More Accurate Whole Crude Oil Analysis Optimizes Product Value.

The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.

More Accurate Whole Crude Oil Analysis Optimizes Product Value.

The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.

PAC AC Crude Oil Analyzer Philippines

ASTM D7169, D7900, IP 545, IP 601, EN 15199-3, EN 15199-4

More Accurate Whole Crude Oil Analysis Optimizes Product Value

The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis. Standardization committees such as ASTM, IP and CEN are developing methods to allow the merging of a separate DHA analysis of the front end of a crude oil with the high temperature SIMDIS analysis. As a result of this merge, more accurate boiling point range data is obtained allowing precise cut point intervals determination for the whole crude oil. This allows for modeling end product closer to specs and ultimately less product give-away, while still meeting stringent product specifications.


The Crude Oil Analyzer (ASTM D7169) is the official standard for determination of the boiling point distribution and cut point intervals of crude oils and residues by using high temperature gas chromatography.

Applications: Crude

  • Based on high resolution DHA analysis to separate individual components for the light end of the crude oil up to and including C9 without quenching
  • Uses HT SIMDIS for the heavier components >C9 according to ASTM D7169
  • Built-in calculations ensure the amount residue (or sample recovery) is determined using an external standard
  • Intuitive AC software merges DHA and SIMDIS results into one boiling point distribution curve for the whole crude oil
  • Unique AC User Group with performance monitoring program (PMP)
  • Includes certified AC Quality Control Samples dedicated to crude oil

Proven Compliancy

  • Compliant with ASTM D7169, IP 545, IP 601 and EN 15199-3
  • Optional unique combi inlet allows analysis of both light end in crude oil (DHA FE) and light petroleum streams (naphtha/gasoline) conform ASTM D6729, D6730, D6733 and D5134
PAC AC Crude Oil Analyzer Philippines

For more information, contact us.

Related Products

ViscoLab PVT delivers accurate, fast, and reliable viscosity measurements in high-pressure environments.
ViscoLab PVT delivers accurate, fast, and reliable viscosity measurements in high-pressure environments.
The WAT-70Xi is the world’s first and only totally automatic process to measure WAT and WDT of crudes and marine fuel, capable of performing reliable testing of VLSFO and residual black oils.
The WAT-70Xi is the world’s first and only totally automatic process to measure WAT and WDT of crudes and marine fuel, capable of performing reliable testing of VLSFO and residual black oils.
The ViscoLab 3000 is a temperature-controlled viscometer that features an integrated heater to accurately deliver measurements at user-defined temperatures.
The ViscoLab 3000 is a temperature-controlled viscometer that features an integrated heater to accurately deliver measurements at user-defined temperatures.
Herzog’s automated Ubbelohde viscometers offer stability, ease of use, repeatability, and high sample throughput. It simultaneously tests up to two samples using standard Ubbelohde-style capillary tub
Herzog’s automated Ubbelohde viscometers offer stability, ease of use, repeatability, and high sample throughput. It simultaneously tests up to two samples using standard Ubbelohde-style capillary tub
The RB36 5G: Ring & Ball is designed for measuring product temperatures from 0°C to 220°C. The instrument enables simultaneous testing of two samples with independent monitoring.
The RB36 5G: Ring & Ball is designed for measuring product temperatures from 0°C to 220°C. The instrument enables simultaneous testing of two samples with independent monitoring.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Alcor’s MCRT-160 provides safe measurements of petroleum products with a tendency to thermally degrade and form coke under high temperature pyrolyzing conditions.
Alcor’s MCRT-160 provides safe measurements of petroleum products with a tendency to thermally degrade and form coke under high temperature pyrolyzing conditions.
ElemeNtS is the most advanced, modular, analytical system which detects Total Sulfur and/or Total Nitrogen efficiently using Ultraviolet Fluorescence (UVF) and Chemiluminescence (CLD) in solid, liquid
ElemeNtS is the most advanced, modular, analytical system which detects Total Sulfur and/or Total Nitrogen efficiently using Ultraviolet Fluorescence (UVF) and Chemiluminescence (CLD) in solid, liquid

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

Crude Oil Analyzer
Crude Oil Analyzer