Double Beam Spectrophotometer​

UH5300​

The technology for spectrophotometers continues to advance. Hitachi designs double beam spectrophotometers encompassing technologies for the future.​

 

Tags: Hitachi Double Beam Spectrophotometer​ UH5300​ ​Sigmatech Inc. Philippines
Key Industries: Batteries, Pharmaceutical, Water and Wastewater and more.
Features

Performance: This level of performance allows for highly accurate data to be obtained

  • Use of long-life xenon flash lamp
    Light source is guaranteed for seven years*1 resulting in lower operation cost
  • Double-beam optical system
    Ensures extended periods of data stability compared with the single-beam optical system.
    Best-of-class levels*2 of resolution of 1 nm have been achieved.


Comparison of baseline stability Single-beam device (above)
Double-beam device (below : UH5300)

Operation: Hitachi offers a new type of operation in laboratories.

  • Operation by use of tablet terminals or PC
    Simple and intuitive user interface
  • Remote control through wireless communication
    Flexible operating environment

A new way of operating a spectrophotometer

Other Features

  • Simple and easy-to-understand performance check function
    Assures the accuracy of data
  • Automatic 6-cell turret as standard equipment
    Improved efficiency and increased sample throughput

Software: Expand measurement possibilities just by touching the screen.

The control software is designed with emphasis on simple and intuitive operability, providing an easy-to-follow measurement flow, even for someone who is unfamiliar with a spectrophotometer.

Main menu of the UH5300

*1
Registration of the product is required. For further information, please ask your dealer. The lamp is guaranteed against failure for seven years after the date of delivery or for a specified number of lamp illuminations, whichever comes first.
The specified number of illuminations is represented as a percentage (%), depending on the working conditions of the lamps, in the maintenance menu of the UH5300, in reference to a lamp working condition of 100%.
Assuming that the spectrophotometer is used for seven years, 240 days a year, the lamp working condition of 100% corresponds to 300 measurement events of absorbance measurement per day (number of wavelengths : one wavelength) or 20 measurement events per day for of wavelength scan measurement per day (scan range : 190 to 1,100 nm, scan speed : 200 nm/min).
*2
Survey by Hitachi High-Tech Corporation. Models offered for sale in the Japanese market as of August, 2012.
*3
For more information about the system, please contact us.
*
Operation software is built into the UH5300
*
For information on AirPrint-compatible devices, see the Apple website

See more

 

Sigmatech Inc. Philippines is the leading provider of cutting-edge laboratory equipment crucial for a wide range of applications, including Quality Assurance/Quality Control (QA/QC), Metrology, Research and Development (R&D), Failure Analysis, Environmental and Chemical Analysis, and Process Control. Serving diverse industries in the Philippines, such as Semiconductor/Electronics, Pharmaceutical, Mining, Energy, and more, we are your go-to source for top-quality equipment, including Double Beam Spectrophotometers in the Philippines. About us

Related Products

With the highest level for 3D fluorescence spectra, F-7100 can be used in a wide range of applications from the cutting edge research to quality control.​
U-2900/2910 is a Double Beam Spectrophotometer mounting a large-size color LCD, which is simpler to use and higher in dependability.
Compact and affordable Karl Fischer coulometric moisture meter with high-level functions for accurate measurements in limited spaces.

VOC

The Teledyne Tekmar U-shaped trap offers trapping benefits that have never been seen before by Purge and Trap concentrators.
The Torch is considered the premium TOC combustion analyzer due to its many useful features and automated analysis processes. 
Compact, affordable, and versatile with a 4.3-inch touch panel, titration display, USB saving, and upgradeable from COM-28 to COM-28S.
The LA-960 combines the most popular modern sizing technique with state of the art refinements to measure wet and dry samples measuring 10 nanometers to 5 millimeters.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
Hitachi offers high-precision background correction and high-sensitivity measurement by employing the polarized Zeeman correction method alongside the dual detector method.
The Automatic Titrator has an 8.4-inch LCD touch panel, adjustable angles, USB data management, a thermal printer, and supports up to four simultaneous titrations.

How can we help?

You may contact our specialists by accomplishing form below.

Website menu

Download catalog

To download e-catalog, please submit your details below.

Hamamatsu Failure Analysis

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire About this Product

You may contact our specialists by accomplishing form below.

UH5300​
Double Beam Spectrophotometer​
UH5300​
Double Beam Spectrophotometer​