Cold Filter Plugging Point

OptiFPP

CFPP: EN 116, EN 16329, IP 309, ASTM D 6371, JIS K 2288
CP: In accordance with ASTM D5771, IP 444, EN 23015, EN 590
In correlation to ASTM D2500, ISO 3015, IP 219, JIS K2269

The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument. The ISL OptiFPP analyzer provides automated CFPP test in strict accordance to EN116 and EN16329 conditions. OptiFPP precisely controls jacket cooling and electronically controlled vacuum adjusts as the test specimen is drawn though a mesh filter, per method conditions. Once crystal formation inhibits sample flow within a set time, a CFPP value is detected, displayed and stored to memory. Detailed reports are available, showing any abnormal points, as well as sample temperature behavior during the test.

CFPP: EN 116, EN 16329, IP 309, ASTM D 6371, JIS K 2288
CP: In accordance with ASTM D5771, IP 444, EN 23015, EN 590
In correlation to ASTM D2500, ISO 3015, IP 219, JIS K2269

The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument. The ISL OptiFPP analyzer provides automated CFPP test in strict accordance to EN116 and EN16329 conditions. OptiFPP precisely controls jacket cooling and electronically controlled vacuum adjusts as the test specimen is drawn though a mesh filter, per method conditions. Once crystal formation inhibits sample flow within a set time, a CFPP value is detected, displayed and stored to memory. Detailed reports are available, showing any abnormal points, as well as sample temperature behavior during the test.

  • Cable free heads contains both the electrical connections for the detector and a mechanical vacuum connection to the pipette.
  • Fully self-contained cooling system enables ultra-low temperature testing; saves energy; eliminates the heat, noise, external liquid connections and toxic coolant vapors of external cooling units
  • Real-time display of test progress and results
  • Stand-alone and/or PC controlled operation
  • Stepped or linear sample cooling in full compliance with EN 116 and EN 16329
  • Integrated auto-cleaning with two solvents can be operated while separate sample is running
  • Ability to run cloud point test with optional CP head

The Cloud Point Kit is available with a stainless steel and a glass temperature sensor. A complete measuring head with a probe, filter unit and pipet is also available for purchase.

CFPP: EN 116, EN 16329, IP 309, ASTM D 6371, JIS K 2288
CP: In accordance with ASTM D5771, IP 444, EN 23015, EN 590
In correlation to ASTM D2500, ISO 3015, IP 219, JIS K2269

The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument. The ISL OptiFPP analyzer provides automated CFPP test in strict accordance to EN116 and EN16329 conditions. OptiFPP precisely controls jacket cooling and electronically controlled vacuum adjusts as the test specimen is drawn though a mesh filter, per method conditions. Once crystal formation inhibits sample flow within a set time, a CFPP value is detected, displayed and stored to memory. Detailed reports are available, showing any abnormal points, as well as sample temperature behavior during the test.

Safety Data Sheet

 CRM Diesels SDS

Related Products

The ACCURA sampling device is designed for fully automated analysis of gaseous and pressurized liquid hydrocarbon streams for MultiTek and Gas Chromatography applications.
The ACCURA sampling device is designed for fully automated analysis of gaseous and pressurized liquid hydrocarbon streams for MultiTek and Gas Chromatography applications.
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.
Safe, easy to use ISL’s NCK2 5G Noack evaporation loss analyzer enables the most precise testing possible to meet increasing QS/QA requirements in full compliance with CEC, ASTM & IP methods.
Safe, easy to use ISL’s NCK2 5G Noack evaporation loss analyzer enables the most precise testing possible to meet increasing QS/QA requirements in full compliance with CEC, ASTM & IP methods.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Integrated diesel fuel analyzer for cloud point, pour point, viscosity, and density testing of petroleum diesel, renewable diesel, and biodiesel.
Integrated diesel fuel analyzer for cloud point, pour point, viscosity, and density testing of petroleum diesel, renewable diesel, and biodiesel.
ISL’s automated Mini Cloud Pour Point Analyzer is compact, portable and delivers fast results (30C in less than 30 minutes, and quick pour point correlation)
ISL’s automated Mini Cloud Pour Point Analyzer is compact, portable and delivers fast results (30C in less than 30 minutes, and quick pour point correlation)
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
The Herzog 915 & 917 Gum Testers are designed to measure evaporation residue in aviation fuels, motor gasolines, and other volatile distillates.
The Herzog 915 & 917 Gum Testers are designed to measure evaporation residue in aviation fuels, motor gasolines, and other volatile distillates.