MICAP-OES 1000 Plasma Source

Unique Design
Unique Performance

Optical Emission Spectrometer
Echelle spectrometer simultaneously measures the entire wavelength range with every solution injection.

Wavelength range: 194 nm – 625 nm + 766 nm

Resolution 5pm – 30 pm, 7 pm at 200 nm

Annual CO2e Emissions Savings Compared to Argon Carbon Footprint

Unique Design
Unique Performance

Optical Emission Spectrometer
Echelle spectrometer simultaneously measures the entire wavelength range with every solution injection.

Wavelength range: 194 nm – 625 nm + 766 nm

Resolution 5pm – 30 pm, 7 pm at 200 nm

Annual CO2e Emissions Savings Compared to Argon Carbon Footprint

MICAP OES 1000 Plasma Source

Product Specification

Variable speed four-channel peristaltic pump and concentric 1 mL/min nebulizer are standard sample introduction assembly (SIA) components.

Vertical torch position with axial viewing and automated, uniform plasma tail removal.

Echelle Spectrometer simultaneously measures the entire wavelength range with every solution injection.

Power requirements:

  • Mains power: 208 V to 240 V/10 A
  • No water cooling required

Exhaust:

  • 4 inch (100 mm) exhaust with flow rate between 100 – 200 cfm (1.5 – 2.9 m/s)

Gas flows:

  • Mass flow controlled coolant, auxillary and nebulizer gas for reliable and stable sample measurement
  • Typical plasma gas flow is 14L/min
  • Nitrogen gas can be sourced from liquid dewar, compressed gas cylinder or nitrogen generator

Size:

  • [W] 20.7 in (525 mm) x [H] 22 in (560 mm) x [D] 14 in (350 mm)

Weight:

  • MICAP Plasma Source Unit 42 lbs (19 kg)
  • Total weight of MICAP with Spectrometer 67 lbs (30 kg)

Camera

Detector

  • sCMOS

Array diagonal:

  • 31 mm

Resolution:

  • 2048 x 2048

Cooling:

  • Peltier cooled to -10 °C

Other parameters:

  • Pixel size: 11 µm x 11 µm
  • Frame rate: 24 fps

Optical Emission Spectrometer of OES 1000 Plasma Source

Wavelength range:

  • Simultaneous measurement 194 nm – 625 nm + 766 nm

Slit Width:

  • 30 um slit

Resolution:

  • 5pm – 30 pm, 7 pm at 200 nm

Operating environment:

  • Temperature: 20 – 25 °C (68 – 77 °F)
  • Relative Humidity: 20-60 %

Key Design Features

  • Simplified architecture with Methods for conditions and Sessions for running samples
  • Detailed peak viewing with quick peak integration settings
  • Spectral database to highlight potential spectral overlaps
  • Live time scan for sample introduction optimization

Key Performance Features

  • AI-powered spectral processing
  • Continuous Nitrogen background correction
  • Simultaneous data capture allows application of internal standardization in high matrix samples
  • Full spectrum capture provides alternate line addition
  • Delivers full analysis flexibility post-acquisition

OES 1000 Plasma Source

OES 1000 Plasma Source

For more informationcontact us.

Click here.

Application Note: Lubricant Oil Analysis for Wear Metals, Additives, and Ingress Elements

Application Note – MICAP OES Lubricant Oil

Related Products

The Fusion TOC Analyzer offers more flexibility, intelligence and user friendliness making this analyzer ideally suited for the most demanding laboratory needs.
The Fusion TOC Analyzer offers more flexibility, intelligence and user friendliness making this analyzer ideally suited for the most demanding laboratory needs.
The UH5300 is controllable through a tablet terminal (iPad or Windows 10) offering new levels of access, control, and operation.
The UH5300 is controllable through a tablet terminal (iPad or Windows 10) offering new levels of access, control, and operation.
Optimise sample preparation with SimPrep. Perform dilutions, dosing, and standard additions with precision, staying within 1% of the target volume.
Optimise sample preparation with SimPrep. Perform dilutions, dosing, and standard additions with precision, staying within 1% of the target volume.
The Teledyne Tekmar U-shaped trap offers trapping benefits that have never been seen before by Purge and Trap concentrators.
The Teledyne Tekmar U-shaped trap offers trapping benefits that have never been seen before by Purge and Trap concentrators.
Autotouch Hydraulic Presses are available in 8 Ton, 15 Ton, 25 Ton and 40 Ton load configurations.
Autotouch Hydraulic Presses are available in 8 Ton, 15 Ton, 25 Ton and 40 Ton load configurations.
Next evolution of micro-X-ray fluorescence spectroscopy ultimate performance in speed and flexibility
Next evolution of micro-X-ray fluorescence spectroscopy ultimate performance in speed and flexibility
A high‑performance benchtop FTIR, the IR5 is ideal for everyday analysis, delivering fast and accurate IR measurements.
A high‑performance benchtop FTIR, the IR5 is ideal for everyday analysis, delivering fast and accurate IR measurements.
The AminoSAAYA offers easy and comfortable operability while maintaining the reliability and stability of Hitachi’ s legacy amino acid analyzers.
The AminoSAAYA offers easy and comfortable operability while maintaining the reliability and stability of Hitachi’ s legacy amino acid analyzers.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

MICAP-OES 1000 Plasma Source
MICAP-OES 1000 Plasma Source