X-ray Fluorescence Sulfur/ Chlorine-in-oil Analyzer

MESA-7220V2

The MESA-7220V2 measures both sulfur and chlorine in petroleum based products using the Monochromatic Energy Dispersive X-ray Fluorescence (EDXRF) method. A monochromatic X-ray source is used in order to obtain an ultra-low noise background which affords the best detection limits for both sulfur and chlorine.

The detector window size was increased to collect more fluorescent X-rays and thus achieve lower level ppm values. This provides excellent, repeatable performance at both low and high concentrations of both elements.

The MESA-7220V2 measures both sulfur and chlorine in petroleum based products using the Monochromatic Energy Dispersive X-ray Fluorescence (EDXRF) method. A monochromatic X-ray source is used in order to obtain an ultra-low noise background which affords the best detection limits for both sulfur and chlorine.

The detector window size was increased to collect more fluorescent X-rays and thus achieve lower level ppm values. This provides excellent, repeatable performance at both low and high concentrations of both elements.

  •   Dynamic Analysis Range
    Sulfur:      0.7 ppm – 10.0Wt%
    Chlorine:  0.6 ppm – 10.0Wt%

•    Auto Ranging for extended curves.
•    No purge gases required.
•    Maximum 60 calibration curves and 300 data points per curve.
•    Calibration curves can be edited after they have been saved.
•    Measurement times from 30 – 999 sec.
•    Measurement repeats from 1 – 99 times.
•    Oxygen correction feature eliminates interference which can affect Sulfur readings.
•    Various sample types* [Solids, Liquids, Powders, Pastes, Pellets, and Films] can be measured.
•    Can program up to 20 Admin & User accounts.
•    User replaceable Kapton window.
•    Micrometer adjustment of graphite crystal angle for better sensitivity.
•    Stand-alone PC to allow software updates electronically.
•    Built-in interlocks to protect end-user from X-rays.
•    Silicon Drift Detector/X-ray Beryllium Window.

Related Products

Semi-Automatic Hydraulic Presses are available in 8 Ton, 15 Ton and 25 Ton load configurations.
Semi-Automatic Hydraulic Presses are available in 8 Ton, 15 Ton and 25 Ton load configurations.
The LA-960 combines the most popular modern sizing technique with state of the art refinements to measure wet and dry samples measuring 10 nanometers to 5 millimeters.
The LA-960 combines the most popular modern sizing technique with state of the art refinements to measure wet and dry samples measuring 10 nanometers to 5 millimeters.
The ASX-560 four-rack autosampler is a compact and efficient solution for medium- to high-volume sample applications, capable of holding up to 360 samples.
The ASX-560 four-rack autosampler is a compact and efficient solution for medium- to high-volume sample applications, capable of holding up to 360 samples.
The Teledyne LABS ASXpress® Plus Rapid Sample Injection System reduces the time required for autosampler movement, sample uptake, stabilization, and rinse operations with ICP-OES and ICP-MS. The resul
The Teledyne LABS ASXpress® Plus Rapid Sample Injection System reduces the time required for autosampler movement, sample uptake, stabilization, and rinse operations with ICP-OES and ICP-MS. The resul
A high‑performance benchtop FTIR, the IR5 is ideal for everyday analysis, delivering fast and accurate IR measurements.
A high‑performance benchtop FTIR, the IR5 is ideal for everyday analysis, delivering fast and accurate IR measurements.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
DSC is used to measure heat flow for material characterization by providing thermal properties such as melting point, glass transition and crystallization.
DSC is used to measure heat flow for material characterization by providing thermal properties such as melting point, glass transition and crystallization.
The UH5300 is controllable through a tablet terminal (iPad or Windows 10) offering new levels of access, control, and operation.
The UH5300 is controllable through a tablet terminal (iPad or Windows 10) offering new levels of access, control, and operation.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

MESA-7220V2
X-ray Fluorescence Sulfur/ Chlorine-in-oil Analyzer
MESA-7220V2
X-ray Fluorescence Sulfur/ Chlorine-in-oil Analyzer