Simultaneous Thermogravimetric Analyzer (DSC-TGA)

NEXTA STA Series

The newly incorporated balance control technology ensures the microgram-level baseline stability and reproducibility on top of our highly acclaimed horizontal digital dual beam balance system. The NEXTA STA series has following features;
High temperature control technology that handles a variety of temperature programs
Available DSC measurement, it makes specific heat capacity measurements available
The sample observation and measurement, Hitachi’s pioneering key feature
Includes the newly designed flow channels for high-level gas exchange

In addition to conventional applications, the NEXTA STA series shows its strength in analyses such as quantitative determination of the constituents of advanced materials, composite materials, and trace amounts of moisture.

Key Industries: Batteries, Cement and Limestone, Ceramics, Chemicals, Food and Beverage, Lenses, Mining, Pharmaceutical, Polymers, Semiconductor and Electronics and more.


Features

1. World class baseline performance

The NEXTA STA series incorporates a new balance control technology in addition to the horizontal digital dual beam system that has been well received in our previous models. Conventionally, baseline drift occurs due to hysteresis in the temperature program or surrounding environmental factors. However, by incorporating a new balance technology, the NEXTA STA series achieved baseline stability that is not affected by the temperature program.

Digital horizontal differential system

2. Broad measurement application using high temperature control technology

The NEXTA STA series heating furnace has the improved temperature control technology which realizes several temperature programs, such as heating at a constant heating rate, repetition heating and cooling, heating up and hold isothermal, temperature modulated DSC, and controlled reaction rate thermal analysis.

-

3. Available DSC measurement on the NEXTA STA series – Specific heat capacity measurement over the wide temperature range achieved by DSC

The NEXTA STA series showcases an evolution from DTA to DSC, enabling simultaneous thermogravimetry and DSC measurement, which defines it from its predecessors. In addition, by using temperature modulated DSC, specific heat capacity measurements are achieved over a wide temperature range that cannot be measured by (the) standalone DSC.

-
-

4. “Real View®” Sample Observation Option

The well-received “Real View®” option has been further developed.
Not only are samples observed while measurements are in progress, but various analysis features have been incorporated, such as digital zoom, image analysis, length measurement capability, and color analysis, which can support a variety of applications.

-

*“Real View” is a registered trademark of Hitachi High-Tech Science Corporation in the U.S, Brazil, China, India, Turkey, the European Union, and Japan.

Specifications

 STA200STA200RVSTA300
Balance TypeHorizontal Differential Type
Temperature RangeAmbient to 1,100°CAmbient to 1,000°CAmbient to 1,500°C
TG Baseline drift 1)<10 ug
TG Baseline Stability 2)<10 ug
DSC FunctionStandardly equipped
Specific Heat Capacity MeasurementAvailable (Optional)
Temperature Precision+/-0.07°C
Temperature Accuracy+/-0.2°C
Real View®N/AOptionalN/A
Gas ControlIntegrated Mass Flow controller

1)Amount of Baseline drift at heating up to 1000°C with 20°C/min

2)Amount of baseline drift at 1000°C hold in 60min

Hitachi NEXTA STA Simultaneous thermogravimetric analyzer

The Hitachi NEXTA STA Simultaneous thermogravimetric analyzer) measures DSC and TGA simultaneously in a single unit. Available for Philippine market through Sigmatech Inc.

Video

 

The Hitachi NEXTA STA Simultaneous thermogravimetric analyzer) measures DSC and TGA simultaneously in a single unit. Available for Philippines through Sigmatech Inc.

Hitachi NEXTA STA Simultaneous thermogravimetric analyzer

Features

Features

1. World class baseline performance

The NEXTA STA series incorporates a new balance control technology in addition to the horizontal digital dual beam system that has been well received in our previous models. Conventionally, baseline drift occurs due to hysteresis in the temperature program or surrounding environmental factors. However, by incorporating a new balance technology, the NEXTA STA series achieved baseline stability that is not affected by the temperature program.

