Viscometer Bath

TVB 445

ASTM D445, ASTM D446, DIN 51562, IP 71, ISO 3104, ISO 3105, GOST 33

The ISL Manual Viscometer Bath TVB 445 is designed to perform a variety of accurate temperature controls required for general laboratory use or as a constant temperature bath. Complying to ASTM D445 standards, the TVB 445 meets the requirement of viscosity measurement for highly precise temperature control, but also can be applied to applications that require visual monitoring (crystal growing, density and reaction rate measurement, etc.)

The TVB 445 is easy to operate and accommodates up to seven standard capillary tubes. Its compact design features a durable, stainless steel housing and inner bath. A built-in cooling coil makes it ideal for sub-ambient applications, and bath windows and optional lighting provide visual monitoring capabilities.

ASTM D445, ASTM D446, DIN 51562, IP 71, ISO 3104, ISO 3105, GOST 33

The ISL Manual Viscometer Bath TVB 445 is designed to perform a variety of accurate temperature controls required for general laboratory use or as a constant temperature bath. Complying to ASTM D445 standards, the TVB 445 meets the requirement of viscosity measurement for highly precise temperature control, but also can be applied to applications that require visual monitoring (crystal growing, density and reaction rate measurement, etc.)

The TVB 445 is easy to operate and accommodates up to seven standard capillary tubes. Its compact design features a durable, stainless steel housing and inner bath. A built-in cooling coil makes it ideal for sub-ambient applications, and bath windows and optional lighting provide visual monitoring capabilities.

PAC ISL TVB 445: Viscometer Bath Features

  • Accommodates up to 7 capillary tubes (8 upon request)
  • Accommodates sub-ambient conditions with a built-in cooling coil
  • Saves space with its compact design
  • Detachable windows for easy cleaning of the inner window
  • Provides standard bath with RS-232 communication link
  • Meets ASTM D445 and IP 71 methods
  • Provides accurate measurement over a wide temperature range (0.1ºC setpoint to 200ºC)
  • Offers stability and uniformity of 0.01ºC*
  • Provides multiple safety features to ensure effective bath insulation against heat loss
  • Corrosion-resistant material using stainless steel and PTFE
  • Control module for temperature measurement and regulation

* values measured in water @ 50 C (122 F)

TVB 445_ Viscometer Bath

For more information, contact us.

Related Products

Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
The Cetane Ignition Delay CID 510 is a compact and easy to use analyzer, with fully automatic analysis and calibration sequences, offering analysis with extremely high precision.
The Cetane Ignition Delay CID 510 is a compact and easy to use analyzer, with fully automatic analysis and calibration sequences, offering analysis with extremely high precision.
The VIDA ML density meter is specifically designed for mobile laboratory applications providing accurate and repeatable density.
The VIDA ML density meter is specifically designed for mobile laboratory applications providing accurate and repeatable density.
Safe, easy to use ISL’s NCK2 5G Noack evaporation loss analyzer enables the most precise testing possible to meet increasing QS/QA requirements in full compliance with CEC, ASTM & IP methods.
Safe, easy to use ISL’s NCK2 5G Noack evaporation loss analyzer enables the most precise testing possible to meet increasing QS/QA requirements in full compliance with CEC, ASTM & IP methods.
Building on Excellence, Strengthening the Benchmark for Atmospheric Distillation.
Building on Excellence, Strengthening the Benchmark for Atmospheric Distillation.
The ACCURA sampling device is designed for fully automated analysis of gaseous and pressurized liquid hydrocarbon streams for MultiTek and Gas Chromatography applications.
The ACCURA sampling device is designed for fully automated analysis of gaseous and pressurized liquid hydrocarbon streams for MultiTek and Gas Chromatography applications.
The AC Analytical Controls Biodiesel All in One Analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single system
The AC Analytical Controls Biodiesel All in One Analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results fast from a single system
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

TVB 445
Viscometer Bath
TVB 445