The HORIBA Partica mini LA-350 offers accurate and reliable particle size analysis in a compact, easy-to-use system ideal for laboratory and quality control applications. Using advanced laser diffraction technology, it measures particles from submicron sizes up to several hundred micrometers with excellent repeatability.

Based on the principle that particle size determines the angle of scattered light—larger particles scatter at smaller angles while smaller ones scatter at wider angles—the LA-350 analyzes the intensity and pattern of scattered light to deliver precise particle size distribution results.

The HORIBA Partica mini LA-350 offers accurate and reliable particle size analysis in a compact, easy-to-use system ideal for laboratory and quality control applications. Using advanced laser diffraction technology, it measures particles from submicron sizes up to several hundred micrometers with excellent repeatability.

Based on the principle that particle size determines the angle of scattered light—larger particles scatter at smaller angles while smaller ones scatter at wider angles—the LA-350 analyzes the intensity and pattern of scattered light to deliver precise particle size distribution results.

Features

Performance that matters

  • Measure particle size between 10 nanometers and 5 millimeters
  • State of the art nanoparticle measurement resolves peaks at 30 nanometers
  • Suitable for suspensions, emulsions, powders, pastes, gels, and creams
  • Easy to use dry powder accessory, read the PowderJet page for more information
  • Requires only micrograms* of sample, minimizing cost of analysis
  • Flexible, fully automated measurement sequences maximize precision and method compliance
  • Excellent reproducibility and unit-to-unit agreement, read the Gage R&R Study for more information
  • Measurements in less than 60 seconds boost productivity
  • Based on the ultra-durable LA-950 platform, noted for its reliability

Software that grows to meet your needs

  • New users are guided by the Method Expert software to create powerful measurement methods with no prior training
  • Experienced users create turn-key measurements with the Sequence function to include custom messages, measurement averaging, pass/fail repeats, and much more
  • Advanced users benefit the Intensity Graph, Custom Calculations, and other power tools to deeply understand their measurements
  • The brand new user interface emphasizes ease of use to ensure hassle-free operation
  • Integrated 21 CFR Part 11 compliant software available with user administration, audit trail, and electronic signature functionality

HORIBA’s performance guarantee

  • Guaranteed accuracy of ± 0.6%**
  • Excellent unit-to-unit precision, ideal for multi-location requirements
  • ISO 13320:2009 compliant
  • IQ/OQ available
  • LA-960 performance verified on every unit with NIST-traceable mono- and polydisperse size standards

Our particle expertise = your solution

HORIBA’s experienced staff of technical and applications specialists support the LA-960 in 54 offices across 45 countries. We are committed to the satisfaction of our users and to the education of the greater industry and provide many channels of support including:

  • Sample analysis via the many Applications Labs around the world
  • Free software updates, webinars, technical notes, and much more in the Download Center
  • Instant support via phone, e-mail, and online meeting
  • On-site and in-house user training courses
  • Service contracts, verifications, and validations to fit every requirement
  • Advanced software tools to correlate data from other particle size analyzers to maintain historic specifications

Applications

Watch a two minute video detailing how HORIBA Scientific has partnered with Particle Sciences to provide world-class technology and support for their CDMO business.

Video interview with Rob Lee of Particle Sciences

Brochures

LA-960 – Simple, Powerful, Reliable Particle Size Analysis

HORIBA Particle Characterization Lineup

A Guidebook to Particle Size Analysis

Downloads

Why HORIBA Particle Characterization?

The Method Expert – Guided, Automated Method Development (registration required)

Optimization of Dry Powder Particle Size Analysis (registration required)

The HORIBA Guidebook to Particle Size Analysis

LA-960 Result Interpretation Quick Reference

Browse through our extensive collection of Technical Notes, recorded Webinars, and much more in the Download Center.

Resources

LA-960 Performance – Precision – A 40-unit Reproducibility Study

Related Products

Offers high cost-performance solution for users who require less measurement range and accuracy.
Offers high cost-performance solution for users who require less measurement range and accuracy.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
The Hitachi HPLC/UHPLC systems continue to set market standards for performance and reliability in both conventional and high-pressure chromatography.
Uses temperature control to produce accurate measurement results for a variety of samples.
Uses temperature control to produce accurate measurement results for a variety of samples.
The QuickTrace® M-7600 delivers ultra-trace mercury detection (<0.5 ng/L) for water, soil, and biological samples.
The QuickTrace® M-7600 delivers ultra-trace mercury detection (<0.5 ng/L) for water, soil, and biological samples.
Capturing particle size distribution and shape simultaneously to reduce measurement time, streamline R&D and QC workflows, and save lab space.
Capturing particle size distribution and shape simultaneously to reduce measurement time, streamline R&D and QC workflows, and save lab space.
DSC is used to measure heat flow for material characterization by providing thermal properties such as melting point, glass transition and crystallization.
DSC is used to measure heat flow for material characterization by providing thermal properties such as melting point, glass transition and crystallization.
The Automatic Titrator has an 8.4-inch LCD touch panel, adjustable angles, USB data management, a thermal printer, and supports up to four simultaneous titrations.
The Automatic Titrator has an 8.4-inch LCD touch panel, adjustable angles, USB data management, a thermal printer, and supports up to four simultaneous titrations.
Compact and fully automated, designed for high-performance confocal Raman imaging. Experience intuitive use with advanced spectral precision.
Compact and fully automated, designed for high-performance confocal Raman imaging. Experience intuitive use with advanced spectral precision.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

LA-350
Laser Diffraction Analyzer
LA-350
Laser Diffraction Analyzer