HPLC for today and tomorrow

[Outstanding Performance]

Two performance capabilities supporting data reliability: excellent reproducibility made possible by the pump and autosampler and excellent stability of the column oven and detector.

[Easy-to-use]

Along with simple operation and ease of use, Chromaster offers ease of maintenance, a critical requirement for HPLC.

[Robustness]

Hitachi's reputation for instrument robustness and reliability continues with the Chromaster, which is built using stronger materials and manufactured with Hitachi's strict quality control standards.

Features

Features

-

*1:Optional

-

*1:Optional

*2: Autosamplers with or without thermostat are available

*3: Pumps with or without Auto-purge valve are available

-

Module lineup

Pump

5110: Pressure up to 40 MPa
5160: Pressure up to 60 MPa

Basic UHPLC models with a wide range of HPLC application
Item 5110 5160
Operating flow late range 0.001 to 9.999 mL/min 0.001 to 5.000 mL/min
Maximum operating pressure 40 MPa (0.001 to 5.000 mL/min)
20 MPa (5.001 to 9.999 mL/min)
60 MPa (0.001 to 2.500 mL/min)
30 MPa (2.501 to 5.000 mL/min)
Dimensions 340(W) × 440(D) × 140(H) mm
Number of mixed solvents*1 Up to 4

*With low pressure gradient unit (optional)

Autosampler

5260: Withstand pressure 60 MPa, Loop injection method
5280: Withstand pressure 60 MPa, Direct injection method

Product lineup to accommodate various applications
Item 5260 5280
Sample injection system Loop injection method (Cut injection, All volume injection, Full loop injection method) Direct injection method
Withstand pressure 60 MPa 60 MPa
Washing function Equipped with built-in washing pump
Two-solvent washing function
Wash solvent delivery by a syringe
Sample rack temperature control 1 to 45 °C 1 to 35 °C
(Temperature setting range) Capable of cooling and heating Cooling only
Sample capacity Standard 120 × 1.5 mL 200 × 1.5 mL
Optional 72 × 4 mL 128 × 4 mL

Column Oven

5310: Horizontal type
6310: Vertical type

Easily accommodates a 300-mm analytical column fitted with a guard-column
Item 5310 6310
Temperature setting range 1 to 85 °C (1 °C step) 4 to 90 °C (1 °C step)
Temperature control range [Ambient temperature -15 °C] to [Ambient temperature +60 °C] and range of the temperature setting [Ambient temperature -15 °C] to [Ambient temperature +75 °C] and within temperature setting range
Column capacity 300 mm × 3 (Maximum)
Built-in 3-liter water tank Available
Dimensions 410(W) × 440(D) × 140(H) mm 165(W) × 515(D) × 689(H) mm (Legs are not included)

Detector

5410: UV Detector
5420: UV-Vis Detector
5430: Diode Array Detector
5440: Fluorescence Detector
5450: RI Detector
5610: MS Detector

Item 5410 UV Detector 5420 UV-Vis Detector 5430 Diode Array Detector
Optical system Double-beam ratio photometric system Single-beam ratio photometric system
Wavelength range 190 to 600 nm 190 to 900 nm 190 to 900 nm
Flow cell Optical path length 10 mm
Simultaneous measurement Two-wavelength* spectrum acquisition
Dimensions 340(W) × 440(D) × 140(H) mm

*Please contact us for details.

Item 5440 Fluorescence Detector
Light source Xe lamp, Hg lamp for checking wavelength
Wavelength range Ex: 200 to 850 nm
Em: 250 to 900 nm (Change photomultiplier at 731 nm or more)
Flow cell Irradiation volume 12 µL
Dimensions 340 (W) × 440 (D) × 280 (H) mm
Item 5450 RI Detector
Refractive index range 1 to 1.75
Temperature control range OFF, and 30 to 50 °C
Dimensions 340 (W) × 440 (D) × 140 (H) mm, excluding projections
Item 5610 MS Detector
Measurement mass range (m/z) 20 to 1,000
Ion source Electrospray ionization (ESI)
Dimensions 440 (W) × 610(D) × 430 (H) mm
N2 gas usage Max flow rate 3.4 L/min, Pressure 300 ± 20 kPa

Organizer

Item Organizer
Output power DC24 V, 450 W
Supplies power to one pump, one autosampler, one detector (UV detector, UV-Vis detector, Diode array detector, or RI detector), and one interface control board
Bottle capacity and space 1.0 L bottle × 6 and 500 mL bottle × 3(Maximum), 314(W) × 280.8(D) mm
Dimensions 340 (W) × 420 (D) × 200 (H) mm

Data

System Performance

Analysis Example from the Chromaster 60 MPa System

The 60 MPa system, which can be used with columns containing 2.0 µm or smaller particles, and core-shell columns, is capable of conventional HPLC analysis and also ensures improved resolution performance and shorter analysis time.

