Opaque Long-Term Chamber

8200-104

The 8200-104 Opaque Long-Term Chamber builds on the trusted and patented technology from the previous generation. This line of long-term chambers withstands the elements with improvements to the design. The 8200-104 accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.

A motorized chamber finished in durable and reflective white enamel rotates away from your soil collar. This allows the soil in the collar to see natural environmental conditions when a measurement is not taking place. The chamber may be left unattended for extended periods of time to make automated measurements, with low power draw (7.5W maximum when opening or closing).

The 8200-104 Opaque Long-Term Chamber builds on the trusted and patented technology from the previous generation. This line of long-term chambers withstands the elements with improvements to the design. The 8200-104 accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.

A motorized chamber finished in durable and reflective white enamel rotates away from your soil collar. This allows the soil in the collar to see natural environmental conditions when a measurement is not taking place. The chamber may be left unattended for extended periods of time to make automated measurements, with low power draw (7.5W maximum when opening or closing).

How are LI-COR chambers different?

The 8200-104 Opaque Long-Term Chamber and all LI-COR chambers have been carefully and intentionally designed to minimize their impact on the natural soil activity with consideration toward:

  • Maintaining chamber pressure with ambient air.
  • Achieving air mixing without a fan.
  • Accounting for the impact of altered diffusion gradient on the flux.
  • Minimizing the impact of the chamber on your soil environment.

 Learn more about the science and engineering behind the 8200-104 Opaque Long-Term Chamber.

8200-104 Chamber

Specifications

  • Dimensions: 48.3 cm L × 38.1 cm W × 33.0 cm H
  • Weight: 7.3 kg
  • Chamber Volume: 4076.1 cm3
  • Soil Area Exposed: 317.8 cm2
  • Weatherproof Rating: Tested to IEC IP55 standard
  • Air Temperature Thermistor:
    • Operating Range: -20 to 50 °C
    • Accuracy: ±0.3 °C from -20 to 50 °C
  • Light Sensor Current Input:
    • Range: 0 to 100 µA
    • Resolution: 1.5 nA
    • Accuracy: ±(0.37 % of Reading + 8 nA) from -20 to 50 °C
  • SDI-12 Communications Interface:
    • Max Number of Devices: 10
    • Output Voltage: 12 VDC, 200 mA

Specifications subject to change without notice.

Brochure

8250-02 Calibration Manifold Insert

Soil Gas Flux Measurement Solutions

Field guide to instruments for the earth sciences

Related Products

LI-COR eddy covariance systems measure the exchange of CO2, H2O, CH4 , and energy between the earth’s surface and the atmosphere, empowering researchers to advance scientific understanding of climate
LI-COR eddy covariance systems measure the exchange of CO2, H2O, CH4 , and energy between the earth’s surface and the atmosphere, empowering researchers to advance scientific understanding of climate
The 8200-104C Clear Long-Term Chamber has been specially designed for NCE measurements. It includes technology and patents designed to minimize chamber impact on natural plant and soil activity with c
The 8200-104C Clear Long-Term Chamber has been specially designed for NCE measurements. It includes technology and patents designed to minimize chamber impact on natural plant and soil activity with c
The LI-192 Underwater Quantum Sensor measures PAR from all angles in one hemisphere. The LI-192 works in air or underwater at depths up to 560 meters.
The LI-192 Underwater Quantum Sensor measures PAR from all angles in one hemisphere. The LI-192 works in air or underwater at depths up to 560 meters.
The LI-3100C is a rugged bench-top instrument designed to quickly digitize the area, length, and width of leaves.
The LI-3100C is a rugged bench-top instrument designed to quickly digitize the area, length, and width of leaves.
The LI-7700 is designed specifically for eddy covariance flux measurements to evaluate methane emissions from the terrestrial landscape.
The LI-7700 is designed specifically for eddy covariance flux measurements to evaluate methane emissions from the terrestrial landscape.
The LI-870 delivers rapid CO2 flux measurements with great precision while being light enough (2.31 kg) to carry all day without wearing you out.
The LI-870 delivers rapid CO2 flux measurements with great precision while being light enough (2.31 kg) to carry all day without wearing you out.
Get rapid insights into stomatal conductance, chlorophyll fluorescence, and leaf angle for a variety of leaf sizes and morphologies, including many needles and narrow grasses.
Get rapid insights into stomatal conductance, chlorophyll fluorescence, and leaf angle for a variety of leaf sizes and morphologies, including many needles and narrow grasses.
Rugged and Bluetooth-enabled, the MX2308 delivers research-grade monitoring of key growing conditions—photosynthetically active radiation (PAR), temperature and relative humidity
Rugged and Bluetooth-enabled, the MX2308 delivers research-grade monitoring of key growing conditions—photosynthetically active radiation (PAR), temperature and relative humidity

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

8200-104
Opaque Long-Term Chamber
8200-104
Opaque Long-Term Chamber