Data Logger

Temp/RH/Light/Ext-Analog Data Logger

Measures and transmits temperature, relative humidity, and light intensity data wirelessly. Includes an external analog input to attach a variety of additional sensors.

Overview

Measures and transmits temperature, relative humidity, and light intensity data wirelessly. Includes an external analog input to attach a variety of additional sensors.

This self-contained, Bluetooth-enabled, wireless data logger lets you use your mobile device or Windows computer and Onset’s free HOBOconnect app to access data, at any time, when within 100 feet of the logger. Configure the logger, read out data, view data in graphs, check the operational status of loggers, configure alarm notifications, and share data files – with no dedicated equipment beyond a mobile device or laptop.

Purchase an MX Data Plan to get more out of your data and access it from anywhere using the LI-COR Cloud software platform (formerly HOBOlink)! You can also purchase the MX Gateway station, which automatically sends your logger’s data to LI-COR Cloud.

Features
  • Bluetooth communication for wireless data offload
  • 16-bit resolution for highly-accurate measurements
  • Stores 1.9 million measurements for longer deployments between offloads
  • New Self-Describing sensors with automatic configuration for fast deployment
  • Compatible with existing sensors for a wide range of indoor monitoring
  • Audible and visual LCD-screen alarms notify you if sensor becomes unplugged or a reading exceeds set thresholds
Specifications

Temperature Sensor (MX1104)

Range

-20° to 70°C
-4° to 158°F

Accuracy

±0.20°C from 0° to 50°C
±0.36°F from 32° to 122°F

Resolution

0.002°C at 25°C
0.004°F at 77°F

Drift

<0.1°C (0.18°F) per year

RH Sensor* (MX1104)

Range

0% to 100% at -20° to 70°C (-4° to 158°F); exposure to conditions above 95% may temporarily increase the maximum RH sensor error by an additional 1%

Accuracy

±2.5% from 10% to 90% (typical) to a maximum of ±3.5% including hysteresis at 25°C (77°F); below 10% and above 90% ±5% typical

Resolution

0.01%

Drift

<1% per year typical

Response Time (MX1104)

Temperature

11 minutes in air moving 1 m/s (2.2 mph)

RH

30 seconds to 90% in airflow of 1 m/s (2.2 mph)

Light Sensor (M1104)

Range

0 to 167,731 lux
15,582 lum/ft2

Accuracy

±10% typical for direct sunlight (see Light Measurement on page 4 for more details)

Logger with
Cable Type
SD-MA-420 or CABLE-4-20mASD-VOLT-2.5 or CABLE-2.5-STEREOSD-VOLT-05 or CABLE-
ADAP5
SD-VOLT-10 or CABLE-ADAP10SD-VOLT-24 or CABLE-ADAP24
Measurement Range0 to 20.1 mA0 to 2.5 V0 to 5.0 V0 to 10 V0 to 24 V
Accuracy±0.001 mA ±0.2% of reading±0.1 mV ±0.1% of reading±0.2 mV ±0.3% of reading±0.4 mV ±0.3% of reading±1.0 mV ±0.3% of reading
Resolution0.3 µA40 µV80 µV160 µV384 µV

Logger

Operating Range

-20° to 70°C
-4° to 158°F

Radio Power

1 mW

0 dBm

Transmission Range

Approximately 30.5 m (100 ft) line-of-sight

Wireless Data Standard

Bluetooth Low Energy (Bluetooth Smart)

Logging Rate

1 second to 18 hours

Logging Modes

Fixed interval (normal, statistics) or burst

Memory Modes

Wrap when full or stop when full

Start Modes

Immediate, push button, date & time, or next interval

Stop Modes

When memory full, push button, date & time, or after a set logging period

Restart Mode

Push button

Time Accuracy

±1 minute per month at 25°C

77°F

Battery Type

Two AAA 1.5 V alkaline batteries, user replaceable

Battery Life

1 year, typical with logging interval of 1 minute and Bluetooth Always On enabled; 2 years, typical with logging interval of 1 minute and Bluetooth Always On disabled; and temperatures between 0° and 50°C (32° and 122°F). Faster logging intervals and statistics sampling intervals, burst logging, remaining connected with the app, excessive downloads, and paging may impact battery life.

Memory

4 MB (1.9 million measurements, maximum)

Full Memory Download Time

Approximately 4 to 15 minutes depending on the mobile device; may take longer the further the device is from the logger

LCD

LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range

Size

11.28 x 5.41 x 2.92 cm
4.44 x 2.13 x 1.15 in.

Weight

123 g
4.34 oz

Environmental Rating

IP54

For more informationcontact us.

Choose manual language:

Choose quick start language:

Features

Choose manual language:

Choose quick start language:

Related Products

The LI-7500DS is designed for high-speed CO2 and water vapor measurements in ambient air. Lower power and maintenance requirements make it ideal for field deployments.
LI-COR eddy covariance systems measure the exchange of CO2, H2O, CH4 , and energy between the earth’s surface and the atmosphere, empowering researchers to advance scientific understanding of climate
The 8200-104 Opaque Long-Term Chamber accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.
The LI-8250 acts as a single point of access to interact with and control a LI-COR gas analyzer and up to 36 chambers or flasks.
The 8200-01S Smart Chamber is a portable, self-powered 20 cm survey chamber used to assess the spatial variability of soil gas fluxes.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

Temp/RH/Light/Ext-Analog Data Logger
Data Logger
Temp/RH/Light/Ext-Analog Data Logger
Data Logger