Opaque Long-Term Chamber

8200-104

The 8200-104 Opaque Long-Term Chamber builds on the trusted and patented technology from the previous generation. This line of long-term chambers withstands the elements with improvements to the design. The 8200-104 accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.

A motorized chamber finished in durable and reflective white enamel rotates away from your soil collar. This allows the soil in the collar to see natural environmental conditions when a measurement is not taking place. The chamber may be left unattended for extended periods of time to make automated measurements, with low power draw (7.5W maximum when opening or closing).

How are LI-COR chambers different?

The 8200-104 Opaque Long-Term Chamber and all LI-COR chambers have been carefully and intentionally designed to minimize their impact on the natural soil activity with consideration toward:

  • Maintaining chamber pressure with ambient air.
  • Achieving air mixing without a fan.
  • Accounting for the impact of altered diffusion gradient on the flux.
  • Minimizing the impact of the chamber on your soil environment.

 Learn more about the science and engineering behind the 8200-104 Opaque Long-Term Chamber.

8200-104 Chamber

Specifications

  • Dimensions: 48.3 cm L × 38.1 cm W × 33.0 cm H
  • Weight: 7.3 kg
  • Chamber Volume: 4076.1 cm3
  • Soil Area Exposed: 317.8 cm2
  • Weatherproof Rating: Tested to IEC IP55 standard
  • Air Temperature Thermistor:
    • Operating Range: -20 to 50 °C
    • Accuracy: ±0.3 °C from -20 to 50 °C
  • Light Sensor Current Input:
    • Range: 0 to 100 µA
    • Resolution: 1.5 nA
    • Accuracy: ±(0.37 % of Reading + 8 nA) from -20 to 50 °C
  • SDI-12 Communications Interface:
    • Max Number of Devices: 10
    • Output Voltage: 12 VDC, 200 mA

Specifications subject to change without notice.

Brochure

8250-02 Calibration Manifold Insert

Soil Gas Flux Measurement Solutions

Field guide to instruments for the earth sciences

Features

How are LI-COR chambers different?

The 8200-104 Opaque Long-Term Chamber and all LI-COR chambers have been carefully and intentionally designed to minimize their impact on the natural soil activity with consideration toward:

  • Maintaining chamber pressure with ambient air.
  • Achieving air mixing without a fan.
  • Accounting for the impact of altered diffusion gradient on the flux.
  • Minimizing the impact of the chamber on your soil environment.

 Learn more about the science and engineering behind the 8200-104 Opaque Long-Term Chamber.

8200-104 Chamber

Specifications

  • Dimensions: 48.3 cm L × 38.1 cm W × 33.0 cm H
  • Weight: 7.3 kg
  • Chamber Volume: 4076.1 cm3
  • Soil Area Exposed: 317.8 cm2
  • Weatherproof Rating: Tested to IEC IP55 standard
  • Air Temperature Thermistor:
    • Operating Range: -20 to 50 °C
    • Accuracy: ±0.3 °C from -20 to 50 °C
  • Light Sensor Current Input:
    • Range: 0 to 100 µA
    • Resolution: 1.5 nA
    • Accuracy: ±(0.37 % of Reading + 8 nA) from -20 to 50 °C
  • SDI-12 Communications Interface:
    • Max Number of Devices: 10
    • Output Voltage: 12 VDC, 200 mA

Specifications subject to change without notice.

Brochure

8250-02 Calibration Manifold Insert

Soil Gas Flux Measurement Solutions

Field guide to instruments for the earth sciences

Related Products

The LI-7820 N2O/H2O Trace Gas Analyzer offers high-precision nitrous oxide measurements in a low power, portable design—enabling it to easily integrate into survey and long-term soil flux systems.
A compact, rugged, easy-to-deploy, low-cost cellular solution for long-term, reliable field monitoring.
A single-channel thermocouple data logger to measure and record temperature in indoor environments.
A battery-powered rainfall data collection and recording system that includes a HOBO Pendant Event data logger integrated into a tipping-bucket rain gauge.
The LI-1500 allows for simple configuration of automated sampling to compute daily light integral (DLI) from PAR readings captured by LI-COR quantum sensors.
A high-accuracy, cost-effective data logger that measures and records conductivity and temperature in streams, lakes, and other freshwater sources.
The LI-193 Spherical Quantum Sensor measures PAR in air or underwater from all directions at depths up to 350 meters. This sensor is useful for studies of phytoplankton, which uses radiation from …
LI-830 and LI-850 are just right – bringing proven performance at an economical price to provide CO2 gas measurements that you can depend on day after day.
The HOBO TidbiT MX2205 is ideal for monitoring shallow waters, like streams and wetlands, or for monitoring soil in fields that are prone to flooding.
LI-COR eddy covariance systems measure the exchange of CO2, H2O, CH4 , and energy between the earth’s surface and the atmosphere, empowering researchers to advance scientific understanding of climate

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

8200-104
Opaque Long-Term Chamber
8200-104
Opaque Long-Term Chamber