480058824.2, IN351227, JP6605807, US9778148, EP3037814 and ZL201510971175.1
** Number of repeatable measurements may vary depending on the sample and measurement conditions.

 

Before measurement               After 200 measurements

 

High Throughput

The EMIA Series can complete one measurement cycle, measurement-display result-cleaning, in 70 seconds (i.e. about 50 samples/hour).

 


More Intuitive Software for Easy Operation

Advanced Operation Software

The EMIA Series features its own proprietary operating software, which has been designed with a focus on ease of use, optimizing layout, operating menus, and functions for enhanced user-friendliness.

 

Enhanced Operator Assistance

Additionally, the software includes a self-diagnostic monitoring feature to assess the status of connected devices, an alarm function, and three navigators to recommend the most suitable conditions for samples, troubleshoot errors, and alert users to perform maintenance. These features improve daily operation and ensure efficient analysis.

Related Products

The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
The UH5300 is controllable through a tablet terminal (iPad or Windows 10) offering new levels of access, control, and operation.
The QuickTrace® M-8000 Cold Vapor Atomic Fluorescence (CVAF) Mercury Analyzer​ is ideal for ultra-trace to sub-mg/L mercury quantitation.
The Lotix Combustion TOC analyzer is designed to accurately measure carbon content in aqueous matrices down to the ppb level.
The Iridia Laser Ablation System​ is a purpose-built laser ablation system designed for ultimate flexibility and capable of addressing an increasing range of demanding applications.
The EMIA-Pro Carbon/Sulfur Analyzer provides exceptional accuracy, streamlined maintenance and user-friendly software enhancements that enable efficient measurements.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
​​​​​​​​The Analyte HE Laser Ablation System​​ offers excimer technology at 193 nm with all the analytical capabilities you require, delivering finely controlled, “homogenized-flat” ablations.
The LA-960 combines the most popular modern sizing technique with state of the art refinements to measure wet and dry samples measuring 10 nanometers to 5 millimeters.
Intuitive and very easy to use touch panel operation. Easy to clean glass top and round body. Horiba LAQUA Benchtop Type Water Quality Meter is both easy and fun to use!

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

EMIA-PRO
Carbon and Sulfur Analyzer
EMIA-PRO