Sulfur Nitrogen Selective Detector

SeNSe²

ASTM D5504, ASTM D5623, ASTM D7011, ASTM D7807

SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices. While still based on the Chemiluminescence principle that was employed first in the Antek 7090NS model, the detector has undergone a significant redesign to provide unsurpassed sensitivity resulting in lower detection limits, excellent equimolar response, dynamic range and selectivity. A fast cold start-up, unrivalled signal stability, the sturdy but compact design, and the touchscreen interface makes it the easiest to work with.

 

Applications: GC Detector

 

Key Industries: Oil and Gas and more.

Maintenance and Ease of Use

  • Ingenious G-Cal Service module used for testing the function of the detector without disassembling the configuration
  • Simplified preventative maintenance with removable panels and fast ceramics replacement
  • 7” Touchscreen interface providing both standalone operation and providing insight into your detector diagnostics and error logs
  • Able to be installed on most manufacturers GCs
  • All routine maintenance, including GC column replacement, can be achieved without shutting down the system


Performance

  • Excellent long-term stability and equimolarity
  • Heavy duty insulation to maintain furnace temperature at 950°C leading to improved temperature accuracy across the whole furnace
  • Integrated filters to purify incoming gases boosting data integrity
  • Standalone automated pressure and leak check to guarantee leak-free performance
  • For sulfur analysis, system choice of oxygen or air as an oxidant based on laboratory need

Turnkey Solutions

  • ASTM D5504: Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence
  • ASTM D5623: Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7011: Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7807: Determination of Boiling Range Distribution of Hydrocarbon and Sulfur Components of Petroleum Distillates by Gas Chromatography and Chemiluminescence Detection
  • Custom Application like carbonyl sulfide in propylene gas, nitric oxide in ethylene and more
Features

Maintenance and Ease of Use

  • Ingenious G-Cal Service module used for testing the function of the detector without disassembling the configuration
  • Simplified preventative maintenance with removable panels and fast ceramics replacement
  • 7” Touchscreen interface providing both standalone operation and providing insight into your detector diagnostics and error logs
  • Able to be installed on most manufacturers GCs
  • All routine maintenance, including GC column replacement, can be achieved without shutting down the system


Performance

  • Excellent long-term stability and equimolarity
  • Heavy duty insulation to maintain furnace temperature at 950°C leading to improved temperature accuracy across the whole furnace
  • Integrated filters to purify incoming gases boosting data integrity
  • Standalone automated pressure and leak check to guarantee leak-free performance
  • For sulfur analysis, system choice of oxygen or air as an oxidant based on laboratory need

Turnkey Solutions

  • ASTM D5504: Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence
  • ASTM D5623: Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7011: Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7807: Determination of Boiling Range Distribution of Hydrocarbon and Sulfur Components of Petroleum Distillates by Gas Chromatography and Chemiluminescence Detection
  • Custom Application like carbonyl sulfide in propylene gas, nitric oxide in ethylene and more

Related Products

The AC Analytical Controls® standard solutions cover a wide spectrum of petroleum, petrochemical, and natural gas analysis needs.
ViscoLab PVT+ delivers accurate, fast, and reliable viscosity measurements in high-pressure environments.
The Crude Oil Analyzer combines the results of DHA Front End (FE) and High Temp (HT) SIMDIS analyses into one total true boiling point (TBP) report for the best performance in crude oil analysis.
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
Results are not only fast, but also highly precise and accurate. The user interface is so simple it doesn’t require any training which saves time and money.
The Herzog Multi-Range Viscometer HVM 472 determines direct kinematic viscosity of transparent and opaque liquids fully automated.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.
The ACCURA sampling device is designed for fully automated analysis of gaseous and pressurized liquid hydrocarbon streams for MultiTek and Gas Chromatography applications.
PAC’s AC Analytical Controls offers the Hi-Speed Refinery Gas Analyzer, a high speed solution that determines and reports the composition of refinery gas streams in only five minutes.
PAC’s Alcor JFTOT® IV is the globally recognized standard for jet fuel thermal oxidation testing with a worldwide installed base of over 1,000 instruments.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

SeNSe²
Sulfur Nitrogen Selective Detector
SeNSe²
Sulfur Nitrogen Selective Detector