Your high-precision solution for diverse samples and increased productivity

The EMIA-Pro Carbon/Sulfur Analyzer provides exceptional accuracy, streamlined maintenance and user-friendly software enhancements that enable efficient measurements. Its reduced cycle time also helps to accelerate development and manufacturing speed.

Features

Greater Accuracy

Proven NDIR Gas Detection Technology

The EMIA-Pro Carbon/Sulfur Analyzer utilizes the infrared method to measure the carbon and sulfur content of a sample after combustion in an induction furnace. It leverages HORIBA’s reliable Non-Dispersive Infrared (NDIR) measurement technology, providing a measurement range optimized for carbon from 1.6 ppm to 6.0% and for sulfur from 2 ppm to 1.0%. The analyzer features a unique CO detector and can be utilized for a wide range of inorganic materials, including steel, cokes, catalysts, non-ferrous alloys like aluminum, and lithium-ion battery materials.

Please also refer the Measurement Principle page for the details.

 

Flexible Upgrade after Installation

Customer has the option to expand the functionality of the EMIA-Pro system at any time, even after installation, depending on their specific needs:

  • Purifier Unit for carrier gas (for C Analysis) – Enables measurement of ultra-low carbon concentration with high accuracy by eliminating hydrocarbon impurities in the carrier gas.
  • Auto Sampler Unit – Able to accommodate up to 20 positions.
  • Halogen Trap Unit – Helps remove halogen elements in the sample to prevent damage to the device.

 


 

Improved Measurement and Maintenance Efficiency

Substantial Reduction in Maintenance

Along with the EMIA-Pro’s cleaning feature, HORIBA has developed a robust design with fewer components for more reliable use and less service requirements.

 

The latest innovations have enabled the cleaning time for the EMIA Series to be typically half that of our conventional models (patent applied for*). Additionally, the structure around the combustion area has been designed to be as simple as possible, allowing for quick and intuitive maintenance. Specialized skills or knowledge are not required for maintenance work.

Flat design around the crucible stand    

 

The cleaning efficiency of the EMIA Series instruments has been significantly improved compared to our conventional Carbon/Sulfur analyzers with the use of a unique automatic cleaning mechanism (patent applied for*). This allows users to repeat measurements up to 200 times**, with reduced time required for maintenance and cleaning, without sacrificing measurement accuracy.

* JP6063582, US10379017, EP3064938, ZL201480058824.2, IN351227, JP6605807, US9778148, EP3037814 and ZL201510971175.1
** Number of repeatable measurements may vary depending on the sample and measurement conditions.

 

Before measurement               After 200 measurements

 

High Throughput

The EMIA Series can complete one measurement cycle, measurement-display result-cleaning, in 70 seconds (i.e. about 50 samples/hour).

 


More Intuitive Software for Easy Operation

Advanced Operation Software

The EMIA Series features its own proprietary operating software, which has been designed with a focus on ease of use, optimizing layout, operating menus, and functions for enhanced user-friendliness.

 

Enhanced Operator Assistance

Additionally, the software includes a self-diagnostic monitoring feature to assess the status of connected devices, an alarm function, and three navigators to recommend the most suitable conditions for samples, troubleshoot errors, and alert users to perform maintenance. These features improve daily operation and ensure efficient analysis.

Related Products

The Volumetric Karl Fischer Titrator features a 8.4-inch LCD touch panel, adjustable display, USB data management, built-in printer, and supports simultaneous measurement of up to 4 moisture types.
The Torch is considered the premium TOC combustion analyzer due to its many useful features and automated analysis processes. 
The Fusion TOC Analyzer offers more flexibility, intelligence and user friendliness making this analyzer ideally suited for the most demanding laboratory needs.
The AminoSAAYA offers easy and comfortable operability while maintaining the reliability and stability of Hitachi’ s legacy amino acid analyzers.
The LA-960 combines the most popular modern sizing technique with state of the art refinements to measure wet and dry samples measuring 10 nanometers to 5 millimeters.
The ASX-560 four-rack autosampler is a compact and efficient solution for medium- to high-volume sample applications, capable of holding up to 360 samples.
The Iridia Laser Ablation System​ is a purpose-built laser ablation system designed for ultimate flexibility and capable of addressing an increasing range of demanding applications.
HORIBA MESA-50 Series is a portable benchtop energy dispersive X-ray fluorescence (EDXRF) analyzer with ultimate user-friendly operation.
Intuitive and very easy to use touch panel operation. Easy to clean glass top and round body. Horiba LAQUA Benchtop Type Water Quality Meter is both easy and fun to use!
Vaporizers efficiently measure moisture in solid and powdered samples, including resin pellets, medicines, inorganic powders, granules, and copy machine toner.

How can we help?

You may contact our specialists by accomplishing form below.

Website menu

Download catalog

To download e-catalog, please submit your details below.

Hamamatsu Failure Analysis

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire About this Product

You may contact our specialists by accomplishing form below.

EMIA-PRO
Carbon and Sulfur Analyzer
EMIA-PRO
Carbon and Sulfur Analyzer