Opaque Long-Term Chamber

8200-104

The 8200-104 Opaque Long-Term Chamber builds on the trusted and patented technology from the previous generation. This line of long-term chambers withstands the elements with improvements to the design. The 8200-104 accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.

A motorized chamber finished in durable and reflective white enamel rotates away from your soil collar. This allows the soil in the collar to see natural environmental conditions when a measurement is not taking place. The chamber may be left unattended for extended periods of time to make automated measurements, with low power draw (7.5W maximum when opening or closing).

How are LI-COR chambers different?

The 8200-104 Opaque Long-Term Chamber and all LI-COR chambers have been carefully and intentionally designed to minimize their impact on the natural soil activity with consideration toward:

  • Maintaining chamber pressure with ambient air.
  • Achieving air mixing without a fan.
  • Accounting for the impact of altered diffusion gradient on the flux.
  • Minimizing the impact of the chamber on your soil environment.

 Learn more about the science and engineering behind the 8200-104 Opaque Long-Term Chamber.

8200-104 Chamber

Specifications

  • Dimensions: 48.3 cm L × 38.1 cm W × 33.0 cm H
  • Weight: 7.3 kg
  • Chamber Volume: 4076.1 cm3
  • Soil Area Exposed: 317.8 cm2
  • Weatherproof Rating: Tested to IEC IP55 standard
  • Air Temperature Thermistor:
    • Operating Range: -20 to 50 °C
    • Accuracy: ±0.3 °C from -20 to 50 °C
  • Light Sensor Current Input:
    • Range: 0 to 100 µA
    • Resolution: 1.5 nA
    • Accuracy: ±(0.37 % of Reading + 8 nA) from -20 to 50 °C
  • SDI-12 Communications Interface:
    • Max Number of Devices: 10
    • Output Voltage: 12 VDC, 200 mA

Specifications subject to change without notice.

Brochure

8250-02 Calibration Manifold Insert

Soil Gas Flux Measurement Solutions

Field guide to instruments for the earth sciences

Features

How are LI-COR chambers different?

The 8200-104 Opaque Long-Term Chamber and all LI-COR chambers have been carefully and intentionally designed to minimize their impact on the natural soil activity with consideration toward:

  • Maintaining chamber pressure with ambient air.
  • Achieving air mixing without a fan.
  • Accounting for the impact of altered diffusion gradient on the flux.
  • Minimizing the impact of the chamber on your soil environment.

 Learn more about the science and engineering behind the 8200-104 Opaque Long-Term Chamber.

8200-104 Chamber

Specifications

  • Dimensions: 48.3 cm L × 38.1 cm W × 33.0 cm H
  • Weight: 7.3 kg
  • Chamber Volume: 4076.1 cm3
  • Soil Area Exposed: 317.8 cm2
  • Weatherproof Rating: Tested to IEC IP55 standard
  • Air Temperature Thermistor:
    • Operating Range: -20 to 50 °C
    • Accuracy: ±0.3 °C from -20 to 50 °C
  • Light Sensor Current Input:
    • Range: 0 to 100 µA
    • Resolution: 1.5 nA
    • Accuracy: ±(0.37 % of Reading + 8 nA) from -20 to 50 °C
  • SDI-12 Communications Interface:
    • Max Number of Devices: 10
    • Output Voltage: 12 VDC, 200 mA

Specifications subject to change without notice.

Brochure

8250-02 Calibration Manifold Insert

Soil Gas Flux Measurement Solutions

Field guide to instruments for the earth sciences

Related Products

The 8200-104 Opaque Long-Term Chamber accepts industry standard SDI-12 connections to include the sensors and measurements you want at each chamber.
Monitors room occupancy and indoor light changes to identify occupancy patterns and determine energy usage and potential savings.
An affordable, precise data logger that measures oxygen concentrations in lakes, streams, rivers, estuaries, and coastal waters.
This logger features 0.1% measurement accuracy, a polypropylene housing for use in both freshwater and saltwater, and a non-vented design for convenient and hassle-free deployment.
The LI-180 Spectrometer lets you capture the spectral composition of your light sources with a single click.
LI-830 and LI-850 are just right – bringing proven performance at an economical price to provide CO2 gas measurements that you can depend on day after day.
Monitors indoor light changes with an internal sensor and records light on/off conditions; ideal for building energy audits and light usage analysis.
A miniature, waterproof, value-priced, two-channel temperature and relative light level data logger.
The LI-8250 acts as a single point of access to interact with and control a LI-COR gas analyzer and up to 36 chambers or flasks.
The LI-3100C is a rugged bench-top instrument designed to quickly digitize the area, length, and width of leaves.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

8200-104
Opaque Long-Term Chamber
8200-104
Opaque Long-Term Chamber