-
Conditions
Sample Alkylphenones
Column LaChrom II C18 (5 µm) 4.6 mm I.D. × 150mmL
LaChromUltra II C18 (1.9 µm) 2.0 mm I.D. × 50 mmL
Column temperature 40 °C
Mobile phase A: H2O, B: CH3CN
Gradient mode High Frequency Mode
Wavelength 247 nm

The following options are used with UHPLC column:

  • Low dispersion piping kit
  • Semi-micro mixer (200 µL)
  • Semi-micro flow cell unit

Example of Carry-over analysis (5260)

Even when highly adsorbing Chlorhexidine is analyzed, the carry-over is extremely low.

-
-

Easy to use

Analysis Example from the Chromaster 60 MPa System

Most optional accessories are internally mounted to reduce the HPLC system’s height. The handle located on the front side of the organizer moves vertically for easy access to solvent bottles.

-

Module operations and the replacement of consumable and maintenance parts can be performed from the front side.

-

With attention to detail on the housing of tubes and wires, the system keeps tubes from getting tangled up, ensures the ease of replacement, and provides adequate seismic stability.

-
-

Column management system (optional)

Hitachi’s column management system can manage the Log information on analytical columns and guard columns from any manufacturer.
Log information can be written and read through a connector mounted on the column oven or USB port in the computer. ID Tags can be used repeatedly*.

*Approximate read/write life time : 100,000 times

-
-

Wakeup (automatic pre-analysis tasks) and Sleep (automatic post-analysis tasks) programs

Automatic system Wakeup and Sleep from GUI

  • In Conditioning, up to 10 programs can be created by combining any of the module settings, such as pre-analysis tasks of system (Wakeup), and post-analysis tasks of system (Sleep).
  • For Wakeup program ending time, you can specify any time on current day, the following day, or two days later.
  • The Sleep program starts at a specified time on the current day/the following day, or after the end of a continuous analysis run.

Automated system standby can reduce the amount of time required to make preparations for an analysis run.

-

Pharmaceutical

Food

Environment

NOTE:
These data are an example of measurement; the individual values cannot be guaranteed.
The system is for research use only, and is not intended for any animal or human therapeutic or diagnostic use.

Related Products

The LA-960 combines the most popular modern sizing technique with state of the art refinements to measure wet and dry samples measuring 10 nanometers to 5 millimeters.
The Automatic Titrator has an 8.4-inch LCD touch panel, adjustable angles, USB data management, a thermal printer, and supports up to four simultaneous titrations.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
Your lab-in-a-pocket. Horiba LAQUAtwin’s unique pocket meter integrates the electrode, display and sample container to enable simple, effective on-site testing by direct measurement from a single drop
Vaporizers efficiently measure moisture in solid and powdered samples, including resin pellets, medicines, inorganic powders, granules, and copy machine toner.
Hitachi offers high-precision background correction and high-sensitivity measurement by employing the polarized Zeeman correction method alongside the dual detector method.
Next evolution of micro-X-ray fluorescence spectroscopy ultimate performance in speed and flexibility
The Iridia Laser Ablation System​ is a purpose-built laser ablation system designed for ultimate flexibility and capable of addressing an increasing range of demanding applications.
A highly advanced analyzer solves the mysteries of the nano-world. A single device analyzes the three parameters that characterize nanoparticles: particle size, zeta potential, and molecular weight.

How can we help?

You may contact our specialists by accomplishing form below.

Website menu

Download catalog

To download e-catalog, please submit your details below.

Hamamatsu Failure Analysis

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire About this Product

You may contact our specialists by accomplishing form below.

Chromaster
HPLC
Chromaster
HPLC