In the last decade, there has been a worldwide growth in the interest for alternative fuels. Biodiesel Fatty Acid Methyl Esters (FAMEs) offer an alternative to fossil diesel fuel. FAME can be blended with petroleum diesel (mostly B5, B7 and B20) or used as pure biodiesel (B100).

The AC Analytical Controls Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. The analyzer is completely tested and calibrated according to specified methods and includes multiple sets of calibration components, internal standards, and reagents.

In the last decade, there has been a worldwide growth in the interest for alternative fuels. Biodiesel Fatty Acid Methyl Esters (FAMEs) offer an alternative to fossil diesel fuel. FAME can be blended with petroleum diesel (mostly B5, B7 and B20) or used as pure biodiesel (B100).

The AC Analytical Controls Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. The analyzer is completely tested and calibrated according to specified methods and includes multiple sets of calibration components, internal standards, and reagents.

Biodiesel Analyzer Philippines | PAC AC Analytical Controls Biodiesel All in One Analyzer

The Biodiesel All in One analyzer covers all the current chromatographic tests listed for the specification methods in one system (see below table).

MethodsAnalysisInletAnalysis Time
ASTM D6584Free & total glycerinOn-column (TPI)35 minutes
EN 14103
prEN16300
Ester and linolenic acid methyl ester content
Iodine Value
Split/splitless25 minutes
EN 14105Free & total glycerol, mono-, di-, and triglyceride contentOn-column (TPI)35 minutes
EN 14110Methanol contentSplit/splitless10 minutes

The AC Biodiesel All in One Analyzer uses a single Agilent 7890A Series GC with electronic pneumatics control (EPC), an AC proprietary TPI inlet, a Split/Split less inlet, two capillary columns, one programmable external capillary column oven, and two Flame Ionization Detectors.

Applications: BioFuels

High throughput, small footprint

  • Features a short analysis time
  • Automates analysis with an optional Automatic Liquid Sampler
  • Combines all relevant biodiesel applications within one flexible system for a complete biodiesel solution


Innovative system design

  • Decreases operator intervention with the secondary programmable column oven – no need for the removal of columns or other hardware when switching applications
  • Guarantees excellent long term results
  • Increases productivity to no down-time for column replacement or other maintenance
  • Decreases costs due to time savings on operator time and spare parts
  • Improves system up time in the lab

Meets standards

  • Complies with the latest updates from ASTM D6584, EN 14103, EN 14105, EN 14110 methods
  • Complies with and prEN 16300 for Iodine Value

Enhanced and user-friendly software

  • Reports all relevant information for each method
  • Calculates with no need for additional programming
  • Checks data against specification (pass/fail)
  • Ensures traceability through calibration data
  • Automates column performance checks for easy quality control

Enhanced features

  • Includes all calibration components, internal standards, and reagents for each method
  • Installs easily, and a qualified support engineer handles installation system on-site and familiarizes users with operation
BioDiesel Analyzer Philippines
BioDiesel Analyzer Philippines | PAC AC Analytical Controls Biodiesel All in One Analyzer

The PAC Powered by AC Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. For more information on the equipment, contact us.

Related Products

The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
Integrated diesel fuel analyzer for cloud point, pour point, viscosity, and density testing of petroleum diesel, renewable diesel, and biodiesel.
Integrated diesel fuel analyzer for cloud point, pour point, viscosity, and density testing of petroleum diesel, renewable diesel, and biodiesel.
The ViscoLab 3000 is a temperature-controlled viscometer that features an integrated heater to accurately deliver measurements at user-defined temperatures.
The ViscoLab 3000 is a temperature-controlled viscometer that features an integrated heater to accurately deliver measurements at user-defined temperatures.
OptiFuel comes in a rugged yet elegant design with a friendly user interface, which makes it ideal for refineries, pipelines, terminals, and mobile labs.
OptiFuel comes in a rugged yet elegant design with a friendly user interface, which makes it ideal for refineries, pipelines, terminals, and mobile labs.
ElemeNtS is the most advanced, modular, analytical system which detects Total Sulfur and/or Total Nitrogen efficiently using Ultraviolet Fluorescence (UVF) and Chemiluminescence (CLD) in solid, liquid
ElemeNtS is the most advanced, modular, analytical system which detects Total Sulfur and/or Total Nitrogen efficiently using Ultraviolet Fluorescence (UVF) and Chemiluminescence (CLD) in solid, liquid
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.
The RB36 5G: Ring & Ball is designed for measuring product temperatures from 0°C to 220°C. The instrument enables simultaneous testing of two samples with independent monitoring.
The RB36 5G: Ring & Ball is designed for measuring product temperatures from 0°C to 220°C. The instrument enables simultaneous testing of two samples with independent monitoring.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

BioDiesel All-in-One
BioDiesel All-in-One