The AQUATek LVA is a fully automated system for water analysis using purge and trap concentration. It ensures compliance with USEPA methods for VOCs through a closed-system design and vial cooling, preserving sample integrity and reducing VOC loss. Featuring a compact, stackable design, it integrates seamlessly with compatible concentrators like the Lumin or Stratum PTC, with a cleanup cycle using 90°C water for efficient maintenance.

The AQUATek LVA is a fully automated system for water analysis using purge and trap concentration. It ensures compliance with USEPA methods for VOCs through a closed-system design and vial cooling, preserving sample integrity and reducing VOC loss. Featuring a compact, stackable design, it integrates seamlessly with compatible concentrators like the Lumin or Stratum PTC, with a cleanup cycle using 90°C water for efficient maintenance.

Features

  • Sample Loop – The AQUATek LVA is equipped with a fixed volume PEEK™ sample loop with volume choices of 5, 10, 20 and 25 mL. The sample loop is filled with a liquid sample from the sample vial via a pressurization step. The loop is connected to two 3-port solenoid valves. These valves allow for the sample volume to be swept to the concentrator for analysis and allow for cleanup of the loop between samples via hot water rinsing and an inert gas sweep.​
  • 84-Position Sample Tray – The 84-position sample tray loads quickly and is fully insulated, ensuring that chilled samples remain cool.​
  • Vial Chiller Tray – The vial chiller allows for sample cooling. The chiller requires the use of an external recirculating cooling bath (optional accessory) for operation.​
  • Valve Manifold – A precision-machined manifold reduces plumbing connections by 60% over previous designs and results in improved system reliability.
  • Hot Water Rinsing – The entire liquid pathway can be rinsed using the high temperature Deionized (DI) water cleaning technique which uses two internal reservoirs to heat blank water to 90 °C for rinsing.​
  • XYZ Automation – The quick, whisper-quiet arm has undergone years of refinement and testing to eliminate the issues typically associated with older XYZ autosampler platforms.​
  • Stackable Configuration – Stackable configuration minimizes the instrument footprint and saves lab bench space.​
  • Internal Standards – ​Internal standards/surrogates are stored in two 15 mL amber glass vessels to prevent transmission of UV radiation. Vessels are sealed with a PEEK™ cap to prevent adsorption and contamination of the standard solution.  Each standard vessel can deliver volumes of 1, 2, 5, 10, or 20 μL to each sample. Each standard injection valve can be used independently or in combination.​
  • Barcode – The AQUATek LVA has the ability to connect to a standard barcode reader in order to scan vial barcodes and automatically have the vial ID number added into the TekLink™ schedule.​
  • Blanking Water Reservoir – Reservoir included with system provides cleanup water and auto-blanking, which frees up vial space in the sample tray for increased throughput.​​

Related Products

STA (simultaneous thermogravimetric analysis) measures DSC and TGA simultaneously in a single unit.
STA (simultaneous thermogravimetric analysis) measures DSC and TGA simultaneously in a single unit.
The UH5300 is controllable through a tablet terminal (iPad or Windows 10) offering new levels of access, control, and operation.
The UH5300 is controllable through a tablet terminal (iPad or Windows 10) offering new levels of access, control, and operation.
High-Performance Liquid Chromatography (HPLC) is utilized in a wide range of fields, such as medicine, food production, chemistry, and environmental science, making the demand for HPLC systems higher
High-Performance Liquid Chromatography (HPLC) is utilized in a wide range of fields, such as medicine, food production, chemistry, and environmental science, making the demand for HPLC systems higher
The Coulometric Karl Fischer Titrator offers an 8.4-inch touch LCD, adjustable display angles, USB data management, a thermal printer, and simultaneous measurement of up to 4 moisture types.
The Coulometric Karl Fischer Titrator offers an 8.4-inch touch LCD, adjustable display angles, USB data management, a thermal printer, and simultaneous measurement of up to 4 moisture types.
The Lotix Combustion TOC analyzer is designed to accurately measure carbon content in aqueous matrices down to the ppb level.
The Lotix Combustion TOC analyzer is designed to accurately measure carbon content in aqueous matrices down to the ppb level.
The Automatic Titrator has an 8.4-inch LCD touch panel, adjustable angles, USB data management, a thermal printer, and supports up to four simultaneous titrations.
The Automatic Titrator has an 8.4-inch LCD touch panel, adjustable angles, USB data management, a thermal printer, and supports up to four simultaneous titrations.
Optimise sample preparation with SimPrep. Perform dilutions, dosing, and standard additions with precision, staying within 1% of the target volume.
Optimise sample preparation with SimPrep. Perform dilutions, dosing, and standard additions with precision, staying within 1% of the target volume.
Compact, affordable, and versatile with a 4.3-inch touch panel, titration display, USB saving, and upgradeable from COM-28 to COM-28S.
Compact, affordable, and versatile with a 4.3-inch touch panel, titration display, USB saving, and upgradeable from COM-28 to COM-28S.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

AQUATek LVA
VOC
AQUATek LVA
VOC