Pyranometer

LI-200R

The LI-200R Pyranometer is meant to be used outdoors under unobstructed natural daylight conditions. It measures global solar radiation—the combination of direct and diffuse solar radiation—in the 400 to 1100 nm range. Measurement units are in watts per square meter (W m-2).

Ideal for agricultural, meteorological, solar energy, and environmental research, the LI-200R is available with a variety of cable lengths and compatibility with most data loggers.

Why choose the LI-200R?

  • Weather resistant and durable in long-term outdoor deployments
  • Measures global solar radiation under unobstructed natural daylight conditions
  • Uniform sensitivity up to 82° incident angle
  • Detachable sensor simplifies installation and removal, making it ideal for platforms with complex cabling
LI-200R

How does it work?

The LI-200R measures global solar radiation with an unfiltered silicon photodiode. Its measurements correspond closely to first-class thermopiles when used outdoors under unobstructed natural daylight conditions.

The crown of the sensor rapidly sheds water, and also physically blocks light from outside the hemisphere of sensitivity, providing a precise cosine response.

Photometric Response Diagram
Typical spectral response of the LI-210R Photometric Sensor

LI-200R Specifications

  • Absolute Calibration: Calibrated against an Eppley Precision Spectral Pyranometer (PSP) under natural daylight conditions. Calibration uncertainty under these conditions is estimated as ± 3% typical, within ± 60° angle of incidence.*
  • Sensitivity: Typically 75 μA per 1,000 W m-2
  • Linearity: Maximum deviation of 1% up to 3,000 W m-2
  • Response Time: Less than 1 μs (2 m cable terminated into a 147 Ohm load)
  • Temperature Dependence: ± 0.15% per °C maximum
  • Cosine Correction: Cosine corrected up to 82° angle of incidence
  • Azimuth: < ± 1% error over 360° at 45° elevation
  • Tilt: No error induced from orientation
  • Operating Temperature Range: −40 °C to 65 °C
  • Relative Humidity Range: 0% to 100% RH, Non-Condensing
  • Detector: High stability silicon photovoltaic detector (blue enhanced)
  • Sensor Housing: Weatherproof anodized aluminum body with acrylic diffuser and stainless steel hardware; O-ring seal on the sensor base
  • Size: 2.36 cm diameter × 3.63 cm (0.93” × 1.43”)
  • Weight: 24 g head; 60 g base and cable (2 m) with screws
  • Cable Length: 2 m, 5 m, 15 m, 50 m (6.5’, 16.4’, 49.2’, 164’)

*Preliminary specification

LI-COR LI-200R Pyranometer Philippines – Sigmatech Inc.

LI-200R Pyranometer Philippines

Brochures

Light Measurement

Light Measurement Solutions for Greenhouse Management

LI-1500 Light Sensor Logger

Principles of Radiation Measurement

Field guide to instruments for the earth sciences

Features

Why choose the LI-200R?

  • Weather resistant and durable in long-term outdoor deployments
  • Measures global solar radiation under unobstructed natural daylight conditions
  • Uniform sensitivity up to 82° incident angle
  • Detachable sensor simplifies installation and removal, making it ideal for platforms with complex cabling
LI-200R

How does it work?

The LI-200R measures global solar radiation with an unfiltered silicon photodiode. Its measurements correspond closely to first-class thermopiles when used outdoors under unobstructed natural daylight conditions.

The crown of the sensor rapidly sheds water, and also physically blocks light from outside the hemisphere of sensitivity, providing a precise cosine response.

Cosine Response at an angle of incidence of 80 degrees

 Learn more about the science and engineering behind the new design

LI-200R Specifications

  • Absolute Calibration: Calibrated against an Eppley Precision Spectral Pyranometer (PSP) under natural daylight conditions. Calibration uncertainty under these conditions is estimated as ± 3% typical, within ± 60° angle of incidence.*
  • Sensitivity: Typically 75 μA per 1,000 W m-2
  • Linearity: Maximum deviation of 1% up to 3,000 W m-2
  • Response Time: Less than 1 μs (2 m cable terminated into a 147 Ohm load)
  • Temperature Dependence: ± 0.15% per °C maximum
  • Cosine Correction: Cosine corrected up to 82° angle of incidence
  • Azimuth: < ± 1% error over 360° at 45° elevation
  • Tilt: No error induced from orientation
  • Operating Temperature Range: −40 °C to 65 °C
  • Relative Humidity Range: 0% to 100% RH, Non-Condensing
  • Detector: High stability silicon photovoltaic detector (blue enhanced)
  • Sensor Housing: Weatherproof anodized aluminum body with acrylic diffuser and stainless steel hardware; O-ring seal on the sensor base
  • Size: 2.36 cm diameter × 3.63 cm (0.93” × 1.43”)
  • Weight: 24 g head; 60 g base and cable (2 m) with screws
  • Cable Length: 2 m, 5 m, 15 m, 50 m (6.5’, 16.4’, 49.2’, 164’)

*Preliminary specification

Brochures

Light Measurement

Light Measurement Solutions for Greenhouse Management

LI-1500 Light Sensor Logger

Principles of Radiation Measurement

Field guide to instruments for the earth sciences

Related Products

A waterproof temperature/light-level logger using the power of Bluetooth to deliver accurate data straight to your mobile device or Windows computer running our free HOBOconnect app.
Designed for long-term monitoring of pH in estuaries, lakes, streams, rivers, and oceans.
Intuitive and very easy to use touch panel operation. Easy to clean glass top and round body. Horiba LAQUA Benchtop Type Water Quality Meter is both easy and fun to use!
With an integrated sensor, measures and records temperature in indoor environments.
The 8200-104C Clear Long-Term Chamber has been specially designed for NCE measurements. It includes technology and patents designed to minimize chamber impact on natural plant and soil activity with c
The most flexible remote data logging station from HOBO Data Loggers, the HOBO RX3000 provides instant access to site-specific environmental data anywhere, at any time, via the internet.
Enabled with cellular communication, this award-winning remote water level monitoring station completes calculations onsite and sends notifications of critical conditions via cellular plans to LI-COR
The LI-191R Line Quantum Sensor measures PAR integrated over its 1-meter length. It is used to measure sunlight under a plant canopy, where the light field is non-uniform.
A high-performance, LCD display data logger, supporting up to four external sensors to measure and record parameters such as temperature, current, voltages, and third-party sensors. 
Measures and records CO2 in buildings and other non-condensing environments.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

LI-200R
Pyranometer
LI-200R