Digital horizontal differential system

2. Broad measurement application using high temperature control technology

The NEXTA STA series heating furnace has the improved temperature control technology which realizes several temperature programs, such as heating at a constant heating rate, repetition heating and cooling, heating up and hold isothermal, temperature modulated DSC, and controlled reaction rate thermal analysis.

-

3. Available DSC measurement on the NEXTA STA series – Specific heat capacity measurement over the wide temperature range achieved by DSC

The NEXTA STA series showcases an evolution from DTA to DSC, enabling simultaneous thermogravimetry and DSC measurement, which defines it from its predecessors. In addition, by using temperature modulated DSC, specific heat capacity measurements are achieved over a wide temperature range that cannot be measured by (the) standalone DSC.

-
-

4. “Real View®” Sample Observation Option

The well-received “Real View®” option has been further developed.
Not only are samples observed while measurements are in progress, but various analysis features have been incorporated, such as digital zoom, image analysis, length measurement capability, and color analysis, which can support a variety of applications.

-

*“Real View” is a registered trademark of Hitachi High-Tech Science Corporation in the U.S, Brazil, China, India, Turkey, the European Union, and Japan.

Specifications

  STA200 STA200RV STA300
Balance Type Horizontal Differential Type
Temperature Range Ambient to 1,100°C Ambient to 1,000°C Ambient to 1,500°C
TG Baseline drift 1) <10 ug
TG Baseline Stability 2) <10 ug
DSC Function Standardly equipped
Specific Heat Capacity Measurement Available (Optional)
Temperature Precision +/-0.07°C
Temperature Accuracy +/-0.2°C
Real View® N/A Optional N/A
Gas Control Integrated Mass Flow controller

1)Amount of Baseline drift at heating up to 1000°C with 20°C/min

2)Amount of baseline drift at 1000°C hold in 60min

Video

 

The Hitachi NEXTA STA Simultaneous thermogravimetric analyzer) measures DSC and TGA simultaneously in a single unit. Available for Philippines through Sigmatech Inc.

Hitachi NEXTA STA Simultaneous thermogravimetric analyzer

Related Products

The Excite Pharos is a compact, user-friendly femtosecond laser ablation system with a fully sealed, factory-aligned laser head requiring no routine adjustments or cleaning.
With the highest level for 3D fluorescence spectra, F-7100 can be used in a wide range of applications from the cutting edge research to quality control.​
With options for both oxidizing and non-oxidizing metals, as well as carbon evaporation, Quorum coaters are suitable for applications, including high-resolution SEM and FIB-SEM, ensuring precise resu
The LA-960 combines the most popular modern sizing technique with state of the art refinements to measure wet and dry samples measuring 10 nanometers to 5 millimeters.
The Ratio Beam Spectrophotometer U-5100 delivers a compact, lightweight package with remarkable power savings and a long life for its light source.
The Fusion TOC Analyzer offers more flexibility, intelligence and user friendliness making this analyzer ideally suited for the most demanding laboratory needs.
The Coulometric Karl Fischer Titrator offers an 8.4-inch touch LCD, adjustable display angles, USB data management, a thermal printer, and simultaneous measurement of up to 4 moisture types.
Handheld water quality meters that measure pH, conductivity, resistivity, salinity, TDS and DO. Waterproof, dust proof, eco-friendly, shock and scratch resistant and built for hands-free testing.
The PHEMOS-X is a high-resolution emission microscope that pinpoints failure locations in semiconductor devices by detecting the weak light emissions and heat emissions caused by defects.
In combination with very sensitive detector technology, especially the fluorescence detector, the Chromaster HPLC system is one of the strongest LC systems on the market.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

NEXTA STA Series
Simultaneous Thermogravimetric Analyzer (DSC-TGA)
NEXTA STA Series
Simultaneous Thermogravimetric Analyzer (DSC-TGA)