Oxygen/Nitrogen/Hydrogen Combustion Analyzer

EMGA-930

Horiba EMGA-930 is a simultaneous oxygen, nitrogen & hydrogen elemental analyzer with high accuracy and repeatability suiting to cutting-edge technology's R&D as well as quality control in the market of steel, new materials, catalyst and so on. This is a new generation model optimized to fit to user's requests.

Horiba EMGA-930 is a simultaneous oxygen, nitrogen & hydrogen elemental analyzer with high accuracy and repeatability suiting to cutting-edge technology’s R&D as well as quality control in the market of steel, new materials, catalyst and so on. This is a new generation model optimized to fit to user’s requests.

Principle and Gas flow diagram

The sample is placed in a graphite crucible and the crucible is maintained between the upper and the lower electrode of the impulse furnace.  A high current power passes through the crucible to create a high temperature.

The oxide in the sample reacts with the graphite crucible, and is extracted as carbon monoxide (CO), and carried together with the carrier gas. The extracted gas is directly analysed after the dust filter. According to the oxygen concentration, it is determined by CO or CO2 after pass throw oxidizer (Copper Oxide) with a non dispersive Infra-Red analyser (NDIR).

The Hydrogen is determined with a non dispersive Infra Red analyser as H2O after H2 passes through the oxidizer (Copper Oxide).

The Nitrogen in the sample is extracted as nitrogen gas (N2) and its concentration is determined by a thermal conductivity detector (TCD).


Super High Performance

Wide range and high accuracy measurement

*Range: Oxygen:
0-5%, Nitrogen: 0-3%, Hydrogen: 0-0.25%

*Accuracy:
σn-1≦0.3ppm or CV≦1.0% for STD sample
σn-1≦0.02ppm or CV≦0.5% for Reference gas

*Accuracy H:
σn-1≦0.04ppm or RSD≦2.0% for Reference gas

Double detectors of oxygen (CO and CO2), long type cell and optimized design of TCD provide wide range measurements.

Optimization of the signal processing reduces by half the electrical noise compared to conventional model.

Standard

EMGA fulfils requirements of the standard method for analysis of steel titanium, ceramics etc…

EX)
*ISO10720, ISO17053
*JIS G1228
*ASTM E1019, ASTM E1569, ASTM E1409


User-friendly Software

Measurement Window

Simple software allows easy handling.
Extracted gas signals are displayed in real time numerically and also as curves together with temperature level. Graphs are saved automatically.
In the measurement window, sample weight can be registered automatically. Results are saved in a data table for easy management.

HORIBA originality-Maintenance navigator

Maintenance counter informs users at the timing of consumables replacement to keep high accuracy means.
And as navigator describes the easy to understand procedure for the replacing parts, operator can do maintenance works with absolutely no experience and technical knowledge.

Related Products

VOC

VOC

The Teledyne Tekmar U-shaped trap offers trapping benefits that have never been seen before by Purge and Trap concentrators.
The Teledyne Tekmar U-shaped trap offers trapping benefits that have never been seen before by Purge and Trap concentrators.
With the highest level for 3D fluorescence spectra, F-7100 can be used in a wide range of applications from the cutting edge research to quality control.​
With the highest level for 3D fluorescence spectra, F-7100 can be used in a wide range of applications from the cutting edge research to quality control.​
Autotouch Hydraulic Presses are available in 8 Ton, 15 Ton, 25 Ton and 40 Ton load configurations.
Autotouch Hydraulic Presses are available in 8 Ton, 15 Ton, 25 Ton and 40 Ton load configurations.
Vaporizers efficiently measure moisture in solid and powdered samples, including resin pellets, medicines, inorganic powders, granules, and copy machine toner.
Vaporizers efficiently measure moisture in solid and powdered samples, including resin pellets, medicines, inorganic powders, granules, and copy machine toner.

VOC

VOC

The AQUATek LVA automates VOC water analysis, ensuring USEPA compliance and easy maintenance.
The AQUATek LVA automates VOC water analysis, ensuring USEPA compliance and easy maintenance.
​​​​​​​​The Analyte HE Laser Ablation System​​ offers excimer technology at 193 nm with all the analytical capabilities you require, delivering finely controlled, “homogenized-flat” ablations.
​​​​​​​​The Analyte HE Laser Ablation System​​ offers excimer technology at 193 nm with all the analytical capabilities you require, delivering finely controlled, “homogenized-flat” ablations.
DSC is used to measure heat flow for material characterization by providing thermal properties such as melting point, glass transition and crystallization.
DSC is used to measure heat flow for material characterization by providing thermal properties such as melting point, glass transition and crystallization.
Hitachi offers high-precision background correction and high-sensitivity measurement by employing the polarized Zeeman correction method alongside the dual detector method.
Hitachi offers high-precision background correction and high-sensitivity measurement by employing the polarized Zeeman correction method alongside the dual detector method.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

EMGA-930
Oxygen/Nitrogen/Hydrogen Combustion Analyzer
EMGA-930