Park NX10 is a flagship atomic force microscope (AFM) designed for small-sample research, delivering unmatched accuracy, reliability, and ease of use. As Park Systems’ original small-sample AFM, it has earned global recognition in both academic and industrial laboratories for producing precise, repeatable nanoscale measurements.

Park NX10 is a flagship atomic force microscope (AFM) designed for small-sample research, delivering unmatched accuracy, reliability, and ease of use. As Park Systems’ original small-sample AFM, it has earned global recognition in both academic and industrial laboratories for producing precise, repeatable nanoscale measurements.

Park NX10 Atomic Force Microscope – Sigmatech Inc. – AFM Philippines

Park NX10 is a flagship atomic force microscope (AFM) designed for small-sample research, delivering unmatched accuracy, reliability, and ease of use. As Park Systems’ original small-sample AFM, it has earned global recognition in both academic and industrial laboratories for producing precise, repeatable nanoscale measurements.

At the core of the NX10 are Park’s proprietary orthogonal scan system and True Non-contact™ mode, innovations that virtually eliminate lateral motion artifacts while protecting both tip and sample. Together, these technologies ensure artifact-free, high-resolution imaging even for the most delicate or challenging samples.

From materials science to polymers and bioengineering, NX10 delivers robust performance and dependable results, making it a trusted platform for advanced nanoscale metrology.

Key Features

NX10 AFM internal structure showing key components including on-axis optical microscope, AFM head with Z scanner, and XY stage

Outstanding NX Mechanical Design​

NX10 is built around improved XY and Z scanner performance. This includes fast Z-servo speed, which gives quick vertical response, and improved Z scan straightness for accurate imaging. In addition, the XY scanner ensures precise positioning during scans.​

Another highlight is the low Z detector noise. Thanks to the stacked piezo actuator and strain gauge sensor, the NX provides both high precision and exceptionally low noise levels, which are critical for reliable measurements. Together, these features make the NX series a robust and precise platform for advanced AFM research.​

Fast Z Servo and High Resolution

The resolution of the images in Park NX series has been further enhanced. The NX Z scanner, built with a stacked piezo actuator and a strain gauge sensor, delivers fast and precise measurements across a wide range of surfaces. From extremely flat to rough samples, it maintains consistent roughness linearity regardless of scan size, ensuring reliable results in any measurement.

Park Systems NX10 Atomic Force Microscope with fast Z servo and high-resolution scanning capability

NX Laser Beam Path

The NX head integrates a superluminescent diode that provides low coherence illumination, minimizing interference for stable signal detection. The laser beam is guided through precision mirrors to the cantilever and position-sensitive photodetector (PSPD), ensuring accurate signal alignment.

The knobs move the laser beam directly along the X and Y axes, allowing intuitive adjustment of the beam position and effortless realignment during probe replacement.

NX10 AFM laser beam path and optics alignment for precise tip positioning

Pre-Mounted Probe

AFM probe exchange can be challenging, even for experienced users, often resulting in cantilever breakage. Park AFM addresses this by using pre-aligned probe chip carriers with kinematic mounting points, ensuring reliable and consistent tip positioning.

The NX head Z scanner features three precision balls for kinematic mounting, complemented by magnets at the base to ensure a secure, reliable, and repeatable mounting position.

NX10 AFM Probe Chip Carrier
NX10 AFM pre-mounted probe design enabling easy tip installation

Improved Z Scan Straightness

Park NX series Z scanner maintains straightness within 0.1% across the usable range, with out-of-axis motion under 5 nm even at a full 15 µm extension. ​

Its compact assembly, combining a preload spring, kinematic pin, and piezo actuator, minimizes drift and ensures accurate vertical motion for reliable, distortion-free nanoscale measurements.

