Multirange Viscometer

HVM 472

ASTM D445, ASTM D446, IP 71, ISO 3104, ISO 3105, GOST 33, GB/T 265

The Herzog Multi-Range Viscometer HVM 472 determines direct kinematic viscosity of transparent and opaque liquids fully automated. The easy to operate viscometer includes 2 multi-range capillaries with 100 fold measuring range, requires only 18 ml, and delivers precise results. Its auto sampler offers truly continuous operation, spent sample vials automatically discharge, allowing new samples to be added at any time. For rapid analysis within viscosity range of 0.5 to 600mm2/s, the HVM 472 offers the smart alternative to run samples using 20-fold range Fast Run (FR) capillaries. The HVM 472 shows excellent precision and accuracy in full compliance with ASTM D445.

ASTM D445, ASTM D446, IP 71, ISO 3104, ISO 3105, GOST 33, GB/T 265

The Herzog Multi-Range Viscometer HVM 472 determines direct kinematic viscosity of transparent and opaque liquids fully automated. The easy to operate viscometer includes 2 multi-range capillaries with 100 fold measuring range, requires only 18 ml, and delivers precise results. Its auto sampler offers truly continuous operation, spent sample vials automatically discharge, allowing new samples to be added at any time. For rapid analysis within viscosity range of 0.5 to 600mm2/s, the HVM 472 offers the smart alternative to run samples using 20-fold range Fast Run (FR) capillaries. The HVM 472 shows excellent precision and accuracy in full compliance with ASTM D445.

  • Precise and accurate analysis results
  • Easy and safe operation with advanced system automation
  • Flexible and modular design for fast adaptation to both current & future analysis needs
  • Reduced VOC emissions with connection to ventilation system
  • Smart bath design since capillary tubes are visible from 360 direction
  • High quality and robust configuration with automated cleaning station using 2 different solvents and corrosion resistant material
  • Maximized sample throughput with two integrated sample changers for 7-8 hours unattended operation
  • User-friendly system control and analysis software

Related Products

PAC’s AC Analytical Controls offers the Hi-Speed Refinery Gas Analyzer, a high speed solution that determines and reports the composition of refinery gas streams in only five minutes.
PAC’s AC Analytical Controls offers the Hi-Speed Refinery Gas Analyzer, a high speed solution that determines and reports the composition of refinery gas streams in only five minutes.
The VIDA density meter provides accurate and repeatable density analysis for a wide range of liquids according to ASTM D4052.
The VIDA density meter provides accurate and repeatable density analysis for a wide range of liquids according to ASTM D4052.
The next generation Freeze Point Analyzer offers proven technology used by labs worldwide. The powerful internal cooling system can measure up to -100C (-148F) without the need of an external cooling
The next generation Freeze Point Analyzer offers proven technology used by labs worldwide. The powerful internal cooling system can measure up to -100C (-148F) without the need of an external cooling
Herzog’s HVP 972 Vapor Pressure Analyzer is the modern analytical instrument designed for accurate determination of vapor pressure.
Herzog’s HVP 972 Vapor Pressure Analyzer is the modern analytical instrument designed for accurate determination of vapor pressure.
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
The Reformulyzer M4’s short analysis time allows to run up to 100% more samples a day and it enables labs to comply to the significant in-tank and in-ship blending time constraints related to analysis
OptiDist is the benchmark in atmospheric distillation testing offering the highest level of precision. Its a state-of-the-art optimal solution for performing atmospheric distillation.
OptiDist is the benchmark in atmospheric distillation testing offering the highest level of precision. Its a state-of-the-art optimal solution for performing atmospheric distillation.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
Optiflash Cleveland Open Cup accurately detects flash point up to 400°C for petroleum products, lube oil, gear oil, food & beverages, chemicals, and fluxed bitumen.
PAC provides complete, turn-key gas chromatographic solutions for accurate determination of true boiling point data – from naphtha up to crude oil samples.
PAC provides complete, turn-key gas chromatographic solutions for accurate determination of true boiling point data – from naphtha up to crude oil samples.

Product added to Quote list ✔

failure analysis, material characterization, and metrology equipment

Subscribe to newsletter

Sign up for our newsletter to get updates on promos, seminars, events, products, application notes and more.

Inquire for this Product

HVM 472
Multirange Viscometer
HVM 472