Viscometer Bath

TVB 445

ASTM D445, ASTM D446, DIN 51562, IP 71, ISO 3104, ISO 3105, GOST 33

The ISL Manual Viscometer Bath TVB 445 is designed to perform a variety of accurate temperature controls required for general laboratory use or as a constant temperature bath. Complying to ASTM D445 standards, the TVB 445 meets the requirement of viscosity measurement for highly precise temperature control, but also can be applied to applications that require visual monitoring (crystal growing, density and reaction rate measurement, etc.)

The TVB 445 is easy to operate and accommodates up to seven standard capillary tubes. Its compact design features a durable, stainless steel housing and inner bath. A built-in cooling coil makes it ideal for sub-ambient applications, and bath windows and optional lighting provide visual monitoring capabilities.

ASTM D445, ASTM D446, DIN 51562, IP 71, ISO 3104, ISO 3105, GOST 33

The ISL Manual Viscometer Bath TVB 445 is designed to perform a variety of accurate temperature controls required for general laboratory use or as a constant temperature bath. Complying to ASTM D445 standards, the TVB 445 meets the requirement of viscosity measurement for highly precise temperature control, but also can be applied to applications that require visual monitoring (crystal growing, density and reaction rate measurement, etc.)

The TVB 445 is easy to operate and accommodates up to seven standard capillary tubes. Its compact design features a durable, stainless steel housing and inner bath. A built-in cooling coil makes it ideal for sub-ambient applications, and bath windows and optional lighting provide visual monitoring capabilities.

PAC ISL TVB 445: Viscometer Bath Features

  • Accommodates up to 7 capillary tubes (8 upon request)
  • Accommodates sub-ambient conditions with a built-in cooling coil
  • Saves space with its compact design
  • Detachable windows for easy cleaning of the inner window
  • Provides standard bath with RS-232 communication link
  • Meets ASTM D445 and IP 71 methods
  • Provides accurate measurement over a wide temperature range (0.1ºC setpoint to 200ºC)
  • Offers stability and uniformity of 0.01ºC*
  • Provides multiple safety features to ensure effective bath insulation against heat loss
  • Corrosion-resistant material using stainless steel and PTFE
  • Control module for temperature measurement and regulation

* values measured in water @ 50 C (122 F)

TVB 445_ Viscometer Bath

For more information, contact us.

Related Products

World’s first fully integrated fuel analyzer combining freeze point, cloud point, pour point, viscosity, and density testing in one automated platform for rapid jet fuel and diesel analysis.
World’s first fully integrated fuel analyzer combining freeze point, cloud point, pour point, viscosity, and density testing in one automated platform for rapid jet fuel and diesel analysis.
Building on Excellence, Strengthening the Benchmark for Atmospheric Distillation.
Building on Excellence, Strengthening the Benchmark for Atmospheric Distillation.
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
The Alcor Intelligent Heater Tube™ (IHT) ensures traceable, accurate, and secure jet fuel thermal oxidation testing.
The Alcor Intelligent Heater Tube™ (IHT) ensures traceable, accurate, and secure jet fuel thermal oxidation testing.
ISL’s automated Mini Cloud Pour Point Analyzer is compact, portable and delivers fast results (30C in less than 30 minutes, and quick pour point correlation)
ISL’s automated Mini Cloud Pour Point Analyzer is compact, portable and delivers fast results (30C in less than 30 minutes, and quick pour point correlation)
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.
SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

TVB 445
Viscometer Bath
TVB 445
Viscometer Bath