In the last decade, there has been a worldwide growth in the interest for alternative fuels. Biodiesel Fatty Acid Methyl Esters (FAMEs) offer an alternative to fossil diesel fuel. FAME can be blended with petroleum diesel (mostly B5, B7 and B20) or used as pure biodiesel (B100).

The AC Analytical Controls Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. The analyzer is completely tested and calibrated according to specified methods and includes multiple sets of calibration components, internal standards, and reagents.

In the last decade, there has been a worldwide growth in the interest for alternative fuels. Biodiesel Fatty Acid Methyl Esters (FAMEs) offer an alternative to fossil diesel fuel. FAME can be blended with petroleum diesel (mostly B5, B7 and B20) or used as pure biodiesel (B100).

The AC Analytical Controls Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. The analyzer is completely tested and calibrated according to specified methods and includes multiple sets of calibration components, internal standards, and reagents.

Biodiesel Analyzer Philippines | PAC AC Analytical Controls Biodiesel All in One Analyzer

The Biodiesel All in One analyzer covers all the current chromatographic tests listed for the specification methods in one system (see below table).

MethodsAnalysisInletAnalysis Time
ASTM D6584Free & total glycerinOn-column (TPI)35 minutes
EN 14103
prEN16300
Ester and linolenic acid methyl ester content
Iodine Value
Split/splitless25 minutes
EN 14105Free & total glycerol, mono-, di-, and triglyceride contentOn-column (TPI)35 minutes
EN 14110Methanol contentSplit/splitless10 minutes

The AC Biodiesel All in One Analyzer uses a single Agilent 7890A Series GC with electronic pneumatics control (EPC), an AC proprietary TPI inlet, a Split/Split less inlet, two capillary columns, one programmable external capillary column oven, and two Flame Ionization Detectors.

Applications: BioFuels

High throughput, small footprint

  • Features a short analysis time
  • Automates analysis with an optional Automatic Liquid Sampler
  • Combines all relevant biodiesel applications within one flexible system for a complete biodiesel solution


Innovative system design

  • Decreases operator intervention with the secondary programmable column oven – no need for the removal of columns or other hardware when switching applications
  • Guarantees excellent long term results
  • Increases productivity to no down-time for column replacement or other maintenance
  • Decreases costs due to time savings on operator time and spare parts
  • Improves system up time in the lab

Meets standards

  • Complies with the latest updates from ASTM D6584, EN 14103, EN 14105, EN 14110 methods
  • Complies with and prEN 16300 for Iodine Value

Enhanced and user-friendly software

  • Reports all relevant information for each method
  • Calculates with no need for additional programming
  • Checks data against specification (pass/fail)
  • Ensures traceability through calibration data
  • Automates column performance checks for easy quality control

Enhanced features

  • Includes all calibration components, internal standards, and reagents for each method
  • Installs easily, and a qualified support engineer handles installation system on-site and familiarizes users with operation
BioDiesel Analyzer Philippines
BioDiesel Analyzer Philippines | PAC AC Analytical Controls Biodiesel All in One Analyzer

The PAC Powered by AC Biodiesel All in One analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single dedicated system. For more information on the equipment, contact us.

Related Products

OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.
The Optiflash accurately detects flashpoint from -30°C up to 300°C for petroleum products, biodiesels, solvents, chemicals, paint varnishes, fluxed bitumen and food and beverages.
The Optiflash accurately detects flashpoint from -30°C up to 300°C for petroleum products, biodiesels, solvents, chemicals, paint varnishes, fluxed bitumen and food and beverages.
The AC Analytical Controls® standard solutions cover a wide spectrum of petroleum, petrochemical, and natural gas analysis needs.
The AC Analytical Controls® standard solutions cover a wide spectrum of petroleum, petrochemical, and natural gas analysis needs.
Dedicated jet fuel analyzer integrating freeze point, viscosity, and density measurements for fast ASTM-compliant aviation fuel certification.
Dedicated jet fuel analyzer integrating freeze point, viscosity, and density measurements for fast ASTM-compliant aviation fuel certification.
Herzog’s automated Ubbelohde viscometers offer stability, ease of use, repeatability, and high sample throughput. It simultaneously tests up to two samples using standard Ubbelohde-style capillary tub
Herzog’s automated Ubbelohde viscometers offer stability, ease of use, repeatability, and high sample throughput. It simultaneously tests up to two samples using standard Ubbelohde-style capillary tub
The VIDA ML density meter is specifically designed for mobile laboratory applications providing accurate and repeatable density.
The VIDA ML density meter is specifically designed for mobile laboratory applications providing accurate and repeatable density.
Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
The Cetane Ignition Delay CID 510 is a compact and easy to use analyzer, with fully automatic analysis and calibration sequences, offering analysis with extremely high precision.
The Cetane Ignition Delay CID 510 is a compact and easy to use analyzer, with fully automatic analysis and calibration sequences, offering analysis with extremely high precision.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

BioDiesel All-in-One
BioDiesel All-in-One