Comparison of Z scan straightness between NX10 AFM and conventional systems
NX10 AFM Z scanner image showing improved vertical linearity and low distortion

Simple Expansion Slot for Modes and Options

Simply plug an option module into the expansion slot to enable advanced AFM modes. Park NX series AFM features a modular design, ensuring compatibility with options across its product line.

NX10 modular expansion slot for additional AFM modes and accessories

On-Axis Optical Microscope

The high-power on-axis optical microscope provides a clear view of the sample surface. A software-controlled LED light source illuminates the sample surface for better observation.

NX10 on-axis optical microscope for real-time sample observation

Park AFM Technology

Orthogonal Scan System

Conventional AFMs with tube scanners suffer from out-of-plane motion and axes crosstalk, resulting in image distortion, especially over large scan areas. NX10, like all Park AFMs, employs an advanced orthogonal scan system featuring a flexure-guided architecture: a 2D flexure scanner moves the sample in the XY plane, while a separate 1D flexure scanner independently controls the probe’s Z-axis motion. This separated scanner system ensures highly orthogonal, linear scans with minimal out-of-plane motion and fast dynamic performance.

NX10 orthogonal scan system ensuring accurate XY motion and reduced crosstalk

The XY scanner is designed to achieve flat, purely horizontal motion without vertical interference by using stacked piezo actuators and  flexure hinge structures. A position sensor is located at the center of  the scanner to provide direct feedback for servo control, minimizing  positioning errors across the scan area. This design ensures consistent accuracy and stability, even when scanning large samples. 

NX10 Inside View of XY Scanner

Park AFM Technology

True Non-Contact™ Mode

NX10 features True Non-contact™ mode, a proprietary technology exclusively offered by Park Systems. True Non-contact mode obtains topography by detecting the attractive van der Waals force between the AFM tip and the sample surface.

Read More on Mode Notes →

Park NX10 Atomic Force Microscope  AFM Philippines

For more information, contact us.

Related Products

The only scanning Auger nanoprobe in the world that guarantees a field emission electron source whose spatial resolution is 8 nm or less.
The only scanning Auger nanoprobe in the world that guarantees a field emission electron source whose spatial resolution is 8 nm or less.
A high‑performance benchtop FTIR, the IR5 is ideal for everyday analysis, delivering fast and accurate IR measurements.
A high‑performance benchtop FTIR, the IR5 is ideal for everyday analysis, delivering fast and accurate IR measurements.
Seiwa Wafer review system visually inspects the defect location detected from AOI systems. This review system is able to capture the visual data and add it to previous inspection results.
Seiwa Wafer review system visually inspects the defect location detected from AOI systems. This review system is able to capture the visual data and add it to previous inspection results.
Ethos offers powerful solutions integrated into a single platform including low-acceleration Ar/Xe ion-beam processing when configured as a Triple-Beam system.
Ethos offers powerful solutions integrated into a single platform including low-acceleration Ar/Xe ion-beam processing when configured as a Triple-Beam system.
The Quorum K975X Turbo-Pumped Thermal Evaporator is a high vacuum evaporator for TEM, SEM and thin film applications.
The Quorum K975X Turbo-Pumped Thermal Evaporator is a high vacuum evaporator for TEM, SEM and thin film applications.
The IM4000Plus Ion Milling System utilizes a broad, low-energy Ar+ ion beam milling method to produce wider, undistorted cross-section milling or flat milling.
The IM4000Plus Ion Milling System utilizes a broad, low-energy Ar+ ion beam milling method to produce wider, undistorted cross-section milling or flat milling.
With options for both oxidizing and non-oxidizing metals, as well as carbon evaporation, Quorum coaters are suitable for applications, including high-resolution SEM and FIB-SEM, ensuring precise resu
With options for both oxidizing and non-oxidizing metals, as well as carbon evaporation, Quorum coaters are suitable for applications, including high-resolution SEM and FIB-SEM, ensuring precise resu

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

Park NX10
Small Sample Atomic Force Microscope
Park NX10
Small Sample Atomic Force Microscope