ASTM D5800, CEC L 40 A 93, IP 421

ISL's safe, easy to use NCK2 5G Noack evaporation loss analyzer enables the most precise testing to meet increasing QS/QA requirements in full compliance with CEC, ASTM & IP methods.

NCK2 5Gs advanced quality control features including traceable automatic calibrations with lock-out control and detailed test reports with tracking numbers of all measuring devices fulfill strict ISO 9000 quality system requirements. The metal temperature probe is delivered with an engraved serial number and traceable calibration certificate.

The Noack oil coalescer air filters now comes in packs of 5 for increased savings. You can buy them on our Parts Store.

ASTM D5800, CEC L 40 A 93, IP 421

ISL’s safe, easy to use NCK2 5G Noack evaporation loss analyzer enables the most precise testing to meet increasing QS/QA requirements in full compliance with CEC, ASTM & IP methods.

NCK2 5Gs advanced quality control features including traceable automatic calibrations with lock-out control and detailed test reports with tracking numbers of all measuring devices fulfill strict ISO 9000 quality system requirements. The metal temperature probe is delivered with an engraved serial number and traceable calibration certificate.

The Noack oil coalescer air filters now comes in packs of 5 for increased savings. You can buy them on our Parts Store.

  • Powerful precision, versatile testing
    • Directly measures specimen temperature, providing evaporation loss characteristics in accordance to CEC, ASTM “Procedure B” and IP methods
    • Compact footprint and monoblock design
    • High sample throughput thanks to minimum downtime – Test Start either “Cold” or “Hot” mode
    • Optional tube heating for waxy application testing
    • Accurate visualization of Temperature and Pressure Curves
  • Enhanced safety and quality compliance
    • Heating without Wood’s alloy for increased safety & analysis precision
    • Automatic alarms and start test refusal in case of improper installation of sample probe and/ or crucible
    • Smart temperature probe with built-in memory chip transmits ID, offset values and calibration history to instrument
    • Detailed test reports with tracking numbers of measuring devices

Related Products

The ViscoLab 4000 is a small sample viscometer which supports up to 12 different 20:1 viscosity ranges; up to 10,000 cP with several output options.
The ViscoLab 4000 is a small sample viscometer which supports up to 12 different 20:1 viscosity ranges; up to 10,000 cP with several output options.
Phase Technology’s new JFA-70Xi jet fuel analyzer is the world’s first and only instrument that performs three crucial tests in one unit—freeze point, viscosity and density. And, it does it all in les
Phase Technology’s new JFA-70Xi jet fuel analyzer is the world’s first and only instrument that performs three crucial tests in one unit—freeze point, viscosity and density. And, it does it all in les
The Herzog 915 & 917 Gum Testers are designed to measure evaporation residue in aviation fuels, motor gasolines, and other volatile distillates.
The Herzog 915 & 917 Gum Testers are designed to measure evaporation residue in aviation fuels, motor gasolines, and other volatile distillates.
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.
PAC’s AC Analytical Controls offers the Hi-Speed Refinery Gas Analyzer, a high speed solution that determines and reports the composition of refinery gas streams in only five minutes.
PAC’s AC Analytical Controls offers the Hi-Speed Refinery Gas Analyzer, a high speed solution that determines and reports the composition of refinery gas streams in only five minutes.
The Herzog Multi-Range Viscometer HVM 472 determines direct kinematic viscosity of transparent and opaque liquids fully automated.
The Herzog Multi-Range Viscometer HVM 472 determines direct kinematic viscosity of transparent and opaque liquids fully automated.
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

Noack
Evaporation Loss
Noack
Evaporation Loss