Sulfur Nitrogen Selective Detector

SeNSe²

ASTM D5504, ASTM D5623, ASTM D7011, ASTM D7807

SeNSe2 is a new detector that has been developed by AC Analytical Controls by PAC for Gas Chromatography applications aiming to determine Sulfur species in hydrocarbon type matrices. While still based on the Chemiluminescence principle that was employed first in the Antek 7090NS model, the detector has undergone a significant redesign to provide unsurpassed sensitivity resulting in lower detection limits, excellent equimolar response, dynamic range and selectivity. A fast cold start-up, unrivalled signal stability, the sturdy but compact design, and the touchscreen interface makes it the easiest to work with.

 

Applications: GC Detector

 

Key Industries: Oil and Gas and more.

Maintenance and Ease of Use

  • Ingenious G-Cal Service module used for testing the function of the detector without disassembling the configuration
  • Simplified preventative maintenance with removable panels and fast ceramics replacement
  • 7” Touchscreen interface providing both standalone operation and providing insight into your detector diagnostics and error logs
  • Able to be installed on most manufacturers GCs
  • All routine maintenance, including GC column replacement, can be achieved without shutting down the system


Performance

  • Excellent long-term stability and equimolarity
  • Heavy duty insulation to maintain furnace temperature at 950°C leading to improved temperature accuracy across the whole furnace
  • Integrated filters to purify incoming gases boosting data integrity
  • Standalone automated pressure and leak check to guarantee leak-free performance
  • For sulfur analysis, system choice of oxygen or air as an oxidant based on laboratory need

Turnkey Solutions

  • ASTM D5504: Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence
  • ASTM D5623: Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7011: Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7807: Determination of Boiling Range Distribution of Hydrocarbon and Sulfur Components of Petroleum Distillates by Gas Chromatography and Chemiluminescence Detection
  • Custom Application like carbonyl sulfide in propylene gas, nitric oxide in ethylene and more
Features

Maintenance and Ease of Use

  • Ingenious G-Cal Service module used for testing the function of the detector without disassembling the configuration
  • Simplified preventative maintenance with removable panels and fast ceramics replacement
  • 7” Touchscreen interface providing both standalone operation and providing insight into your detector diagnostics and error logs
  • Able to be installed on most manufacturers GCs
  • All routine maintenance, including GC column replacement, can be achieved without shutting down the system


Performance

  • Excellent long-term stability and equimolarity
  • Heavy duty insulation to maintain furnace temperature at 950°C leading to improved temperature accuracy across the whole furnace
  • Integrated filters to purify incoming gases boosting data integrity
  • Standalone automated pressure and leak check to guarantee leak-free performance
  • For sulfur analysis, system choice of oxygen or air as an oxidant based on laboratory need

Turnkey Solutions

  • ASTM D5504: Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence
  • ASTM D5623: Sulfur Compounds in Light Petroleum Liquids by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7011: Determination of Trace Thiophene in Refined Benzene by Gas Chromatography and Sulfur Selective Detection
  • ASTM D7807: Determination of Boiling Range Distribution of Hydrocarbon and Sulfur Components of Petroleum Distillates by Gas Chromatography and Chemiluminescence Detection
  • Custom Application like carbonyl sulfide in propylene gas, nitric oxide in ethylene and more

Related Products

The Herzog 915 & 917 Gum Testers are designed to measure evaporation residue in aviation fuels, motor gasolines, and other volatile distillates.
PAC’s AC offers full range of Detailed Hydrocarbon Analyzers (DHA) to determine individual hydrocarbon composition in light hydrocarbon streams, gasoline blending feedstocks, spark ignition engine fue
The Alcor Intelligent Heater Tube™ (IHT) ensures traceable, accurate, and secure jet fuel thermal oxidation testing.
ElemeNtS is the most advanced, modular, analytical system which detects Total Sulfur and/or Total Nitrogen efficiently using Ultraviolet Fluorescence (UVF) and Chemiluminescence (CLD) in solid, liquid
The next generation Cold Filter Plugging Point analyzer combines a patented built-in cooling system and highly precise detection mechanism into an ultra-compact, easy to use instrument.
ISL’s OptiCPP performs pour and/cloud point testing of any petroleum products, down to -95°C (-139°F), in accordance with all international standards.
The AC Analytical Controls® standard solutions cover a wide spectrum of petroleum, petrochemical, and natural gas analysis needs.
OptiFlash Tag & Abel detect flashpoints from -30C to 120C for petroleum products, alcohols, solvents, chemicals, food and beverages.
Alcor’s MCRT-160 provides safe measurements of petroleum products with a tendency to thermally degrade and form coke under high temperature pyrolyzing conditions.
The VIDA ML density meter is specifically designed for mobile laboratory applications providing accurate and repeatable density.

How can we help?

You may contact our specialists by accomplishing form below.

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

SeNSe²
Sulfur Nitrogen Selective Detector
SeNSe²
Sulfur Nitrogen Selective Detector