Sulfur Nitrogen Selective Detector

SeNSe²

ASTM D5504, ASTM D5623, ASTM D7011, ASTM D7807

SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices. While still based on the Chemiluminescence principle that was employed first in the Antek 7090NS model, the detector has undergone a significant redesign to provide unsurpassed sensitivity resulting in lower detection limits, excellent equimolar response, dynamic range and selectivity. A fast cold start-up, unrivalled signal stability, the sturdy but compact design, and the touchscreen interface makes it the easiest to work with.

 

Applications: GC Detector

 

ASTM D5504, ASTM D5623, ASTM D7011, ASTM D7807

SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices. While still based on the Chemiluminescence principle that was employed first in the Antek 7090NS model, the detector has undergone a significant redesign to provide unsurpassed sensitivity resulting in lower detection limits, excellent equimolar response, dynamic range and selectivity. A fast cold start-up, unrivalled signal stability, the sturdy but compact design, and the touchscreen interface makes it the easiest to work with.

 

Applications: GC Detector

 

Maintenance and Ease of Use

  • Ingenious G-Cal Service module used for testing the function of the detector without disassembling the configuration
  • Simplified preventative maintenance with removable panels and fast ceramics replacement
  • 7” Touchscreen interface providing both standalone operation and providing insight into your detector diagnostics and error logs
  • Able to be installed on most manufacturers GCs
  • All routine maintenance, including GC column replacement, can be achieved without shutting down the system


Performance

  • Excellent long-term stability and equimolarity
  • Heavy duty insulation to maintain furnace temperature at 950°C leading to improved temperature accuracy across the whole furnace
  • Integrated filters to purify incoming gases boosting data integrity
  • Standalone automated pressure and leak check to guarantee leak-free performance
  • For sulfur analysis, system choice of oxygen or air as an oxidant based on laboratory need

Turnkey Solutions

  • ASTM D5504: Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence
  • ASTM D5623: Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7011: Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7807: Determination of Boiling Range Distribution of Hydrocarbon and Sulfur Components of Petroleum Distillates by Gas Chromatography and Chemiluminescence Detection
  • Custom Application like carbonyl sulfide in propylene gas, nitric oxide in ethylene and more

Related Products

ISL’s automated Mini Cloud Pour Point Analyzer is compact, portable and delivers fast results (30C in less than 30 minutes, and quick pour point correlation)
ISL’s automated Mini Cloud Pour Point Analyzer is compact, portable and delivers fast results (30C in less than 30 minutes, and quick pour point correlation)
The ViscoLab 4000 is a small sample viscometer which supports up to 12 different 20:1 viscosity ranges; up to 10,000 cP with several output options.
The ViscoLab 4000 is a small sample viscometer which supports up to 12 different 20:1 viscosity ranges; up to 10,000 cP with several output options.
The Herzog 915 & 917 Gum Testers are designed to measure evaporation residue in aviation fuels, motor gasolines, and other volatile distillates.
The Herzog 915 & 917 Gum Testers are designed to measure evaporation residue in aviation fuels, motor gasolines, and other volatile distillates.
Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
Using a “Houillon” capillary tube, ISL’s VH Series Viscometers automatically determine kinematic viscosity of lubricating oils, used oils, fuels, polymers, and similar materials over a wide viscosity
Herzog’s HVP 972 Vapor Pressure Analyzer is the modern analytical instrument designed for accurate determination of vapor pressure.
Herzog’s HVP 972 Vapor Pressure Analyzer is the modern analytical instrument designed for accurate determination of vapor pressure.
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.
OptiPMD determines the boiling range characteristics of petroleum products in less than 10 minutes, using only 10 ml of sample and it’s included in at least 10 fuel specifications.
Phase Technology’s new JFA-70Xi jet fuel analyzer is the world’s first and only instrument that performs three crucial tests in one unit—freeze point, viscosity and density. And, it does it all in les
Phase Technology’s new JFA-70Xi jet fuel analyzer is the world’s first and only instrument that performs three crucial tests in one unit—freeze point, viscosity and density. And, it does it all in les
PAC’s Alcor JFTOT® IV is the globally recognized standard for jet fuel thermal oxidation testing with a worldwide installed base of over 1,000 instruments.
PAC’s Alcor JFTOT® IV is the globally recognized standard for jet fuel thermal oxidation testing with a worldwide installed base of over 1,000 instruments.

Product added to Quote list ✔