Photometric Sensor

LI-210R

The LI-210R Photometric Sensor measures light with the same sensitivity as a typical human eye. The photometric sensor is ideal for evaluating illumination in work areas, exhibits, interior lighting, and in public spaces. Measurement units are lux or klux.

Why choose the LI-210R Photometric Sensor?

  • Spectral response closely matches the CIE Standard observer Curve
  • Excellent cosine response—sensitive to light from all directions up to an 82° angle of incidence
  • Detachable sensor simplifies installation and removal, making it ideal for platforms with complex cabling

How does it work?

The LI-210R measures light with a precision filtered silicon photodiode that is sensitive to light in the visible spectrum.

Photometric Response Diagram
Typical spectral response of the LI-210R Photometric Sensor
Cosine Response at an angle of incidence of 80 degrees

 Learn more about the science and engineering behind the new design

LI-210R Specifications

  • Absolute Calibration: ± 5% traceable to the U.S. National Institute of Standards and Technology (NIST)
  • Sensitivity: Typically 30 μA per 100 klux
  • Linearity: Maximum deviation of 1% up to 100 klux
  • Response Time: Less than 1 μs (2 m cable terminated into a 604 Ohm load)
  • Temperature Dependence: ± 0.15% per °C maximum
  • Cosine Correction: Cosine corrected up to 82° angle of incidence
  • Azimuth: < ± 1% error over 360° at 45° elevation
  • Tilt: No error induced from orientation
  • Operating Temperature Range: −40 °C to 65 °C
  • Relative Humidity Range: 0% to 100% RH, Non-Condensing
  • Detector: High stability silicon photovoltaic detector (blue enhanced)
  • Sensor Housing: Weatherproof anodized aluminum housing with acrylic diffuser and stainless steel hardware; O-ring seal on the sensor base
  • Size: 2.36 cm Diameter × 3.63 cm (0.93” × 1.43”)
  • Weight: 24 g head; 60 g base/cable (2 m) with screws
  • Cable Length: 2 m, 5 m, 15 m, 50 m (6.5’, 16.4’, 49.2’, 164’)

For more information, contact us.

Brochures

Light Measurement

Light Measurement Solutions for Greenhouse Management

LI-1500 Light Sensor Logger

Principles of Radiation Measurement

Field guide to instruments for the earth sciences

Features

Why choose the LI-210R?

  • Spectral response closely matches the CIE Standard observer Curve
  • Excellent cosine response—sensitive to light from all directions up to an 82° angle of incidence
  • Detachable sensor simplifies installation and removal, making it ideal for platforms with complex cabling

How does it work?

The LI-210R measures light with a precision filtered silicon photodiode that is sensitive to light in the visible spectrum.

Photometric Response Diagram
Typical spectral response of the LI-210R Photometric Sensor
Cosine Response at an angle of incidence of 80 degrees

 Learn more about the science and engineering behind the new design

LI-210R Specifications

  • Absolute Calibration: ± 5% traceable to the U.S. National Institute of Standards and Technology (NIST)
  • Sensitivity: Typically 30 μA per 100 klux
  • Linearity: Maximum deviation of 1% up to 100 klux
  • Response Time: Less than 1 μs (2 m cable terminated into a 604 Ohm load)
  • Temperature Dependence: ± 0.15% per °C maximum
  • Cosine Correction: Cosine corrected up to 82° angle of incidence
  • Azimuth: < ± 1% error over 360° at 45° elevation
  • Tilt: No error induced from orientation
  • Operating Temperature Range: −40 °C to 65 °C
  • Relative Humidity Range: 0% to 100% RH, Non-Condensing
  • Detector: High stability silicon photovoltaic detector (blue enhanced)
  • Sensor Housing: Weatherproof anodized aluminum housing with acrylic diffuser and stainless steel hardware; O-ring seal on the sensor base
  • Size: 2.36 cm Diameter × 3.63 cm (0.93” × 1.43”)
  • Weight: 24 g head; 60 g base/cable (2 m) with screws
  • Cable Length: 2 m, 5 m, 15 m, 50 m (6.5’, 16.4’, 49.2’, 164’)

Brochures

Light Measurement

Light Measurement Solutions for Greenhouse Management

LI-1500 Light Sensor Logger

Principles of Radiation Measurement

Field guide to instruments for the earth sciences

Related Products

A high-accuracy, easy-to-deploy data logger that measures and records the power and energy consumption of 120V plug loads from office equipment, vending machines, and other devices.
A high-performance, LCD display data logger, supporting up to four external sensors to measure and record parameters such as temperature, current, voltages, and third-party sensors. 
A waterproof logger that uses the power of Bluetooth to deliver accurate temperature measurements straight to your mobile device or Windows computer running our free HOBOconnect app.
Choose the LI-250Q package for spot measurements of photosynthetically active radiation (PAR) intensity and quantity with unrivaled accuracy.
Get rapid insights into stomatal conductance, chlorophyll fluorescence, and leaf angle for a variety of leaf sizes and morphologies, including many needles and narrow grasses.
A durable water temperature data logger with 12-bit resolution.
Rugged and Bluetooth-enabled, the MX2308 delivers research-grade monitoring of key growing conditions—photosynthetically active radiation (PAR), temperature and relative humidity—all in a single devic
Designed for long-term monitoring of pH in estuaries, lakes, streams, rivers, and oceans.
An affordable, precise data logger that measures oxygen concentrations in lakes, streams, rivers, estuaries, and coastal waters.
Records state changes, electronic pulses, and mechanical or electrical contact closures from external sensing devices.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

LI-210R
Photometric Sensor
LI-210R
Photometric Sensor