Carbon/Sulfur Analyzer

EMIA-Step

The EMIA-Step Carbon/Sulfur Analyzer, which uses a tubular electric resistance heating furnace, offers highly accurate and sensitive analysis. Its variable heating temperature (up to 1450°C)  function allows for quantitative analysis by separating it by temperature or humidity as well as whole quantity analysis.

The EMIA-Step Carbon/Sulfur Analyzer, which uses a tubular electric resistance heating furnace, offers highly accurate and sensitive analysis. Its variable heating temperature (up to 1450°C)  function allows for quantitative analysis by separating it by temperature or humidity as well as whole quantity analysis.

The EMIA-Step Carbon/Sulfur Analyzer, which uses a tubular electric resistance heating furnace, offers highly accurate and sensitive analysis. Its variable heating temperature (up to 1450°C)  function allows for quantitative analysis by separating it by temperature or humidity as well as whole quantity analysis.

* For samples which is difficult to burn (e.g. ceramics, Ti alloys, etc), we also offer the EMIA-Pro (Entry model) and EMIA-Expert (Flagship High-Accuracy Model).

Greater Accuracy

Proven NDIR Gas Detection Technology

The EMIA-Step Carbon/Sulfur Analyzer uses the infrared method to measure Carbon and Sulfur after combustion in an electric resistance furnace. With HORIBA’s renowned Non-Dispersive Infrared (NDIR) measurement capabilities, it can detect carbon ranging from 0.0003 to 6.0% (m/m) and sulfur ranging from 0.0004 to 1.0% (m/m). The analyzer is also equipped with a unique CO detector and can be used for a wide range of inorganic materials, including steel, cokes, catalysts, non-ferrous alloys like aluminum, and lithium-ion battery materials.

Please also refer the Measurement Principle page for the details.


 

Temperature Control Function

The combustion furnace of the analyzer utilizes a distinctive sealed system, which facilitates efficient combustion of flame-retardant samples through high-pressure oxygenation. The system offers excellent temperature stability, ensuring consistent performance across low and high temperatures. This broadens the range of applications to samples containing substances that are easily decomposed and burned at low temperatures. The decomposition combustion of organic and inorganic matter can be easily observed.



 Temperature rise control from 300 °C to 900 °C


Improved Measurement and Maintenance Efficiency

New dust-filter provides easy maintenance capability

The EMIA-Step features a dust-filter mechanism that has been proven effective in high frequency induction heating models. The filter unit collects dust generated by high-temperature combustion to prevent it from adhering to the piping after the combustion furnace. This reduces the adsorption of CO2 and SO2 gases by dust and ensures highly accurate and sensitive analyses.



Schematic of tubular electric resistance heating furnace

High Throughput

The EMIA Series can complete one measurement cycle, measurement-display result-cleaning, in 70 seconds (i.e. about 50 samples/hour).

Gas Collection Mode

Our exclusive furnace features a closed structure that enables efficient combustion under high-pressure oxygen and allows for the burning of high melting point materials. This unique furnace design allows Gas Collection analysis, in which small amounts of gases are captured within the furnace and then transferred to the detector for analysis.


More Intuitive Software for Easy Operation

Advanced Operation Software

The EMIA Series features its own proprietary operating software, which has been designed with a focus on ease of use, optimizing layout, operating menus, and functions for enhanced user-friendliness.

Enhanced Operator Assistance

Additionally, the software includes a self-diagnostic monitoring feature to assess the status of connected devices, an alarm function, and three navigators to recommend the most suitable conditions for samples, troubleshoot errors, and alert users to perform maintenance. These features improve daily operation and ensure efficient analysis.

*The user interface and functionalities of the software for this system are the same with those of EMIA-Pro

Detection methodNDIR (Non-Dispersive InfraRed) 
Required sample amount1.00 ± 0.10 g
Minimum reading0.000001% (m/m) for both Carbon and Sulfur
CarbonMeasurement range0.0003 〜 6.0% (m/m) 
Accuracy (Repeatability)σn-1 ≦ 0.00015% (m/m) or RSD ≦ 0.75%
SulfurMeasurement range0.0004 〜 1.0%(m/m)
Accuracy (Repeatability)σn-1  ≦ 0.00020% (m/m) or RSD ≦ 2.00%
Setting temperature range0 (room temperature) – 1450℃
Dimensions [ W x D x H ]Combustion unit: 443 × 725 × 710 mm
Measurement unit : 271 × 725 × 710 mm
MassCombustion unit: 77 kg,  Measurement unit : 53 kg
Power200/220/240 V, 5 kVA *Excluding peripheral devices
Carrier gasOxygen: Purity 99.5%, Pressure: 0.30〜0.33 MPa
Operation gasNitrogen: Purity 99.5%, Pressure: 0.35〜0.38 MPa
*Dry air excluding moisture and oil content can be used as the operation gas
 only for the standard model
Data processing and operationPC with Windows® 10
User interfaceTouch panel/Keyboard/Mouse

Related Products

A rugged, lightweight handheld XRF analyzer range delivering fast, accurate, and non-destructive elemental analysis for metals, alloys, soils, minerals, polymers, and other materials.
A rugged, lightweight handheld XRF analyzer range delivering fast, accurate, and non-destructive elemental analysis for metals, alloys, soils, minerals, polymers, and other materials.
Offers trapping benefits that have never been seen before by Purge and Trap concentrators.
Offers trapping benefits that have never been seen before by Purge and Trap concentrators.
Offers accurate and reliable particle size analysis in a compact, easy-to-use system ideal for laboratory and quality control applications.
Offers accurate and reliable particle size analysis in a compact, easy-to-use system ideal for laboratory and quality control applications.
Designed for high-accuracy absorbance measurements and spectral analysis of materials, chemicals, and research samples.
Designed for high-accuracy absorbance measurements and spectral analysis of materials, chemicals, and research samples.
The QuickTrace® M-7600 delivers ultra-trace mercury detection (<0.5 ng/L) for water, soil, and biological samples.
The QuickTrace® M-7600 delivers ultra-trace mercury detection (<0.5 ng/L) for water, soil, and biological samples.
The Teledyne LABS ASXpress® Plus Rapid Sample Injection System reduces the time required for autosampler movement, sample uptake, stabilization, and rinse operations with ICP-OES and ICP-MS. The resul
The Teledyne LABS ASXpress® Plus Rapid Sample Injection System reduces the time required for autosampler movement, sample uptake, stabilization, and rinse operations with ICP-OES and ICP-MS. The resul
The device features an easy-to-read color touch panel and one-handed precision dispensing for manual titration, with three dripping methods: Touch Panel Start, remote switch, and INCREMENT knob for mi
The device features an easy-to-read color touch panel and one-handed precision dispensing for manual titration, with three dripping methods: Touch Panel Start, remote switch, and INCREMENT knob for mi
Fast and Reliable Benchtop XRF for Elemental Analysis and Quality Control
Fast and Reliable Benchtop XRF for Elemental Analysis and Quality Control

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

EMIA-Step
Carbon/Sulfur Analyzer
EMIA-Step
Carbon/Sulfur Analyzer