Simultaneous Thermogravimetric Analyzer (DSC-TGA)

NEXTA STA Series

The newly incorporated balance control technology ensures the microgram-level baseline stability and reproducibility on top of our highly acclaimed horizontal digital dual beam balance system. The NEXTA STA series has following features;
High temperature control technology that handles a variety of temperature programs
Available DSC measurement, it makes specific heat capacity measurements available
The sample observation and measurement, Hitachi’s pioneering key feature
Includes the newly designed flow channels for high-level gas exchange

In addition to conventional applications, the NEXTA STA series shows its strength in analyses such as quantitative determination of the constituents of advanced materials, composite materials, and trace amounts of moisture.

Key Industries: Batteries, Cement and Limestone, Ceramics, Chemicals, Food and Beverage, Lenses, Mining, Pharmaceutical, Polymers, Semiconductor and Electronics and more.


Features

1. World class baseline performance

The NEXTA STA series incorporates a new balance control technology in addition to the horizontal digital dual beam system that has been well received in our previous models. Conventionally, baseline drift occurs due to hysteresis in the temperature program or surrounding environmental factors. However, by incorporating a new balance technology, the NEXTA STA series achieved baseline stability that is not affected by the temperature program.

Digital horizontal differential system

2. Broad measurement application using high temperature control technology

The NEXTA STA series heating furnace has the improved temperature control technology which realizes several temperature programs, such as heating at a constant heating rate, repetition heating and cooling, heating up and hold isothermal, temperature modulated DSC, and controlled reaction rate thermal analysis.

-

3. Available DSC measurement on the NEXTA STA series – Specific heat capacity measurement over the wide temperature range achieved by DSC

The NEXTA STA series showcases an evolution from DTA to DSC, enabling simultaneous thermogravimetry and DSC measurement, which defines it from its predecessors. In addition, by using temperature modulated DSC, specific heat capacity measurements are achieved over a wide temperature range that cannot be measured by (the) standalone DSC.

-
-

4. “Real View®” Sample Observation Option

The well-received “Real View®” option has been further developed.
Not only are samples observed while measurements are in progress, but various analysis features have been incorporated, such as digital zoom, image analysis, length measurement capability, and color analysis, which can support a variety of applications.

-

*“Real View” is a registered trademark of Hitachi High-Tech Science Corporation in the U.S, Brazil, China, India, Turkey, the European Union, and Japan.

Specifications

 STA200STA200RVSTA300
Balance TypeHorizontal Differential Type
Temperature RangeAmbient to 1,100°CAmbient to 1,000°CAmbient to 1,500°C
TG Baseline drift 1)<10 ug
TG Baseline Stability 2)<10 ug
DSC FunctionStandardly equipped
Specific Heat Capacity MeasurementAvailable (Optional)
Temperature Precision+/-0.07°C
Temperature Accuracy+/-0.2°C
Real View®N/AOptionalN/A
Gas ControlIntegrated Mass Flow controller

1)Amount of Baseline drift at heating up to 1000°C with 20°C/min

2)Amount of baseline drift at 1000°C hold in 60min

Hitachi NEXTA STA Simultaneous thermogravimetric analyzer

The Hitachi NEXTA STA Simultaneous thermogravimetric analyzer) measures DSC and TGA simultaneously in a single unit. Available for Philippine market through Sigmatech Inc.

Video

 

The Hitachi NEXTA STA Simultaneous thermogravimetric analyzer) measures DSC and TGA simultaneously in a single unit. Available for Philippines through Sigmatech Inc.
Features

Features

1. World class baseline performance

The NEXTA STA series incorporates a new balance control technology in addition to the horizontal digital dual beam system that has been well received in our previous models. Conventionally, baseline drift occurs due to hysteresis in the temperature program or surrounding environmental factors. However, by incorporating a new balance technology, the NEXTA STA series achieved baseline stability that is not affected by the temperature program.

Digital horizontal differential system

2. Broad measurement application using high temperature control technology

The NEXTA STA series heating furnace has the improved temperature control technology which realizes several temperature programs, such as heating at a constant heating rate, repetition heating and cooling, heating up and hold isothermal, temperature modulated DSC, and controlled reaction rate thermal analysis.

-

3. Available DSC measurement on the NEXTA STA series – Specific heat capacity measurement over the wide temperature range achieved by DSC

The NEXTA STA series showcases an evolution from DTA to DSC, enabling simultaneous thermogravimetry and DSC measurement, which defines it from its predecessors. In addition, by using temperature modulated DSC, specific heat capacity measurements are achieved over a wide temperature range that cannot be measured by (the) standalone DSC.

-
-

4. “Real View®” Sample Observation Option

The well-received “Real View®” option has been further developed.
Not only are samples observed while measurements are in progress, but various analysis features have been incorporated, such as digital zoom, image analysis, length measurement capability, and color analysis, which can support a variety of applications.

-

*“Real View” is a registered trademark of Hitachi High-Tech Science Corporation in the U.S, Brazil, China, India, Turkey, the European Union, and Japan.

Specifications

  STA200 STA200RV STA300
Balance Type Horizontal Differential Type
Temperature Range Ambient to 1,100°C Ambient to 1,000°C Ambient to 1,500°C
TG Baseline drift 1) <10 ug
TG Baseline Stability 2) <10 ug
DSC Function Standardly equipped
Specific Heat Capacity Measurement Available (Optional)
Temperature Precision +/-0.07°C
Temperature Accuracy +/-0.2°C
Real View® N/A Optional N/A
Gas Control Integrated Mass Flow controller

1)Amount of Baseline drift at heating up to 1000°C with 20°C/min

2)Amount of baseline drift at 1000°C hold in 60min

Video

 

The Hitachi NEXTA STA Simultaneous thermogravimetric analyzer) measures DSC and TGA simultaneously in a single unit. Available for Philippines through Sigmatech Inc.

Related Products

Optimise sample preparation with SimPrep. Perform dilutions, dosing, and standard additions with precision, staying within 1% of the target volume.
The Volumetric Karl Fischer Titrator features a 8.4-inch LCD touch panel, adjustable display, USB data management, built-in printer, and supports simultaneous measurement of up to 4 moisture types.
The LA-960 combines the most popular modern sizing technique with state of the art refinements to measure wet and dry samples measuring 10 nanometers to 5 millimeters.
The AminoSAAYA offers easy and comfortable operability while maintaining the reliability and stability of Hitachi’ s legacy amino acid analyzers.

VOC

The AQUATek LVA automates VOC water analysis, ensuring USEPA compliance and easy maintenance.
Ethos offers powerful solutions integrated into a single platform including low-acceleration Ar/Xe ion-beam processing when configured as a Triple-Beam system.
The Insight-Scan (IS) series of Scanning Acoustic Microscopes(SAM) integrates the finest state-of-the-art technology for high resolution, high speed, fully digital non-destructive sample analysis.
The AFM100 Series is Hitachi’s next generation probe microscopy platform.
The UH5300 is controllable through a tablet terminal (iPad or Windows 10) offering new levels of access, control, and operation.
Hitachi’s DMA is the perfect tool for assessing both stiff and soft samples, while also capturing rapid modulus changes.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

NEXTA STA Series
Simultaneous Thermogravimetric Analyzer (DSC-TGA)
NEXTA STA Series
Simultaneous Thermogravimetric Analyzer (DSC-TGA)